1,770 research outputs found

    Non-thermal X-ray Emission: An Alternative to Cluster Cooling Flows?

    Get PDF
    We report the results of experiments aimed at reducing the major problem with cooling flow models of rich cluster X-ray sources: the fact that most of the cooled gas or its products have not been found. Here we show that much of the X-ray emission usually attributed to cooling flows can, in fact, be modeled by a power-law component which is indicative of a source(s) other than thermal bremsstrahlung from the intracluster medium. We find that adequate simultaneous fits to ROSAT PSPCB and ASCA GIS/SIS spectra of the central regions of ten clusters are obtained for two-component models that include a thermal plasma component that is attributable to hot intracluster gas and a power-law component that is likely generated by compact sources and/or extended non-thermal emission. For five of the clusters that purportedly have massive cooling flows, the best-fit models have power-law components that contribute ∼\sim 30 % of the total flux (0.14 - 10.0 keV) within the central 3 arcminutes. Because cooling flow mass deposition rates are inferred from X-ray fluxes, our finding opens the possibility of significantly reducing cooling rates.Comment: 11 pages, 3 figures, emulateapj style. Accepted for publication in Ap

    Latitudinal and cross-shelf patterns of size, age, growth, and mortality of a tropical damselfish Acanthochromis polyacanthus on the Great Barrier Reef

    Get PDF
    Patterns of age and growth of a sedentary damsel fish Acanthochromis polyacanthus were tested over a latitudinal range of approximately 10 degrees (1200 km) on the Great Barrier Reef (GBR), Australia. Within latitudes, these patterns were also compared on reefs in distance strata (inner, mid, and outer) across a continental shelf that ranged in width from 52 to 128 km. Although variation in length-max (SLMAX), growth, age-max (AMAX), and the von Bertalanffy metrics of Linf and K were found within and among latitudes, the greatest variation in some demographic characteristics was found among distance strata across the shelf regardless of latitude. Fish were always relatively smaller at inner shelf reefs and grew more slowly when compared to mid and outer shelf reefs; this was true regardless of the color morph of fish. The oldest fish collected was 11 years old, and there was no consistent variation in age-max among distances from shore. On outer reefs, there was a negative linear relationship with age-max and latitude. This "tropical gradient" of age only explained 34% of the variation; furthermore, this was not found when only the oldest group of fish was considered (top 10%). Fish only reached an age-max of six years on the southernmost reefs. There was a trend for a smaller Linf with latitude but it was not significant and Linf did not vary predictably with water temperature. The sampling ofmarine protected areas (MPAs) and fished zones did not confound the resultant patterns in that fish were not consistently larger or older inMPAs or fished zones. Instantaneous mortality rates were 0.245-0.685; they were highest at inner reefs and also showed no consistentMPA-related patterns. Our study suggested that the mid and outer shelf waters of the GBR appeared best suited for growth of A. polyacanthus. In conclusion, the position on continental shelves dominated other geographical patterns and needs to be considered in spatial models of growth. We suggest that local environmental conditions such as turbidity and the quality and quantity of plankton likely have a strong influence on distance across the shelf-based demographic patterns of planktivores

    Approximate Bayesian computation scheme for parameter inference and model selection in dynamical systems

    Full text link
    Approximate Bayesian computation methods can be used to evaluate posterior distributions without having to calculate likelihoods. In this paper we discuss and apply an approximate Bayesian computation (ABC) method based on sequential Monte Carlo (SMC) to estimate parameters of dynamical models. We show that ABC SMC gives information about the inferability of parameters and model sensitivity to changes in parameters, and tends to perform better than other ABC approaches. The algorithm is applied to several well known biological systems, for which parameters and their credible intervals are inferred. Moreover, we develop ABC SMC as a tool for model selection; given a range of different mathematical descriptions, ABC SMC is able to choose the best model using the standard Bayesian model selection apparatus.Comment: 26 pages, 9 figure

    A case of severe adolescent obsessive-compulsive disorder treated with inpatient hospitalization, risperidone and sertraline

