10 research outputs found
No difference in anterior tibial translation with and without posterior cruciate ligament in less invasive total knee replacement
The relative advantages of cruciate retaining or cruciate resecting total knee replacement are still controversial. If the posterior cruciate ligament (PCL) is preserved, it should be properly balanced. In a previous study, it was demonstrated that increasing the flexion gap leads to an anterior translation of the tibia relative to the femur. Based on these results, we hypothesized that cutting the PCL increases the flexion gap and lessens anterior tibial translation
Five-year results of cervical disc prostheses in the SWISSspine registry
Background: The Swiss Federal Office of Public Health demanded a nationwide HTA-registry for cervical total disc arthroplasty (TDA), to decide about its reimbursement. The goal of the SWISSspine registry is to generate evidence about the safety and efficiency of cervical TDA. Materials and methods: Three hundred thirty-two cases treated between 3.2005 and 6.2006 who were eligible for 5years follow-ups were included in the study. Follow-up rates for 3-6months, 1, 2 and 5years were 84.6, 74.4, 50.6 and 64.8%, respectively. Outcome measures were neck and arm pain, medication, quality of life, intraoperative and postoperative complication and revision rates. In addition, segmental mobility, ossification, adjacent and distant segment degeneration were analyzed at the 5-year follow-up. Results: There was significant, clinically relevant and lasting reduction of neck (preop/postop 60/21 VAS points) and arm pain (preop/postop VAS 67/17) and a consequently decreased analgesics consumption and quality of life improvement (preop/postop 0.39/0.82 EQ-5D points) until the 5-year follow-up. The rates for intraoperative and early postoperative complications were 0.6 and 7.2%, respectively. In 0.6% an early and in 3.9% a late revision surgery was performed. At the 5-year follow-up, the average range of motion of the mobile segments (88.2%) was 10.2°. In 40.7% of the patients osteophytes at least potentially affecting range of motion were seen. Conclusions: Cervical TDA appeared as safe and efficient in long-term pain alleviation, consequent reduction of pain killer consumption and in improvement of quality of life. The improvement is stable over the 5years postoperative period. The vast majority of treated segments remained mobile after 5years, although 40.7% of patients showed osteophyte
Five-year results of lumbar disc prostheses in the SWISSspine registry
Purpose: The Swiss Federal Office of Public Health demanded a nationwide HTA registry for lumbar total disc arthroplasty (TDA), to decide about its reimbursement. The goal of the SWISS spine registry is to generate evidence about the safety and efficiency of lumbar TDA. Methods: Two hundred forty-eight cases treated between 3-2005 and 6-2006, who were eligible for the 5-year follow-up were included in the study. Follow-up rates for 3-6months, 1, 2 and 5years were 85.9, 77.0, 44.0 and 51.2%, respectively. Outcome measures were back and leg pain, medication consumption, quality of life, intraoperative and postoperative complication and revision rates. Additionally, segmental mobility, ossification, adjacent and distant segment degeneration were analysed at the 5-year follow-up. Results: There was a significant, clinically relevant and lasting reduction of back (preop/postop 73/29 VAS points) and leg pain (preop/postop VAS 55/22) and a consequently decreased analgesics consumption and quality of life improvement (preop/postop 0.30/0.76 EQ-5D score points) until 5years after surgery. The rates for intraoperative and early postoperative complications were 4.4 and 3.2%, respectively. The overall complication rate during five postoperative years was 23.4%, and the adjacent segment degeneration rate was 10.7%. In 4.4 % of patients, a revision surgery was performed. Cumulative survivorship probability for a revision/re-intervention-free 5-year postoperative course was 90.4%. At the 5-year follow-up, the average range of motion of the mobile segments (86.8%) was 9.7°. In 43.9% of patients, osteophytes at least potentially affecting the range of motion were seen. Conclusions: Lumbar TDA appeared as efficient in long-term pain alleviation, consequent reduction of pain medication consumption and improvement of quality of life. The procedure also appeared sufficiently safe, but surgeons have to be aware of a list of potential adverse events. The outcome is stable over the 5-year postoperative period. The vast majority of treated segments remained mobile after 5years, although almost half of patients showed osteophytes
Consecutive series of 226 journey bicruciate substituting total knee replacements: early complication and revision rates
BACKGROUND
The Journey bicruciate substituting (BCS) total knee replacement (TKR) is intended to improve knee kinematics by more closely approximating the surfaces of a normal knee. The purpose of this analysis was to address the safety of Journey BCS knees by studying early complication and revision rates in a consecutive case series.
