170 research outputs found

    DGNSS Cooperative Positioning in Mobile Smart Devices: A Proof of Concept

    Get PDF
    Global Navigation Satellite System (GNSS) constitutes the foremost provider for geo-localization in a growing number of consumer-grade applications and services supporting urban mobility. Therefore, low-cost and ultra-low-cost, embedded GNSS receivers have become ubiquitous in mobile devices such as smartphones and consumer electronics to a large extent. However, limited sky visibility and multipath scattering induced in urban areas hinder positioning and navigation capabilities, thus threatening the quality of position estimates. This work leverages the availability of raw GNSS measurements in ultralow-cost smartphone chipsets and the ubiquitous connectivity provided by modern, low-latency network infrastructures to enable a Cooperative Positioning (CP) framework. A Proof Of Concept is presented that aims at demonstrating the feasibility of a GNSS-only CP among networked smartphones embedding ultra-low-cost GNSS receivers. The test campaign presented in this study assessed the feasibility of a client-server approach over 4G/LTE network connectivity. Results demonstrated an overall service availability above 80%, and an average accuracy improvement over the 40% w.r.t. to the GNSS standalone solution

    DXA-Based Detection of Low Muscle Mass Using the Total Body Muscularity Assessment Index (TB-MAXI): A New Index with Cutoff Values from the NHANES 1999–2004

    Get PDF
    The aims of this study were to investigate age-related changes in total body skeletal muscle mass (TBSMM) and the between-limb asymmetry in lean mass in a large sample of adults. Demographic, anthropometric, and DXA-derived data of National Health and Nutrition Examination Survey participants were considered. The sample included 10,014 participants of two ethnic groups (Caucasians and African Americans). The age-related decline of TBSMM absolute values was between 5% and 6% per decade in males and between 4.5% and 5.0% per decade in females. The adjustment of TBSMM for body surface area (TB-MAXI) showed that muscle mass peaked in the second decade and decreased progressively during the subsequent decades. The following thresholds were identified to distinguish between low and normal TB-MAXI: (i) 10.0 kg/m2 and 11.0 kg/m2 in Caucasian and African American females; and (ii) 12.5 kg/m2 and 14.5 kg/m2 in Caucasian and African American males. The lean asymmetry indices were higher for the lower limbs compared with the upper limbs and were higher for males compared with females. In conclusion, the present study proposes the TB-MAXI and lean asymmetry index, which can be used (and included in DXA reports) as clinically relevant markers for muscle amount and lean distribution

    Architectural changes in superficial and deep compartments of the tibialis anterior during electrical stimulation over different sites

    Get PDF
    Electrical stimulation is widely used in rehabilitation to prevent muscle weakness and to assist the functional recovery of neural deficits. Its application is however limited by the rapid development of muscle fatigue due to the non-physiological motor unit (MU) recruitment. This issue can be mitigated by interleaving muscle belly (mStim) and nerve stimulation (nStim) to distribute the temporal recruitment among different MU groups. To be effective, this approach requires the two stimulation modalities to activate minimally-overlapped groups of MUs. In this manuscript, we investigated spatial differences between mStim and nStim MU recruitment through the study of architectural changes of superficial and deep compartments of tibialis anterior (TA). We used ultrasound imaging to measure variations in muscle thickness, pennation angle, and fiber length during mStim, nStim, and voluntary (Vol) contractions at 15% and 25% of the maximal force. For both contraction levels, architectural changes induced by nStim in the deep and superficial compartments were similar to those observed during Vol. Instead, during mStim superficial fascicles underwent a greater change compared to those observed during nStim and Vol, both in absolute magnitude and in their relative differences between compartments. These observations suggest that nStim results in a distributed MU recruitment over the entire muscle volume, similarly to Vol, whereas mStim preferentially activates the superficial muscle layer. The diversity between spatial recruitment of nStim and mStim suggests the involvement of different MU populations, which justifies strategies based on interleaved nerve/muscle stimulation to reduce muscle fatigue during electrically-induced contractions of TA

    Characterization of the stimulation output of four devices for focal muscle vibration