    Get PDF
    Background: The initial treatment of obsessive-compulsive disorder (OCD) has generally been limited to serotonergic agents, cognitive-behavioral therapy (CBT), or a combination of the two. These findings were supported by the POTS study for OCD in children and adolescents. However, treatment with serotonergic agents or CBT can take several weeks before benefit is seen; severe cases of OCD may require more immediate treatment. Case report: The authors present a case of severe OCD in an adolescent that required immediate treatment due to her critical medical condition. The patient's symptoms included not eating or taking medications or fluids by mouth due to fears of contamination. A medical hospitalization was previously required due to dehydration. As treatment with an SSRI would not have quick enough onset and the patient was initially resistant to participating in CBT, the patient was psychiatrically hospitalized and first started on liquid risperidone. After several doses of risperidone, the patient was able to participate in CBT and start sertraline. Discussion: The authors discuss the differential diagnosis of such a patient, including the continuum of OCD symptoms and psychotic symptoms. The authors discuss the different treatment options, including the utilization of inpatient psychiatric hospitalization. The authors discuss the potential risks and benefits of using atypical antipsychotics in lieu of benzodiazepines for the initial treatment of severe adolescent OCD. The authors also discuss other current treatment recommendations and rationale for the treatment that was pursued. Conclusions: This patient received benefit of her symptoms relatively quickly with psychiatric hospitalization and an atypical antipsychotic. The diagnosis of a psychotic disorder should be considered. These treatment options must be weighed against the risks of atypical antipsychotics, including extrapyramidal symptoms, weight gain, and metabolic syndrome; benzodiazepines also have their risks and benefits. Additionally, the cost of time and finances of inpatient hospitalization must be considered. More research is needed regarding the short- and long-term efficacy and safety of antipsychotics in the treatment of OCD in the child and adolescent population

    Efficiency of spinal anesthesia versus general anesthesia for lumbar spinal surgery: a retrospective analysis of 544 patients.

    Get PDF
    BACKGROUND: Previous studies have shown varying results in selected outcomes when directly comparing spinal anesthesia to general in lumbar surgery. Some studies have shown reduced surgical time, postoperative pain, time in the postanesthesia care unit (PACU), incidence of urinary retention, postoperative nausea, and more favorable cost-effectiveness with spinal anesthesia. Despite these results, the current literature has also shown contradictory results in between-group comparisons. MATERIALS AND METHODS: A retrospective analysis was performed by querying the electronic medical record database for surgeries performed by a single surgeon between 2007 and 2011 using procedural codes 63030 for diskectomy and 63047 for laminectomy: 544 lumbar laminectomy and diskectomy surgeries were identified, with 183 undergoing general anesthesia and 361 undergoing spinal anesthesia (SA). Linear and multivariate regression analyses were performed to identify differences in blood loss, operative time, time from entering the operating room (OR) until incision, time from bandage placement to exiting the OR, total anesthesia time, PACU time, and total hospital stay. Secondary outcomes of interest included incidence of postoperative spinal hematoma and death, incidence of paraparesis, plegia, post-dural puncture headache, and paresthesia, among the SA patients. RESULTS: SA was associated with significantly lower operative time, blood loss, total anesthesia time, time from entering the OR until incision, time from bandage placement until exiting the OR, and total duration of hospital stay, but a longer stay in the PACU. The SA group experienced one spinal hematoma, which was evacuated without any long-term neurological deficits, and neither group experienced a death. The SA group had no episodes of paraparesis or plegia, post-dural puncture headaches, or episodes of persistent postoperative paresthesia or weakness. CONCLUSION: SA is effective for use in patients undergoing elective lumbar laminectomy and/or diskectomy spinal surgery, and was shown to be the more expedient anesthetic choice in the perioperative setting

    Improved Production and Separation Technologies for Non-standard PET Radionuclides

    Get PDF
    Brief summary of activity issues, concerns, successes: Project 1 is completed. We have optimized plating parameters with the new target bodies and slanted target plating system. The target station has been mounted on the end of the beamline, service lines have been nstalled to allow for helium and water cooling. We have routinely produced copper-64 using the new slanted target system in conjunction with our automated system. In project 2, we successfully fabricated and tested microfluidic extraction devices made out of two organic solvent-resistant polymers, thiolene and SIFEL. Initially, we developed analytical and computational models to describe the extraction process, and used the model to design the microfluidic devices. Then we optimized the microfabrication procedures to manufacture microreactors, followed by optimization of the operational parameters to obtain a stable aqueous-organic interface, which is critical for efficient extraction. When we tested the thiolene devices for extraction of copper-64, we observed very low extraction efficiencies (less than 5%) due to adhesion of copper to thiolene. However, we observed very high extraction efficiencies with SIFEL devices (greater than 95%), which are due to the high interfacial area for extraction and shorter diffusion lengths
    • …
    corecore