1,626 research outputs found

    Modelling of gypsum and ice diapirs in the martian crust

    Get PDF

    An assessment of pulse transit time for detecting heavy blood loss during surgical operation

    Get PDF
    Copyright @ Wang et al.; Licensee Bentham Open. This is an open access article licensed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted, non-commercial use, distribution and reproduction in any medium, provided the work is properly cited.The main contribution of this paper is the use of non-invasive measurements such as electrocardiogram (ECG) and photoplethysmographic (PPG) pulse oximetry waveforms to develop a new physiological signal analysis technique for detecting blood loss during surgical operation. Urological surgery cases were considered as the control group due to its generality, and cardiac surgery as experimental group since it involves blood loss and water supply. Results show that the control group has the tendency of a reduction of the pulse transient time (PTT), and this indicates an increment in the blood flow velocity changes from slow to fast. While for the experimental group, the PTT indicates high values during blood loss, and low values during water supply. Statistical analysis shows considerable differences (i.e., P <0.05) between both groups leading to the conclusion that PTT could be a good indicator for monitoring patients' blood loss during a surgical operation.The National Science Council (NSC) of Taiwan and the Centre for Dynamical Biomarkers and Translational Medicine, National Central University, Taiwan

    Barriers and enablers to adherence to anticoagulation in heart failure with atrial fibrillation: patient and provider perspectives

    Full text link
    © 2017 John Wiley & Sons Ltd Aims & Objectives: The purpose of this study was to elucidate the barriers and enablers to adherence to anticoagulation in individuals with chronic heart failure (CHF) with concomitant atrial fibrillation (AF) from the perspective of patients and providers. Background: CHF and AF commonly coexist and are associated with increased stroke risk and mortality. Oral anticoagulation significantly reduces stroke risk and improves outcomes. Yet, in approximately 30% of cases, anticoagulation is not commenced for a variety of reasons. Design: Qualitative study using narrative inquiry. Methods: Data from face-to-face individual interviews with patients and information retrieved from healthcare file note review documented the clinician perspective. This study is a synthesis of the two data sources, obtained during patient clinical assessments as part of the Atrial Fibrillation And Stroke Thromboprophylaxis in hEart failuRe (AFASTER) Study. Results: Patient choice and preference were important factors in anticoagulation decisions, including treatment burden, unfavourable or intolerable side effects and patient refusal. Financial barriers included cost of travel, medication cost and reimbursement. Psychological factors included psychiatric illness, cognitive impairment and depression. Social barriers included homelessness and the absence of a caregiver or lack of caregiver assistance. Clinician reticence included fear of falls, frailty, age, fear of bleeding and the challenges of multimorbidity. Facilitators to successful prescription and adherence were caregiver support, reminders and routine, self-testing and the use of technology. Conclusions: Many barriers remain to high-risk individuals being prescribed anticoagulation for stroke prevention. There are a number of enabling factors that facilitate prescription and optimise treatment adherence. Nurses should challenge these treatment barriers and seek enabling factors to optimise therapy. Relevance to clinical practice: Nurses can help patients and caregivers to understand complex anticoagulant risk-benefit information, and act as a patient advocate when making complex stroke prevention decisions

    Atrial fibrillation and thromboprophylaxis in heart failure: The need for patient-centered approaches to address adherence

    Full text link
    Atrial fibrillation is a common arrhythmia in heart failure and a risk factor for stroke. Risk assessment tools can assist clinicians with decision making in the allocation of thromboprophylaxis. This review provides an overview of current validated risk assessment tools for atrial fibrillation and emphasizes the importance of tailoring individual risk and the importance of weighing the benefits of treatment. Further, this review provides details of innovative and patient-centered methods for ensuring optimal adherence to prescribed therapy. Prior to initiating oral anticoagulant therapy, a comprehensive risk assessment should include evaluation of associated cardiogeriatric conditions, potential for adherence to prescribed therapy, frailty, and functional and cognitive ability. © 2013 Ferguson et al, publisher and licensee Dove Medical Press Ltd

    Untangling the ATR-CHEK1 network for prognostication, prediction and therapeutic target validation in breast cancer

