    Causes and predictors of early mortality in patients treated with left ventricular assist device implantation in the European Registry of Mechanical Circulatory Support (EUROMACS)

    Get PDF
    Purpose: The aim of the study was to analyze early mortality after continuous-flow left ventricular assist device (LVAD) implantation which remains high. Methods: We analyzed consecutive (n = 2689) patients from the European Registry for Patients with Mechanical Circulatory Support (EUROMACS) undergoing continuous-flow LVAD implantation. The primary outcome was early (< 90 days) mortality. Secondary outcomes were differential causes of early post-operative death following LVAD implantation. Results: Univariable and multivariable analysis as well as regression analysis were used to examine determinants and differential causes of early (< 90 days) mortality after LVAD implantation. During the first 90 days, 2160 (80%) patients were alive with ongoing LVAD support, 40(2%) patients underwent heart transplantation, and 487(18%) deceased. The main causes of early death were MOF (36%), sepsis (28%), cardiopulmonary failure (CPF; 10%), CVA (9%), and right-sided heart failure (RHF, 8%). Furthermore, MOF and sepsis are 70% of causes of death in the first week. Independent clinical predictors of early death were age, female sex, INTERMACS profile 1 to 3, and ECMO. Laboratory predictors included elevated serum creatinine, total bilirubin, lactate, and low hemoglobin. Furthermore, hemodynamic predictors included elevated RA-to-PCWP ratio, pulmonary vascular resistance, and low systemic vascular resistance. Longer total implantation time was also independent predictor of early mortality. A simple model of 12 variables predicts early mortality following LVAD implantation with a good discriminative power with area under the curve of 0.75. Conclusions: In the EUROMACS registry, approximately one out of five patients die within 90 days after LVAD implantation. Early mortality is primarily dominated by multiorgan failure followed by sepsis. A simple model identifies important parameters which are associated with early mortality following LVAD implantation

    The European Registry for Patients with Mechanical Circulatory Support (EUROMACS)

    Get PDF
    OBJECTIVES: A second paediatric report has been generated from the European Registry for Patients with Mechanical Circulatory Support (EUROMACS). The purpose of EUROMACS, which is operated by the European Association for Cardio-Thoracic Surgery, is to gather data related to durable mechanical circulatory support for scientific purposes and to publish reports with respect to the course of mechanical circulatory support therapy. Since the first report issued, efforts to increase compliance and participation have been extended. Additionally, the data provided the opportunity to analyse patients of younger age and lower weight. METHODS: Participating hospitals contributed pre-, peri- and long-term postoperative data on mechanical circulatory support implants to the registry. Data for all implants in paediatric patients (≤19 years of age) performed from 1 January 2000 to 1 July 2019 were analysed. This report includes updates of patient characteristics, implant frequency, outcome (including mortality rates, transplants and recovery rates) as well as adverse events including neurological dysfunction, device malfunction, major infection and bleeding. RESULTS: Twenty-nine hospitals contributed 398 registered implants in 353 patients (150 female, 203 male) to the registry. The most frequent aetiology of heart failure was any form of cardiomyopathy (61%), followed by congenital heart disease and myocarditis (16.4% and 16.1%, respectively). Competing outcomes analysis revealed that a total of 80% survived to transplant or recovery or are ongoing; at the 2-year follow-up examination, 20% died while on support. At 12 months, 46.7% received transplants, 8.7% were weaned from their device and 18.5% died. The 3-month adverse events rate was 1.69 per patient-year for device malfunction including pump exchange, 0.48 for major bleeding, 0.64 for major infection and 0.78 for neurological events. CONCLUSIONS: The overall survival rate was 81.5% at 12 months following ventricular assist device implant. The comparison of survival rates of the early and later eras shows no significant difference. A focus on specific subgroups showed that survival was less in patients of younger age (<1 year of age) (P = 0.01) and lower weight (<20 kg) (P = 0.015). Transplant rates at 6 months contin

    Outcomes of patients after successful left ventricular assist device explantation: a EUROMACS study

