38 research outputs found

    On the characteristics and detectability of intracranial microembolic signals

    Get PDF

    Feasibility and reliability of on-line automated microemboli detection after carotid endarterectomy. A transcranial Doppler study

    Get PDF
    AbstractObjectives: recently, a new algorithm for transcranial Doppler (TCD) ultrasound detection of microembolic signals (MES) was developed. In the present study, we investigated its on-line performance in TCD monitoring after carotid endarterectomy (CEA) and assessed off-line its accuracy in detecting MES. Materials and Methods: first, the feasibility of MES detection in TCD monitoring after CEA in a routine clinical setting was evaluated in 50 patients. Second, to test the reliability of the software a 2-h digital audio study tape was made and analysed by the algorithm and five human experts. The “gold standard” was defined as the agreement between human experts: a MES was considered to be present if at least three human observers agreed. Results: TCD monitoring for emboli detection after CEA was well tolerated by the patients and could be performed reliably. In the study tape, the human gold standard detected 107 MES, with 93 MES having an intensity of ≥7 dB. The software detected 81 and 77 MES, respectively. Using the 7 dB intensity threshold, the software had no false positives and 16 false negatives. The κ value between the human gold standard and the software was 0.91, the proportion of specific agreement was 0.83. Conclusions: the tested algorithm provides a reliable method for automated on-line microemboli detection after CEA. This makes monitoring of the effectiveness of antiplatelet agents in the prevention of stroke after CEA more practicable.Eur J Vasc Endovasc Surg 25, 262–266 (2003

    Middle cerebral artery anatomy and characteristics of embolic signals : a dual gate computer simulation study

    No full text
    In terms of microembolic signal (MES) detection, the anatomy of the middle cerebral artery (MCA) mainstem has only scarcely been considered. The vessel itself, however, could be at least partly responsible for the enormous variation when calculating the essential time difference (¿t) values of MES using the dual-gate technique. Therefore, we studied the time characteristics of MES in a computer simulation applying an anatomically realistic vessel and a dual-gate TCD approach. Three different MCA anatomies and two MES to blood intensities were simulated as well as two different sample volume settings. The MES length (proximal sample volume t1; distal sample volume t2) and ¿t were calculated for different angles of insonation and sample volume depths. The calculations of the time characteristics of MES showed extreme variation, with only modest changes of the insonation angle (t1 4–34 ms; ¿t 9–27 ms) or the sample volume depth (t1 7–27 ms; ¿t 6–32 ms). The variation could be considerably reduced with modified TCD settings i.e., a shorter gate separation combined with a shorter receiver gate time in the distal sample volume (¿t with changing insonation angles 6–19 ms; ¿t with changing insonation depths 13–17 ms). These results not only urge us to a cautious interpretation of the properties of single MES, but also contribute to an understanding of the marked ¿t variation using the dual-gate technique

    Orthogonal B-Mode Evaluation of Common Carotid Artery Plaques Reveals the Absence of Outward Remodeling

    No full text
    Item does not contain fulltextTo properly assess morphologic and dynamic parameters of arteries and plaques, we propose the concept of orthogonal distance measurements, that is, measurements made perpendicular to the local lumen axis rather than along the ultrasound beam (vertical direction for a linear array). The aim of this study was to compare orthogonal and vertical artery and lumen diameters at the site of a plaque in the common carotid artery (CCA). Moreover, we investigated the interrelationship of orthogonal diameters and plaque size and the association of artery parameters with plaque echogenicity. In 29 patients, we acquired a longitudinal B-mode ultrasound recording of plaques at the posterior CCA wall. After semi-automatic segmentation of end-diastolic frames, diameters were extracted orthogonally along the lumen axis. To establish inter-observer variability of diameters obtained at the location of maximal plaque thickness, a second observer repeated the analysis (subset N = 21). Orthogonal adventitia-adventitia and lumen diameters could be determined with good precision (coefficient of variation: 1%-5%. However, the precision of the change in lumen diameter from diastole to systole (distension) at the site of the plaque was poor (21%-50%). The orthogonal lumen diameter was significantly smaller than the vertical lumen diameter (p <0.001). Surprisingly, the plaques did not cause outward remodeling, that is, a local increase in adventitia-adventitia distance at the site of the plaque. The intra- and inter-observer precision of diastolic-systolic plaque compression was poor and of the same order as the standard deviation of plaque compression. The orthogonal relative lumen distension was significantly lower for echogenic plaques, indicating a higher stiffness, than for echolucent plaques (p <0.01). In conclusion, we illustrated the feasibility of extracting orthogonal CCA and plaque dimensions, albeit that the proposed approach is inadequate to quantify plaque compression

