14 research outputs found

    First Study of Combined Blazar Light Curves with FACT and HAWC

    Full text link
    For studying variable sources like blazars, it is crucial to achieve unbiased monitoring, either with dedicated telescopes in pointing mode or survey instruments. At TeV energies, the High Altitude Water Cherenkov (HAWC) observatory monitors approximately two thirds of the sky every day. It uses the water Cherenkov technique, which provides an excellent duty cycle independent of weather and season. The First G-APD Cherenkov Telescope (FACT) monitors a small sample of sources with better sensitivity, using the imaging air Cherenkov technique. Thanks to its camera with silicon-based photosensors, FACT features an excellent detector performance and stability and extends its observations to times with strong moonlight, increasing the duty cycle compared to other imaging air Cherenkov telescopes. As FACT and HAWC have overlapping energy ranges, a joint study can exploit the longer daily coverage given that the observatories' locations are offset by 5.3 hours. Furthermore, the better sensitivity of FACT adds a finer resolution of features on hour-long time scales, while the continuous duty cycle of HAWC ensures evenly sampled long-term coverage. Thus, the two instruments complement each other to provide a more complete picture of blazar variability. In this presentation, the first joint study of light curves from the two instruments will be shown, correlating long-term measurements with daily sampling between air and water Cherenkov telescopes. The presented results focus on the study of the variability of the bright blazars Mrk 421 and Mrk 501 during the last two years featuring various flaring activities.Comment: 6 pages, 2 figures. Contribution to the 6th International Symposium on High Energy Gamma-Ray Astronomy (Gamma2016), Heidelberg, Germany. To be published in the AIP Conference Proceeding

    Contribución al conocimiento de Porosagrotis gypaetina (Guen.) (Lep.:Noctuidae)

    Get PDF
    p.15-22Este trabajo tiene por finalidad brindar una descripcion detallada de los diferentes estados de desarrollo, asi como de los estadios larvales, de Porosagrotis gypaetina (Guen.) y estimar sus principales parametros biologicos. Se trata de una oruga conocida vulgarmente como gusano pardo que frecuenta cultivos de alfalfa, trebol bianco, maiz y girasol y determinadas malezas. Los caracteres considerados para su identificacion fueron, en el huevo: numero y distribucion de costas; en la larva: pigmentacion, distribucion de manchas y cerdas corporales; en la pupa: tamaño, forma y color y caracteristicas del cremaster; y en el adulto: ubicacion y coloracion de maculas y nervaduras alares. La emergencia de imagos alcanzo su maximo en abril y mayo. El periodo embrionario se completo en 22 a 26 dias. Aproximadamente la mitad de las larvas cumplieron su ciclo en 6 estadios y las restantes en 7; la duracion total del periodo larval fue de 134 a 141 dias, sin considerar la forma prepupal e independientemente del numero de estadios. Las orugas permanecieron como prepupas durante la temporada estival (aproximadamente 161 dias). El estado pupal duro 40 a 57 dias. Las observaciones realizadas permiten expresar que, inediante los caracteres descriptos, es factible reconocer la especie a traves no solo de los adultos, sino de sus estados inmaduros. Posee una sola generacion anual; transcurre el inviemo como larva; el daño tipico de corte lo produce a partir del cuarto estadio larval

    The individual-cell-based cryo-chip for the cryopreservation, manipulation and observation of spatially identifiable cells. I: Methodology

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Cryopreservation is the only widely applicable method of storing vital cells for nearly unlimited periods of time. Successful cryopreservation is essential for reproductive medicine, stem cell research, cord blood storage and related biomedical areas. The methods currently used to retrieve a specific cell or a group of individual cells with specific biological properties after cryopreservation are quite complicated and inefficient.</p> <p>Results</p> <p>The present study suggests a new approach in cryopreservation, utilizing the Individual Cell-based Cryo-Chip (i3C). The i3C is made of materials having appropriate durability for cryopreservation conditions. The core of this approach is an array of picowells, each picowell designed to maintain an individual cell during the severe conditions of the freezing - thawing cycle and accompanying treatments. More than 97% of cells were found to retain their position in the picowells throughout the entire freezing - thawing cycle and medium exchange. Thus the comparison between pre-freezing and post-thawing data can be achieved at an individual cell resolution. The intactness of cells undergoing slow freezing and thawing, while residing in the i3C, was found to be similar to that obtained with micro-vials. However, in a fast freezing protocol, the i3C was found to be far superior.</p> <p>Conclusions</p> <p>The results of the present study offer new opportunities for cryopreservation. Using the present methodology, the cryopreservation of individual identifiable cells, and their observation and retrieval, at an individual cell resolution become possible for the first time. This approach facilitates the correlation between cell characteristics before and after the freezing - thawing cycle. Thus, it is expected to significantly enhance current cryopreservation procedures for successful regenerative and reproductive medicine.</p

