3,319 research outputs found

    All-Sky spectrally matched UBVRI-ZY and u'g'r'i'z' magnitudes for stars in the Tycho2 catalog

    Full text link
    We present fitted UBVRI-ZY and u'g'r'i'z' magnitudes, spectral types and distances for 2.4M stars, derived from synthetic photometry of a library spectrum that best matches the Tycho2 BtVt, NOMAD Rn and 2MASS JHK_{2/S} catalog magnitudes. We present similarly synthesized multi-filter magnitudes, types and distances for 4.8M stars with 2MASS and SDSS photometry to g<16 within the Sloan survey region, for Landolt and Sloan primary standards, and for Sloan Northern (PT) and Southern secondary standards. The synthetic magnitude zeropoints for BtVt, UBVRI, ZvYv, JHK_{2/S}, JHK_{MKO}, Stromgren uvby, Sloan u'g'r'i'z' and ugriz are calibrated on 20 calspec spectrophotometric standards. The UBVRI and ugriz zeropoints have dispersions of 1--3%, for standards covering a range of color from -0.3 < V-I < 4.6; those for other filters are in the range 2--5%. The spectrally matched fits to Tycho2 stars provide estimated 1-sigma errors per star of ~0.2, 0.15, 0.12, 0.10 and 0.08 mags respectively in either UBVRI or u'g'r'i'z'; those for at least 70% of the SDSS survey region to g<16 have estimated 1-sigma errors per star of ~0.2, 0.06, 0.04, 0.04, 0.05 in u'g'r'i'z' or UBVRI. The density of Tycho2 stars, averaging about 60 stars per square degree, provides sufficient stars to enable automatic flux calibrations for most digital images with fields of view of 0.5 degree or more. Using several such standards per field, automatic flux calibration can be achieved to a few percent in any filter, at any airmass, in most workable observing conditions, to facilitate inter-comparison of data from different sites, telescopes and instruments.Comment: 36 pages, 30 figures, 3 printed tables, several electronic tables, accepted PASP Dec 201

    The Orbital Period of the Optical/X-Ray Burster X1735-444 (V926 Sco)

    Get PDF
    We present extensive CCD photometry of the optical counterpart of X1735–444 which reveals the orbital period of the system. It is periodically variable with a period of 4.654 hr and a full amplitude of 0.15 mag. The mean modulation is quasi-sinusoidal; there are, however, also significant intrinsic deviations from the mean light curve

    Calculating the Expected Value of Sample Information in Practice: Considerations from Three Case Studies

    Full text link
    Investing efficiently in future research to improve policy decisions is an important goal. Expected Value of Sample Information (EVSI) can be used to select the specific design and sample size of a proposed study by assessing the benefit of a range of different studies. Estimating EVSI with the standard nested Monte Carlo algorithm has a notoriously high computational burden, especially when using a complex decision model or when optimizing over study sample sizes and designs. Therefore, a number of more efficient EVSI approximation methods have been developed. However, these approximation methods have not been compared and therefore their relative advantages and disadvantages are not clear. A consortium of EVSI researchers, including the developers of several approximation methods, compared four EVSI methods using three previously published health economic models. The examples were chosen to represent a range of real-world contexts, including situations with multiple study outcomes, missing data, and data from an observational rather than a randomized study. The computational speed and accuracy of each method were compared, and the relative advantages and implementation challenges of the methods were highlighted. In each example, the approximation methods took minutes or hours to achieve reasonably accurate EVSI estimates, whereas the traditional Monte Carlo method took weeks. Specific methods are particularly suited to problems where we wish to compare multiple proposed sample sizes, when the proposed sample size is large, or when the health economic model is computationally expensive. All the evaluated methods gave estimates similar to those given by traditional Monte Carlo, suggesting that EVSI can now be efficiently computed with confidence in realistic examples.Comment: 11 pages, 3 figure

    Judgements of Solomon: anxieties and defences of social workers involved in care proceedings

    Get PDF
    Evidence from focus group discussions with social workers in child care and child protection was collected for a research project exploring decision-making in care proceedings and seeking a better understanding of the causes of delay in the process. Here this material is used to examine social workers’ feelings about their work and to explore the anxieties they expressed. Isabel Menzies’s work on containing anxiety in institutions is used to provide a conceptual framework for thinking about the ways in which individuals’ unconscious defences against anxiety may affect the structure, policies and practices of the organization in which they work. It is suggested that this dimension needs to be taken into account in understanding difficulties which arise in putting policy into practice

