1,042 research outputs found

    Open Access Of Research: Which Role In The Processes Of Evaluation? Experience By The Agenzia Nazionale Di Valutazione Del Sistema Universitario E Della Ricerca (Anvur)

    Get PDF
    This article focuses on Open Access and Research Evaluation, and the experience by the Italian National Agency for the Evaluation of Universities and Research Institutes (ANVUR). It is an updated version of the work presented at the Workshop "Open Science: new models of scientific communication and research evaluation", organized by Virginia Valzano at the University of Salento, on January 30, 2019

    The size criteria in minimally invasive video-assisted thyroidectomy

    Get PDF
    BACKGROUND: Thyroid size is a very important criteria of MIVAT exclusion because the working space provided by the technique is limited. The aim of this work has been to verify the suitability of MIVAT and its applicability in clinical practice, not only in patients with a thyroid volume up to 25 ml but also in patients with a thyroid volume included from 25 to 50 ml. METHODS: From January 2003 to February 2006, 33 patients have been selected for MIVAT. A completely gasless procedure was carried out through a central 20 to 35 mm skin incision performed "high" between the cricoid and jugular notch. RESULTS: The patients were separated in 2 groups. The first group (less than 25 ml) included 23 patients, the second group (from 25 to 50 ml) included 10 patients. The skin incision performed was from 20 to 25 mm (mean 23.61 mm ± 1.83) long in the first group and from 25 to 35 mm (mean 27.8 mm ± 2.20) long in the second one; this difference is significant (t test p < 0.001). CONCLUSION: Our study suggest that the MIVAT using for thyroids bigger than 25 ml and up to 50 ml in volume is feasible and safe. This way allows more patients, excluded before, to take the advantages of minimally invasive approach

    The minimally invasive open video-assisted approach in surgical thyroid diseases

    Get PDF
    BACKGROUND: The targets of minimally invasive surgery (MIVA) could be summarised by: achievement of the same results as those obtained with traditional surgery, less trauma, better post-operative course, early discharge from hospital and improved cosmetic results. The minimally invasive techniques in thyroid surgery can be described as either endoscopic "pure" approach (completely closed approach with or without CO(2 )insufflation), or "open approach" with central neck mini-incision or "open video-assisted approach". Traditionally, open thyroidectomy requires a 6 to 8 cm, or bigger, transverse wound on the lower neck. The minimally invasive approach wound is much shorter (1.5 cm for small nodules, up to 2–3 cm for the largest ones, in respect of the exclusion criteria) upon the suprasternal notch. Patients also experience much less pain after MIVA surgery than after conventional thyroidectomy. This is due to less dissection and destruction of tissues. Pathologies treated are mainly nodular goiter; the only kind of thyroid cancer which may be approached with endoscopic surgery is a small differentiated carcinoma without lymph node involvement. The patients were considered eligible for MIVA hemithyroidectomy and thyroidectomy on the basis of some criteria, such as gland volume and the kind of disease. In our experience we have chosen the minimally invasive open video-assisted approach of Miccoli et al. (2002). The aim of this work was to verify the suitability of the technique and the applicability in clinical practice. METHODS: A completely gasless procedure was carried out through a 15–30 mm central incision about 20 mm above the sternal notch. Dissection was mainly performed under endoscopic vision using conventional endoscopic instruments. The video aided group included 11 patients. All patients were women with a average age of 54. RESULTS: We performed thyroidectomy in 8 cases and hemithyroidectomy in 3 cases. The operative average time has been 170 minutes. CONCLUSION: Nowadays this minimally invasive surgery, in selected patients, clearly demonstrates excellent results regarding patient cure rate and comfort, with shorter hospital stay, reduced postoperative pain and most attractive cosmetic results

    Laser microgrooved vs. machined healing abutment disconnection/reconnection: a comparative clinical, radiographical and biochemical study with split-mouth design