METHODS
Between December 2006 and May 2011, a single surgeon implanted 226 Journey BCS total knee prostheses in 191 patients (124 women, 67 men) who were eligible for study. Mean age at surgery was 68 years (41-85 years).Outcome measures were early complications and minor and major revision rates. All complications were considered, irrespective of whether conservative treatment or revision was required.
RESULTS
The average implantation time was 3.5 years (range 1.3-5.8 years). Thirty-three complications (14.6% of 226 knees) required minor or major revision surgery in 25 patients. The remaining eight patients were treated conservatively. Sixteen minor revisions were performed in 12 patients. Thirteen major revisions were required in 13 patients, which results in a rate of 1.65 major revisions per 100 component years. The linear trend of the early complication rate by treatment year was not significant (p = .22).Multivariate logistic regression showed no significant predictors for the occurrence of a complication or for revision surgery. A tendency towards higher complication rates was observed in female patients, although it was not significant (p = .066).
CONCLUSIONS
The complication and revision rates of the Journey BCS knee implant are high in comparison with those reported for other established total knee systems. Caution is advised when using this implant, particularly for less experienced knee surgeons
In vivo compatibility of Dynesys(®) spinal implants: a case series of five retrieved periprosthetic tissue samples and corresponding implants
PURPOSE
To determine whether particulate debris is present in periprosthetic tissue from revised Dynesys(®) devices, and if present, elicits a biological tissue reaction.
METHODS
Five Dynesys(®) dynamic stabilization systems consisting of pedicle screws (Ti alloy), polycarbonate-urethane (PCU) spacers and a polyethylene-terephthalate (PET) cord were explanted for pain and screw loosening after a mean of 2.86 years (1.9-5.3 years). Optical microscopy and scanning electron microscopy were used to evaluate wear, deformation and surface damage, and attenuated total reflectance Fourier transform infrared spectroscopy to assess surface chemical composition of the spacers. Periprosthetic tissue morphology and wear debris were determined using light microscopy, and PCU and PET wear debris by polarized light microscopy.
RESULTS
All implants had surface damage on the PCU spacers consistent with scratches and plastic deformation; 3 of 5 exhibited abrasive wear zones. In addition to fraying of the outer fibers of the PET cords in five implants, one case also evidenced cord fracture. The pedicle screws were unremarkable. Patient periprosthetic tissues around the three implants with visible PCU damage contained wear debris and a corresponding macrophage infiltration. For the patient revised for cord fracture, the tissues also contained large wear particles (>10 μm) and giant cells. Tissues from the other two patients showed comparable morphologies consisting of dense fibrous tissue with no inflammation or wear debris.
CONCLUSIONS
This is the first study to evaluate wear accumulation and local tissue responses for explanted Dynesys(®) devices. Polymer wear debris and an associated foreign-body macrophage response were observed in three of five cases
Five-year results of cervical disc prostheses in the SWISSspine registry
BACKGROUND: The Swiss Federal Office of Public Health demanded a nationwide HTA-registry for cervical total disc arthroplasty (TDA), to decide about its reimbursement. The goal of the SWISSspine registry is to generate evidence about the safety and efficiency of cervical TDA. MATERIALS AND METHODS: Three hundred thirty-two cases treated between 3.2005 and 6.2006 who were eligible for 5 years follow-ups were included in the study. Follow-up rates for 3-6 months, 1, 2 and 5 years were 84.6, 74.4, 50.6 and 64.8 %, respectively. Outcome measures were neck and arm pain, medication, quality of life, intraoperative and postoperative complication and revision rates. In addition, segmental mobility, ossification, adjacent and distant segment degeneration were analyzed at the 5-year follow-up. RESULTS: There was significant, clinically relevant and lasting reduction of neck (preop/postop 60/21 VAS points) and arm pain (preop/postop VAS 67/17) and a consequently decreased analgesics consumption and quality of life improvement (preop/postop 0.39/0.82 EQ-5D points) until the 5-year follow-up. The rates for intraoperative and early postoperative complications were 0.6 and 7.2 %, respectively. In 0.6 % an early and in 3.9 % a late revision surgery was performed. At the 5-year follow-up, the average range of motion of the mobile segments (88.2 %) was 10.2°. In 40.7 % of the patients osteophytes at least potentially affecting range of motion were seen. CONCLUSIONS: Cervical TDA appeared as safe and efficient in long-term pain alleviation, consequent reduction of pain killer consumption and in improvement of quality of life. The improvement is stable over the 5 years postoperative period. The vast majority of treated segments remained mobile after 5 years, although 40.7 % of patients showed osteophytes
Five-year results of lumbar disc prostheses in the SWISSspine registry
PURPOSE
The Swiss Federal Office of Public Health demanded a nationwide HTA registry for lumbar total disc arthroplasty (TDA), to decide about its reimbursement. The goal of the SWISS spine registry is to generate evidence about the safety and efficiency of lumbar TDA.