    Get PDF
    Aims: Sufficient myocardial recovery with the subsequent explantation of a left ventricular assist device (LVAD) occurs in approximately 1–2% of the cases. However, follow-up data about this condition are scarcely available in the literature. This study aimed to report the long-term outcomes and clinical management following LVAD explantation. Methods and results: An analysis of the European Registry for Patients with Mechanical Circulatory Support was performed to identify all adult patients with myocardial recovery and successful explantation. Pre-implant characteristics were retrieved and compared with the non-recovery patients. The follow-up data after explantation were collected via a questionnaire. A Kaplan–Meier analysis for freedom of the composite endpoint of death, heart transplantation, LVAD reimplantion, or heart failure (HF) relapse was conducted. A total of 45 (1.4%) cases with myocardial recovery resulting in successful LVAD explantation were identified. Compared with those who did not experience myocardial recovery, the explanted patients were younger (44 vs. 56 years, P < 0.001), had a shorter duration of cardiac disease (P < 0.001), and were less likely to have ischaemic cardiomyopathy (9% vs. 41.8%, P < 0.001). Follow-up after explantation could be acquired in 28 (62%) cases. The median age at LVAD implantation was 43 years (inter-quartile range: 29–52),

    Low-flow support of the chronic pressure-overloaded right ventricle induces reversed remodeling

    No full text
    Mechanical right ventricular (RV) support in pulmonary arterial hypertension patients has been feared to cause pulmonary hemorrhage and to be detrimental for the after-load-sensitive RV. Continuous low-flow pumps offer promise but remain insufficiently tested.status: publishe

    The outcome of patients with peripartum cardiomyopathy and consecutive implantation of a left ventricular assist device

    No full text
    Objectives Peripartum cardiomyopathy (PPCM) is a form of systolic heart failure occurring toward the end of pregnancy or in the period after delivery. Lack of myocardial recovery or therapy-refractory cardiogenic shock are rare complications and left ventricular assist device (LVAD) systems might be used as a life-saving option. The aim of this study was to investigate outcomes of PPCM patients supported with LVAD, registered in the European Registry for Patients with Mechanical Circulatory Support (EUROMACS). Methods All patients registered in EUROMACS with a primary diagnosis of PPCM were included in this study. Demographic, preoperative, intraoperative, postoperative, and follow-up data were collected and patients analysed concerning their outcome after initiation of LVAD therapy. Results Between May 2011 and September 2018, 16 patients with PPCM and consecutive LVAD implantation were enrolled into EUROMACS. The median age of the patient population was 31 (26;41) years with a mean left ventricular ejection fraction (LV-EF) of 15% +/- 6%. In-hospital mortality after LVAD implantation was 6% (n = 1). One-year mortality accounted for 13% (n = 2). Six patients (40%) were transplanted with a median support time of 769 (193;1529) days. Weaning of LVAD support due to ventricular recovery was feasible in 3 (20%) patients. Conclusion In patients with severe PPCM, LVAD therapy is associated with considerably low in-hospital mortality, potentially allowing bridging to heart transplantation, or left ventricular recovery. Therefore, durable mechanical support should be considered as a treatment option in this, by nature, young and often otherwise healthy patient population

    Myofibroblast Phenotype and Reversibility of Fibrosis in Patients With End-Stage Heart Failure

    No full text
    BACKGROUND: Interstitial fibrosis is an important component of diastolic, and systolic, dysfunction in heart failure (HF) and depends on activation and differentiation of fibroblasts into myofibroblasts (MyoFb). Recent clinical evidence suggests that in late-stage HF, fibrosis is not reversible. OBJECTIVES: The study aims to examine the degree of differentiation of cardiac MyoFb in end-stage HF and the potential for their phenotypic reversibility. METHODS: Fibroblasts were isolated from the left ventricle of the explanted hearts of transplant recipients (ischemic and dilated cardiomyopathy), and from nonused donor hearts. Fibroblasts were maintained in culture without passaging for 4 or 8 days (treatment studies). Phenotyping included functional testing, immunostaining, and expression studies for markers of differentiation. These data were complemented with immunohistology and expression studies in tissue samples. RESULTS: Interstitial fibrosis with cross-linked collagen is prominent in HF hearts, with presence of activated MyoFbs. Tissue levels of transforming growth factor (TGF)-β1, lysyl oxidase, periostin, and osteopontin are elevated. Fibroblastic cells isolated from HF hearts are predominantly MyoFb, proliferative or nonproliferative, with mature α-smooth muscle actin stress fibers. HF MyoFb express high levels of profibrotic cytokines and the TGF-β1 pathway is activated. Inhibition of TGF-β1 receptor kinase in HF MyoFb promotes dedifferentiation of MyoFb with loss of α-smooth muscle actin and depolymerization of stress fibers, and reduces the expression of profibrotic genes and cytokines levels to non-HF levels. CONCLUSION: MyoFb in end-stage HF have a variable degree of differentiation and retain the capacity to return to a less activated state, validating the potential for developing antifibrotic therapy targeting MyoFb.status: publishe