    Get PDF
    Different devices for mechano-acoustic muscle vibration became available on the market in the last ten years. Although the use of these vibrators is increasing in research and clinical settings, the features of their stimulation output were never described in literature. In this study we aimed to quantify and compare the stimulation output of the four most widespread pneumatic devices for focal muscle vibration available on the market. A piezoelectric pressure sensor was used to measure the pressure profile generated by the four selected devices in the following experimental conditions: i) measurement of the output changes associated with variations of the stimulation amplitude for three stimulation frequencies (100 Hz, 200 Hz, and 300 Hz); ii) measurement of the output changes during a 20-min long stimulation at constant frequency (300 Hz) and amplitude; iii) measurement of the output changes associated with the progressive activation of all stimulation channels at constant frequency (200 Hz) for different amplitudes. The maximum peak-to-peak amplitudes of the pressure waves were in the range 102 mbar - 369 mbar (below the maximum values declared by the different manufacturers). The shape of the pressure waves generated by the four devices was quasi-sinusoidal and asymmetric with respect to the atmospheric pressure. All output features had a remarkable intra- and inter-device variability. Further studies are required to support the technological improvement of the currently available devices and to focus the issues of vibration effectiveness, limitations, proper protocols, modalities of its application and assessment in neuromuscular training and rehabilitation

    Diagnostic performance of the Strength and Pain Assessment (SPA) score for non-contact muscle injury screening in male soccer players

    Get PDF
    Objectives: The aims of this study were to develop a clinical-feature based scoring system for muscle injury screening and to assess its diagnostic accuracy when large number of injuries are suspected. Methods: A prospective diagnostic accuracy study was performed according to the Standards for Reporting of Diagnostic Accuracy (STARD) criteria. The diagnostic accuracy of the Strength and Pain Assessment (SPA) score (index test) was assessed in relation to muscle ultrasonography (reference standard). A large (n = 175) number of male soccer players met the inclusion/exclusion criteria: clinical assessment (i.e., evaluation of pain onset modality, location, distribution, impact on performance, and manual muscle strength testing) and ultrasonography were performed in all players after 48 hours from the sudden or progressive onset of muscle pain during or after a soccer competition. Results: 91 of 175 cases (52%) were classified as functional muscle disorders, while signs of muscle tear were observed in the remaining 84 of 175 (48%) cases that were classified as structural muscle injuries. The median (1st–3rd quartile) value of the SPA score was significantly (P < 0.001) lower in the functional disorder group [9 (9–10)] compared to the structural injury group [12 (12–13)]. The area under the Receiver Operating Characteristic curve for different cutoff points of the SPA score was 0.977 (95% confidence intervals: 0.957–0.998) and the optimal cutoff value of the SPA score providing the greatest sensitivity and specificity (respectively, 99% and 89%) was 11. Conclusion: This study found that the SPA score has high diagnostic accuracy for structural muscle injuries and could be used as a valid screening tool in soccer players presenting with sudden or progressive onset of muscle pain during or after a competition

    Cooperative Localization Enhancement through GNSS Raw Data in Vehicular Networks

    Get PDF
    The evolution and integration of communication networks and positioning technologies are evolving at a fast pace in the framework of vehicular systems. The mutual dependency of such two capabilities can enable several new cooperative paradigms, whose adoption is however slowed down by the lack of suitable open protocols, especially related to the positioning and navigation domain. In light of this, the paper introduces a novel vehicular message type, namely the Cooperative Enhancement Message (CEM), and an associated open protocol to enable the sharing of Global Navigation Satellite Systems (GNSS) raw measurements among connected vehicles. The proposed CEM aims at extending existent approaches such as Cooperative Awareness Messages (CAM) and Collective Perception Messages (CPM) by complementing their paradigms with a cooperative enhancement of the localization accuracy, precision, and integrity proposed by state-of-the-art solutions. Besides the definition of CEMs and a related protocol, a validation of the approach is proposed through a novel simulation framework. A preliminary analysis of the network performance is presented in the case where CEM and CAM transmissions coexist and are concurrently used to support cooperative vehicle applications
    • …
    corecore