METHODS
Two hundred forty-eight cases treated between 3-2005 and 6-2006, who were eligible for the 5-year follow-up were included in the study. Follow-up rates for 3-6 months, 1, 2 and 5 years were 85.9, 77.0, 44.0 and 51.2 %, respectively. Outcome measures were back and leg pain, medication consumption, quality of life, intraoperative and postoperative complication and revision rates. Additionally, segmental mobility, ossification, adjacent and distant segment degeneration were analysed at the 5-year follow-up.
RESULTS
There was a significant, clinically relevant and lasting reduction of back (preop/postop 73/29 VAS points) and leg pain (preop/postop VAS 55/22) and a consequently decreased analgesics consumption and quality of life improvement (preop/postop 0.30/0.76 EQ-5D score points) until 5 years after surgery. The rates for intraoperative and early postoperative complications were 4.4 and 3.2 %, respectively. The overall complication rate during five postoperative years was 23.4 %, and the adjacent segment degeneration rate was 10.7 %. In 4.4 % of patients, a revision surgery was performed. Cumulative survivorship probability for a revision/re-intervention-free 5-year postoperative course was 90.4 %. At the 5-year follow-up, the average range of motion of the mobile segments (86.8 %) was 9.7°. In 43.9 % of patients, osteophytes at least potentially affecting the range of motion were seen.
CONCLUSIONS
Lumbar TDA appeared as efficient in long-term pain alleviation, consequent reduction of pain medication consumption and improvement of quality of life. The procedure also appeared sufficiently safe, but surgeons have to be aware of a list of potential adverse events. The outcome is stable over the 5-year postoperative period. The vast majority of treated segments remained mobile after 5 years, although almost half of patients showed osteophytes
The course of radiographic loosening, pain and functional outcome around the first revision of a total hip arthroplasty
Background: The published data on pain and physical function before and after revision of total hip arthroplasty (THA) is scarce. The study reports the course and interrelationships of radiographic loosening, pain and physical function 5 year before and after a first revision THA. Methods. The study was based on the IDES-THA database. All patients with their first THA revision for aseptic loosening and a documented index surgery on the same side and at least one pre-revision and one post-revision follow-up were selected. Only patients with an intact contralateral hip joint (Charnley class-A) were included. Follow-ups within ±5.5 years around the revision time point were analyzed. Annual prevalences of radiographic component loosening and the non-desired outcomes (moderate/severe/intolerable pain, walking <30 minutes, hip flexion range <90°) were calculated. Results: Signs of radiographic component loosening started to increase about 4 years before revision surgery. Two years later, a sharp increase of painful hips from 15% to 80% in the revision year was observed. In the year after revision surgery, this rate dropped back to below 10%. Walking capacity started to noticeably deteriorate 3 years before revision and in the revision year about 65% of patients could not walk longer than 30 minutes. As opposed to pain, walking capacity did not recover to pre-revision levels and the best outcome was only reached two years post-revision. Hip flexion range had the slowest and least extent of deterioration (˜45% flexed <70° in the revision year) but with the best outcomes at only three years after revision surgery it took the longest to recover. Conclusion: Prevalence of radiological loosening signs and/or pain intensity follow an almost parallel course around the first revision of a THA for aseptic component loosening. This process begins about 4 years (radiographic loosening) before the actual revision surgery and intensifies about 2 years later (pain). It also involves walking capacity and hip range of motion. While pain levels go back to levels similar to those after primary surgery, range of motion and even more walking capacity remain moderately compromised. © 2013 Aghayev et al.; licensee BioMed Central Ltd