    Long-term monitoring of bright blazars in the multi-GeV to TeV range with FACT

    Get PDF
    Blazars like Markarian 421 or Markarian 501 are active galactic nuclei (AGN), with their jets orientated towards the observer. They are among the brightest objects in the very high energy (VHE) gamma ray regime (>100 GeV). Their emitted gamma-ray fluxes are extremely variable, with changing activity levels on timescales between minutes, months, and even years. Several questions are part of the current research, such as the question of the emission regions or the engine of the AGN and the particle acceleration. A dedicated longterm monitoring program is necessary to investigate the properties of blazars in detail. A densely sampled and unbiased light curve allows for observation of both high and low states of the sources, and the combination with multi-wavelength observation could contribute to the answer of several questions mentioned above. FACT (First G-APD Cherenkov Telescope) is the first operational telescope using silicon photomultiplier (SiPM, also known as Geigermode—Avalanche Photo Diode, G-APD) as photon detectors. SiPM have a very homogenous and stable longterm performance, and allow operation even during full moon without any filter, leading to a maximal duty cycle for an Imaging Air Cherenkov Telescope (IACT). Hence, FACT is an ideal device for such a longterm monitoring of bright blazars. A small set of sources (e.g., Markarian 421, Markarian 501, 1ES 1959+650, and 1ES 2344+51.4) is currently being monitored. In this contribution, the FACT telescope and the concept of longterm monitoring of bright blazars will be introduced. The results of the monitoring program will be shown, and the advantages of densely sampled and unbiased light curves will be discussed

    Multiwavelength study of quiescent states of MRK 421 with unprecedented hard x-ray coverage provided by<i> NuSTAR</i> in 2013

    Get PDF

    FACT - Highlights from more than Five Years of Unbiased Monitoring at TeV Energies

    No full text
    The First G-APD Cherenkov Telescope (FACT) is monitoring blazars at TeV energies. Thanks to the observing strategy, the automatic operation and the usage of solid state photosensors (SiPM, aka G-APDs), the duty cycle of the instrument has been maximized and the observational gaps minimized. This provides a unprecedented, unbiased data sample of almost 9000~hours of data of which 2375 hours were taken in 2016. An automatic quick look analysis provides results with low latency on a public website. More than 40 alerts have been sent in the last three years based on this. To study the origin of the very high energy emission from blazars simultaneous multi-wavelength and multi-messenger observations are crucial to draw conclusions on the underlying emission mechanisms, e.g. to distinguish between leptonic and hadronic models. FACT not only participates in multi-wavelength studies, correlation studies with other instruments and multi-messenger studies, but also collects time-resolved spectral energy distributions using a target-of-opportunity program with X-ray satellites. At TeV energies, FACT provides an unprecedented, unbiased data sample. Using up to 1850 hours per source, the duty cycle of the sources and the characteristics of flares at TeV energies are studied. In the presentation, the highlights from more than five years of monitoring will be summarized including several flaring activities of Mrk 421, Mrk 501 and 1ES 1959+650.ISSN:1824-803

    Bokeh mirror alignment for Cherenkov telescopes

    No full text
    Imaging Atmospheric Cherenkov Telescopes (IACTs) need imaging optics with large apertures and high image intensities to map the faint Cherenkov light emitted from cosmic ray air showers onto their image sensors. Segmented reflectors fulfill these needs, and composed from mass production mirror facets they are inexpensive and lightweight. However, as the overall image is a superposition of the individual facet images, alignment remains a challenge. Here we present a simple, yet extendable method, to align a segmented reflector using its Bokeh. Bokeh alig nment does not need a star or good weather nights but can be done even during daytime. Bokeh alignment optimizes the facet orientations by comparing the segmented reflectors Bokeh to a predefined template. The optimal Bokeh template is highly constricted by the reflector's aperture and is easy accessible. The Bokeh is observed using the out of focus image of a near by point like light source in a distance of about 10 focal lengths. We introduce Bokeh alignment on segmented reflectors and demonstrate it on the First Geiger-mode Avalanche Cherenkov Telescope (FACT) on La Palma, Spain.SCOPUS: ar.jinfo:eu-repo/semantics/publishe

    FACT – Performance of the First Cherenkov Telescope Observing with SiPMs

    No full text
    The First G-APD Cherenkov Telescope (FACT) is pioneering the usage of silicon photo mul- tipliers (SiPMs also known as G-APDs) for the imaging atmospheric Cherenkov technique. It is located at the Observatorio Roque de los Muchachos on the Canary island of La Palma. Since first light in October 2011, it is monitoring bright TeV blazars in the northern sky. By now, FACT is the only imaging atmospheric Cherenkov telescope operating with S I PMs on a nightly basis. Over the course of the last five years, FACT has been demonstrating their reliability and excel- lent performance. Moreover, their robustness allowed for an increase of the duty cycle including nights with strong moon light without the need for UV-filters. In this contribution, we will present the performance of the first Cherenkov telescope using solid state photo sensors, which was determined in analysis of data from Crab Nebula, the so called standard candle in gamma-ray astronomy. The presented analysis chain utilizes modern data mining methods and unfolding techniques to obtain the energy spectrum of this source. The characteristical results of such an analysis will be reported providing, e. g., the angular and energy resolution of FACT, as well as, the energy spectrum of the Crab Nebula. Furthermore, these results are discussed in the context of the performance of coexisting Cherenkov telescopes
    corecore