    Standard B-Mode Ultrasound Measures Local Carotid Artery Characteristics as Reliably as Radiofrequency Phase Tracking in Symptomatic Carotid Artery Patients

    No full text
    Item does not contain fulltextLocal arterial stiffness can be assessed with high accuracy and precision by measuring arterial distension on the basis of phase tracking of radiofrequency ultrasound signals acquired at a high frame rate. However, in clinical practice, B-mode ultrasound registrations are made at a low frame rate (20-50 Hz). We compared the accuracy and intra-subject precision of edge tracking and phase tracking distension in symptomatic carotid artery patients. B-mode ultrasound recordings (40 mm, 37 fps) and radiofrequency recordings (31 lines covering 29 mm, 300 fps) were acquired from the left common carotid artery of 30 patients (aged 45-88 y) with recent cerebrovascular events. To extract the distension, semi-automatic echo edge and phase tracking algorithms were applied to B-mode and radiofrequency recordings, respectively. Both methods exhibited a similar intra-subject precision for distension (standard deviation = 44 mum and 47 mum, p = 0.66) and mean distension (difference: -6 +/- 69 mum, p = 0.67). Intra-subject distension inhomogeneity tends to be larger for edge tracking (difference: 15 +/- 35 mum, p = 0.04). Standard B-mode scanners are suitable for measuring local artery characteristics in symptomatic carotid artery patients with good precision and accuracy

    Single M-Line Is as Reliable as Multiple M-Line Ultrasound for Carotid Artery Screening

    No full text
    Purpose: Carotid artery properties can be evaluated with high accuracy and reproducibility using multiple M-line ultrasound. However, the cost of multiple M-line-based imaging modalities and the extensive operator expertise requirements hamper the large-scale application for arterial properties assessment, particularly in resource-constrained settings. This study is aimed to assess the performance of a single M-line approach as an affordable and easy-to-use alternative to multiple M-line imaging for screening purposes. Methods: We used triplicate longitudinal common carotid artery (CCA) ultrasound recordings (17 M-lines covering about 16 mm, at 500 frames per second) of 500 subjects from The Maastricht Study to assess the validity and reproducibility of a single against multiple M-line approach. The multiple M-line measures were obtained by averaging over all available 17 lines, whereas the middle M-line was used as a proxy for the single M-line approach. Results: Diameter, intima-media thickness (IMT), and Young's elastic modulus (YEM) were not significantly different between the single and multiple M-line approaches (p > 0.07). Distension and distensibility coefficient (DC) did differ significantly (p < 0.001), however, differences were technically irrelevant. Similarly, Bland-Altman analysis revealed good agreement between the two approaches. The single M-line approach, compared to multiple M-line, exhibited an acceptable reproducibility coefficient of variation (CV) for diameter (2.5 vs. 2.2%), IMT (11.9 vs. 7.9%), distension (10 vs. 9.4%), DC (10.9 vs. 10.2%), and YEM (26.5 vs. 20.5%). Furthermore, in our study population, both methods showed a similar capability to detect age-related differences in arterial stiffness. Conclusion: Single M-line ultrasound appears to be a promising tool to estimate anatomical and functional CCA properties with very acceptable validity and reproducibility. Based on our results, we might infer that image-free, single M-line tools could be suited for screening and for performing population studies in low-resource settings worldwide. Whether the comparison between single and multiple M-line devices will yield similar findings requires further study