    Get PDF
    Background: ATR-Chk1 signalling network is critical for genomic stability. ATR-Chk1 may be deregulated in breast cancer and have prognostic, predictive and therapeutic significance. Patients and methods: We investigated ATR and phosphorylated CHK1Ser345 protein (pChk1) expression in 1712 breast cancers (Nottingham Tenovus series). ATR and Chk1 mRNA were evaluated in 1950 breast cancers (METABRIC cohort). Pre-clinically, biological consequences of ATR gene knockdown or ATR inhibition by small molecule inhibitor (VE-821) were investigated in MCF-7 and MDA-MB-231 breast cancer cell lines and in non-tumorigenic breast epithelial cells (MCF10A). Results: High ATR and high cytoplasmic pChk1 expression was significantly associated with higher tumour stage, higher mitotic index, pleomorphism and lymphovascular invasion. In univariate analysis, high ATR and high cytoplasmic pChk1 protein expression was associated with shorter breast cancer specific survival (BCSS). In multivariate analysis, high ATR remains an independent predictor of adverse outcome. At the mRNA level, high Chk1 remains associated with aggressive phenotypes including lymph node positivity, high grade, Her-2 overexpression, triple-negative phenotype and molecular classes associated with aggressive behaviour and shorter survival.. Pre-clinically, Chk1 phosphorylation at serine 345 following replication stress (induced by gemcitabine or hydroxyurea treatment) was impaired in ATR knockdown and in VE-821 treated breast cancer cells. Doxycycline inducible knockdown of ATR suppressed growth, which was restored when ATR was re-expressed. Similarly, VE-821 treatment resulted in a dose dependent suppression of cancer cell growth and survival (MCF7 and MDA-MB-231) but had no effect on non-tumorigenic breast epithelial cells (MCF10A). Conclusions: We provides evidence that ATR and Chk1 are promising biomarkers and rational drug target for personalized therapy in breast cancer

    Evaluation of CyberKnife ® fiducial tracking limitations to assist targeting accuracy: A phantom study with fiducial displacement

    Get PDF
    Introduction The underlying assumptions of the CyberKnife® (Accuray, Sunnyvale, CA, US) fiducial tracking system are: i) fiducial positions are accurately detected; ii) inter-fiducial geometry remains consistent (rigid); iii) inter-fiducial geometric array changes are detected and either accommodated with corrections or treatment is interrupted. However: i) soft-tissue targets are deformable & fiducial migration is possible; ii) the accuracy of the tracking system has not previously been examined with fiducial displacement; iii) treatment interruptions may occur due to inter-fiducial geometric changes, but there is little information available to assist subsequent troubleshooting. The purpose of this study was to emulate a clinical target defined with a two, three, or four-fiducial array where one fiducial is displaced to mimic a target deformation or fiducial migration scenario. The objectives: evaluate the fiducial positioning accuracy, array interpretation, & corresponding corrections of the CyberKnife system, with the aim of assisting troubleshooting following fiducial displacement. Methods A novel solid-water phantom was constructed with three fixed fiducials (F1,F2,F3) & one moveable fiducial (F4), arranged as if placed to track an imaginary clinical target. Using either two fiducials (F1,F4), different combinations of three fiducials (F1,F2,F4; F1,F3,F4; F2,F3,F4) or four fiducials (F1,F2,F3,F4), repeat experiments were conducted where F4 was displaced inferiorly at 2-mm intervals from 0-16 mm. Data were acquired at each position of F4, including rigid body errors (RBE), fiducial x, y, & z coordinate displacements, six degrees of freedom (DOF) corrections, & robot center-of-mass (COM) translation corrections. Results Maximum positioning difference (mean±SD) between the reference and live x, y, & z coordinates for the three fixed fiducials was 0.08±0.30 mm, confirming good accuracy for fixed fiducial registration. For two fiducials (F1,F4), F4 registration was accurate to 14-mm displacement and the F4 x-axis coordinate change was 2.0±0.12 mm with each 2 mm inferior displacement validating the phantom for tracking evaluation. RBE was >5 mm (system threshold) at 6-14 mm F4 displacement: however, F1 was misidentified as the RBE main contributor. Further, F1/F4 false-lock occurred at 16 mm F4 displacement with corresponding RBE 13 mm. For combinations of three fiducials, F4 registration was accurate to 10-mm displacement. RBE was >5 mm at 6-16 mm F4 displacement: however, F4 false-lock occurred at 12-16 mm with RBE 5-6 mm. For four fiducials, F4 registration was accurate to 4 mm displacement: however, F4 false-lock occurred at 6-16 mm displacement with concerning RBE <2 & <5 at 6 & 8-mm F4 displacement, respectively. False-locks were easily identified in the phantom but frequently uncorrectable. Conclusions Results indicate fiducial positioning accuracy and system output following fiducial displacement depends on the number of fiducials correlated, displacement distance, and clinical thresholds applied. Displacements ≤4 mm were accurately located, but some displacements 6-16 mm were misrepresented, either by erroneous main contributor (two-fiducial array only) or by false-locks and misleading RBE, which underestimated displacement. Operator vigilance and implementation of our practical guidelines based on the study findings may help reduce targeting error and assist troubleshooting in clinical situations
    • …
    corecore