    Ectopic bone formation in cell-seeded poly(ethylene oxide)/poly(butylene terephthalate) copolymer scaffolds of varying porosity

    Get PDF
    Scaffolds from poly(ethylene oxide) and poly(butylene terephthalate), PEOT/PBT, with a PEO molecular weight of 1,000 and a PEOT content of 70 weight% (1000PEOT70PBT30) were prepared by leaching salt particles (425–500 μm). Scaffolds of 73.5, 80.6 and 85.0% porosity were treated with a CO2 gas plasma and seeded with rat bone marrow stromal cells (BMSCs). After in vitro culture for 7 days (d) in an osteogenic medium the scaffolds were subcutaneously implanted for 4 weeks in nude mice. Poly(d, l-lactide) (PDLLA) and biphasic calcium phosphate (BCP) scaffolds were included as references. After 4 weeks (wks) all scaffolds showed ectopic formation of bone and bone marrow. For the scaffolds of different porosities, no significant differences were observed in the relative amounts of bone (7–9%) and bone marrow (6–11%) formed, even though micro computed tomography (μ-CT) data showed considerable differences in accessible pore volume and surface area. 1000PEOT70PBT30 scaffolds with a porosity of 85% could not maintain their original shape in vivo. Surprisingly, 1000PEOT70PBT30 scaffolds with a porosity of 73.5% showed cartilage formation. This cartilage formation is most likely due to poorly accessible pores in the scaffolds, as was observed in histological sections. μ-CT data showed a considerably smaller accessible pore volume (as a fraction of the total volume) than in 1000PEOT70PBT30 scaffolds of 80.6 and 85.0% porosity. BMSC seeded PDLLA (83.5% porosity) and BCP scaffolds (29% porosity) always showed considerably more bone and bone marrow formation (bone marrow formation is approximately 40%) and less fibrous tissue ingrowth than the 1000PEOT70PBT30 scaffolds. The scaffold material itself can be of great influence. In more hydrophobic and rigid scaffolds like the PDLLA or BCP scaffolds, the accessibility of the pore structure is more likely to be preserved under the prevailing physiological conditions than in the case of hydrophilic 1000PEOT70PBT30 scaffolds. Scaffolds prepared from other PEOT/PBT polymer compositions, might prove to be more suited

    Porous PEOT/PBT scaffolds for bone tissue engineering: Preparation, characterization, and in vitro bone marrow cell culturing

    Get PDF
    The preparation, characterization, and in vitro bone marrow cell culturing on porous PEOT/PBT copolymer scaffolds are described. These scaffolds are meant for use in bone tissue engineering. Previous research has shown that PEOT/PBT copolymers showed in vivo degradation, calcification, and bone bonding. Despite this, several of these copolymers do not support bone marrow cell growth in vitro. Surface modification, such as gas-plasma treatment, is needed to improve the in vitro cell attachment. Porous structures were prepared using a freeze-drying and a salt-leaching technique, the latter one resulting in highly porous interconnected structures of large pore size. Gas-plasma treatment with CO2 generated a surface throughout the entire structure that enabled bone marrow cells to attach. The amount of DNA was determined as a measure for the amount of cells present on the scaffolds. No significant effect of pore size on the amount of DNA present was seen for scaffolds with pore sizes between 250-1000 m. Light microscopy data showed cells in the center of the scaffolds, more cells were observed in the scaffolds of 425-500 m and 500-710 m pore size compared to the ones with 250-425 m and 710-1000 m pore

    Design of segmented poly(ether ester) materials and structures for the tissue engineering of bone

    Get PDF
    In this study, PEOT/PBT segmented copolymers of different compositions have been evaluated as possible scaffold materials for the tissue engineering of bone. By changing the composition of PEOT/PBT copolymers, very different mechanical and swelling behaviors are observed. Tensile strengths vary from 8 to 23 MPa and elongations at break from 500 to 1300%. Water-uptake ranges from 4 up to as high as 210%. The in vitro degradation of PEOT/PBT copolymers occurs both by hydrolysis and oxidation. In both cases degradation is more rapid for copolymers with high PEO content. PEOT/PBT scaffolds with varying porosities and pore sizes have been prepared by molding and freeze-drying techniques in combination with particulate-leaching. The most hydrophilic PEOT/PBT copolymers did not sustain goat bone marrow cell adhesion and growth. However, surface modification by gas plasma treatment showed a very much improved polymer–cell interaction for all PEOT/PBT copolymer compositions. Their mechanical properties, degradability and ability to sustain bone marrow cell growth make PEOT/PBT copolymers excellent materials for bone tissue engineering
    corecore