    Spitzer Space Telescope spectral observations of AGB stars in the Fornax dwarf spheroidal galaxy

    Get PDF
    We have observed five carbon-rich AGB stars in the Fornax dwarf spheroidal (dSph) galaxy, using the Infrared Spectrometer on board the Spitzer Space Telescope. The stars were selected from a near-infrared survey of Fornax and include the three reddest stars, with presumably the highest mass-loss rates, in that galaxy. Such carbon stars probably belong to the intermediate-age population (2-8 Gyr old and metallicity of [Fe/H] -1) of Fornax. The primary aim of this paper is to investigate mass-loss rate, as a function of luminosity and metallicity, by comparing AGB stars in several galaxies with different metallicities. The spectra of three stars are fitted with a radiative transfer model. We find that mass-loss rates of these three stars are 4-7x10^-6 Msun yr-1. The other two stars have mass-loss rates below 1.3x10^-6 Msun yr-1. We find no evidence that these rates depend on metallicity, although we do suggest that the gas-to-dust ratio could be higher than at solar metallicity, in the range 240 to 800. The C2H2 bands are stronger at lower metallicity because of the higher C/O ratio. In contrast, the SiC fraction is reduced at low metallicity, due to low silicon abundance. The total mass-loss rate from all known carbon-rich AGB stars into the interstellar medium of this galaxy is of the order of 2x10^-5 Msun yr-1. This is much lower than that of the dwarf irregular galaxy WLM, which has a similar visual luminosity and metallicity. The difference is attributed to the younger stellar population of WLM. The suppressed gas-return rate to the ISM accentuates the difference between the relatively gas-rich dwarf irregular and the gas-poor dwarf spheroidal galaxies. Our study will be useful to constrain gas and dust recycling processes in low metallicity galaxies.Comment: MNRAS accepte

    OT 060420: A Seemingly Optical Transient Recorded by All-Sky Cameras

    Get PDF
    We report on a ~5th magnitude flash detected for approximately 10 minutes by two CONCAM all-sky cameras located in Cerro Pachon - Chile and La Palma - Spain. A third all-sky camera, located in Cerro Paranal - Chile did not detect the flash, and therefore the authors of this paper suggest that the flash was a series of cosmic-ray hits, meteors, or satellite glints. Another proposed hypothesis is that the flash was an astronomical transient with variable luminosity. In this paper we discuss bright optical transient detection using fish-eye all-sky monitors, analyze the apparently false-positive optical transient, and propose possible causes to false optical transient detection in all-sky cameras.Comment: 7 figures, 3 tables, accepted PAS

    Limb-Darkening of a K Giant in the Galactic Bulge: PLANET Photometry of MACHO 97-BLG-28

    Get PDF
    We present the PLANET photometric dataset for the binary-lens microlensing event MACHO 97-BLG-28 consisting of 696 I and V-band measurements, and analyze it to determine the radial surface brightness profile of the Galactic bulge source star. The microlensed source, demonstrated to be a K giant by our independent spectroscopy, crossed the central isolated cusp of the lensing binary, generating a sharp peak in the light curve that was well-resolved by dense (3 - 30 minute) and continuous monitoring from PLANET sites in Chile, South Africa, and Australia. Our modeling of these data has produced stellar profiles for the source star in the I and V bands that are in excellent agreement with those predicted by stellar atmospheric models for K giants. The limb-darkening coefficients presented here are the first derived from microlensing, among the first for normal giants by any technique, and the first for any star as distant as the Galactic bulge. Modeling indicates that the lensing binary has a mass ratio q = 0.23 and an (instantaneous) separation in units of the angular Einstein ring radius of d = 0.69 . For a lens in the Galactic bulge, this corresponds to a typical stellar binary with a projected separation between 1 and 2 AU. If the lens lies closer, the separation is smaller, and one or both of the lens objects is in the brown dwarf regime. Assuming that the source is a bulge K2 giant at 8 kpc, the relative lens-source proper motion is mu = 19.4 +/- 2.6 km/s /kpc, consistent with a disk or bulge lens. If the non-lensed blended light is due to a single star, it is likely to be a young white dwarf in the bulge, consistent with the blended light coming from the lens itself.Comment: 32 Pages, including 1 table and 9 postscript figures. (Revised version has slightly modified text, corrected typo, and 1 new figure.) Accepted for publication in 1999 Astrophysical Journal; data are now available at http://www.astro.rug.nl/~plane
    • …
    corecore