    Get PDF
    Background: Repeated removal and replacement of healing abutments result in frequent injuries to the soft tissues.Purpose: The purpose of this study was to evaluate the effect of disconnection/reconnection of laser microgrooved vs. machined healing and prosthetic abutments on clinical periodontal parameters, marginal bone levels, and proinflammatory cytokine levels around dental implants.Material and methods: Twenty-four patients each received 2 implants with one-stage protocol in a split-mouth design on the same jaw. In each patient, one healing and prosthetic abutments with a laser microgrooved surface (LMS group) and one healing and prosthetic abutments with machined surface (MS group) were used. Four months following implant placement (T0), the healing abutments were disconnnected and reconnected three times to carry out the impression procedures and metal framework try-in. Four weeks later (T1), definitive prosthetic abutments were installated with screw-retained crowns. Modified plaque index (mPI), modified gingival index (mGI) bleeding on probing (BOP), and probing depth (PD) were recorded at T0 and T1. At the same time points, samples for immunological analyses were taken from the sulcus around each implant. Peri-implant crevicular fluid (PICF) samples were analyzed for interleukin-1beta (IL-1 beta), interleukin-6 (IL-6), and tumor necrosis factor (TNF)-alpha levels using the ELISA kit.Results: At T0 and T1, mPI and mGI showed no statistical difference between the two groups, while higher PD and BoP values were noted for the MS group (P &lt; 0.05). The mean PICF volume and mean concentrations of IL-1 beta, IL-6, and (TNF)-alpha in the LMS group were statistically less than those in the MS group (P &lt; 0.05). In addition, comparison of IL-6 and IL-1 beta mean concentrations at T0 and T1 in the MS group showed a statistically significant increase (p &lt; 0.05) over time, which was not noted for the LMS.Conclusion: Disconnection/reconnection of healing and prosthetic abutments with a laser-microgrooved surface resulted in less inflammatory molecular response compared with conventional machined ones

    ATLAS RPC Cosmic Ray Teststand at INFN Lecce

    Full text link
    We describe the design and functionality of the cosmic ray teststand built at INFN Lecce for ATLAS RPC quality control assurance.Comment: XXIV Physics in Collisions Conference (PIC04), Boston, USA, June 2004, 3 pages, LaTex, 2 eps figures. MONP0

    Changes of radiographic trabecular bone density and peri-implant marginal bone vertical dimensions around non-submerged dental implants with a laser-microtextured collar after 5 years of functional loading

    Get PDF
    Objectives: The progressive peri-implant bone remodeling caused by dynamic cycles of microdamage may change peri-implant bone characteristics and volume after the functional loading. This prospective study was designed to evaluate the radiographic trabecular bone density and peri-implant vertical dimensional changes around the non submerged dental implant with a laser-microtextured collar (NSLI)s after 5 years of functional loading. Methods: Digital periapical radiographs of 58 NSLIs supported fixed single crowns and fixed partial dentures in 26 patients (14 men, mean age of 52 ± 3.8 years) were used for comparative evaluation between the implant placement [Baseline (BSL)], the definitive Crowns Delivery (CD) and the 5 years post-functional loading examination (T5). Regions of interest (ROI) were taken into consideration for the measurement of mean gray levels, standard deviation, and variation coefficient. The texture parameters, such as contrast, correlation, angular second moment and entropy, were investigated by using the software ImageJ (v.1.50i), by means of the Gray-level Co-occurrence Matrix (GLCM) Texture Tool plugin. Vertical Periimplant Marginal Bone Level (VPMBL) was assessed at the mesial and the distal sides of each implant by subtracting the measure at BSL from the measure at T5 by means of dedicate software (VixWin Platinum Imaging Software). Mixed regression models were adopted to analyze data. The possible effects of some variables, such as the use of provisional denture, location, crown/implant ratio, type of prosthetic design (single or splinted), on radiographic dimensional vertical changes, gray levels and texture analysis variables were also evaluated. Results: From BSL to T5, mesial and distal VPMBL showed a statistically significant gain of 0.9 ±0.5, and 0.10 mm ±0.6, respectively (P&lt;0.05). From CD to T5, mean gray levels increased from 94.4±26.8) to 111.8±27.1 (P&lt;0.05), while the coefficient of variation decreased from 0.08±0,03 to 0.05±0.04) (P&lt;0.05). Variables showed no statistically significant correlation with texture parameters (P &gt; 0.05). Conclusion: NSLIs showed an increase in radiographic vertical peri-implant marginal bone levels and bone density up to 5 years of loading
    • …
    corecore