14 research outputs found

    Non-exclusion separation techniques for polyamides

    No full text
    +224hlm.;24c

    A new DBS card with spot sizes independent of the hematocrit value of blood

    No full text
    DBS cards have been a big promise for decades. However, blood with low hematocrit (Ht) values results on regular cellulose-based DBS cards in larger spot sizes, compared with blood with high Ht-values. A new material has been developed to solve this problem. Results: This material, based on hydrophilic-coated woven polyester fibers, shows spot sizes independent of the Ht-value of blood. Homogeneity over the spot is within 10% RSD. Conclusion: Quantitative measurements over a broad Ht range show nonbiased results compared with whole spot analysis. The cards are experienced as reproducible, robust and easy to use on aspects of punchability and extractability.</p

    A new DBS card with spot sizes independent of the hematocrit value of blood

    No full text
    DBS cards have been a big promise for decades. However, blood with low hematocrit (Ht) values results on regular cellulose-based DBS cards in larger spot sizes, compared with blood with high Ht-values. A new material has been developed to solve this problem. Results: This material, based on hydrophilic-coated woven polyester fibers, shows spot sizes independent of the Ht-value of blood. Homogeneity over the spot is within 10% RSD. Conclusion: Quantitative measurements over a broad Ht range show nonbiased results compared with whole spot analysis. The cards are experienced as reproducible, robust and easy to use on aspects of punchability and extractability

    Adduct-ion formation in trapped ion mobility spectrometry as a potential tool for studying molecular structures and conformations

    No full text
    Recent developments in the field of ion mobility spectrometry provide new possibilities to explore and understand gas-phase ion chemistry. In this study, hyphenated trapped ion mobility spectrometry-mass spectrometry (TIMS-MS) was applied to investigate analyte ion mobility as function of adduct ion formation for twelve pharmaceutically relevant molecules, and for tetrahydrocannabinol (THC) and its isomer cannabidiol (CBD). Samples were introduced by direct infusion and ions were generated with positive electrospray ionization (ESI+) observing protonated and sodiated ions. Measurements were performed with and without addition of cesium-, lithium-, silver- and sodium ions to the samples. For the tested compounds, metal adduct ions with the same m/z but with different mobility and collision cross section (CCSs) were observed, indicating different molecular conformations. Formation of analyte dimers was also observed, which could be associated with molecular geometry of the compounds. By optimizing the range and speed of the electric field gradient and ramp, respectively, the separation of THC and CBD was achieved by employing the adduct formation. This study demonstrates that the favorable resolution of TIMS combined with the ability to detect weakly bound counter ions is a valuable means for rapid detection, separation and structural assignment of molecular isomers and analyte conformations

    Adduct ion formation as a tool for the molecular structure assessment of ten isomers in traveling wave and trapped ion mobility spectrometry

    No full text
    Rationale The separation of isomeric compounds with major differences in their physiochemical and pharmacokinetic properties is of particular importance in pharmaceutical R&D. However, the structural assessment and separation of these compounds with current analytical techniques and methods are still a challenge. In this study, we describe strategies to separate the various structural and stereo-isomers. Methods The separation of ten structural and stereo-isomers was investigated using Trapped and Travelling Wave ion mobility spectrometry (TIMS and TWIMS). Different strategies including adduct ion formation with Na, Li, Ag and Cs as well as fragmentation before and after the ion mobility cell were applied to separate the isomeric compounds. Results All the counter ions (in particular Na) strongly coordinated with the test analytes in all the IMS systems. The highest resolving power was achieved for the sodium and lithium adducts using TIMS-time-of-flight (TOF). However, some separation was attained on a Synapt HDMS system with its unique potential to monitor the ion mobility of the product ions. The elution order of the adduct ions was the same in all instruments, in which, unexpectedly, the para-substituted isomer of the [M + Na](+) species had the lowest collision cross section followed by the meta- and ortho-isomers. Conclusions The formation of adduct ions could facilitate the separation of structural and even stereo-isomers by generating different molecular conformations. In addition, fragmenting isomers before or after the ion mobility cell is a valuable strategy to separate and also to assess the structures of adducts and different conformers

    Comprehensive Ion Mobility Calibration: Poly(ethylene oxide) Polymer Calibrants and General Strategies

    Full text link
    Ion Mobility (IM) is now a well-established and fast analytical technique. The IM hardware is constantly being improved, especially in terms of the resolving power. The Drift Tube (DTIMS), the Traveling Wave (TWIMS), and the Trapped Ion Mobility Spectrometry (TIMS) coupled to mass spectrometry are used to determine the Collision Cross-Sections (CCS) of ions. In analytical chemistry, the CCS is approached as a descriptor for ion identification and it is also used in physical chemistry for 3D structure elucidation with computational chemistry support. The CCS is a physical descriptor extracted from the reduced mobility (K0) measurements obtainable only from the DTIMS. TWIMS and TIMS routinely require a calibration procedure to convert measured physical quantities (drift time for TWIMS and elution voltage for TIMS) into CCS values. This calibration is a critical step to allow inter-instrument comparisons. The previous calibrating substances lead to large prediction bands and introduced rather large uncertainties during the CCS determination. In this paper, we introduce a new IM calibrant (CCS and K0) using singly charged sodium adducts of poly(ethylene oxide) monomethyl ether (CH3O-PEO-H) for positive ionization in both helium and nitrogen as drift gas. These singly charged calibrating ions make it possible to determine the CCS/K0 of ions having higher charge states. The fitted calibration plots exhibit larger coverage with less data scattering and significantly improved prediction bands and uncertainties. The reasons for the improved CCS/K0 accuracy, advantages and limitations of the calibration procedures are also discussed. A generalized IM calibration strategy is suggested

    Probing Polyester Branching by Hybrid Trapped Ion-Mobility SpectrometryTandem Mass Spectrometry

    No full text
    [Image: see text] Trapped ion-mobility spectrometry combined with quadrupole time-of-flight mass spectrometry (TIMS-QTOFMS) was evaluated as a tool for resolving linear and branched isomeric polyester oligomers. Solutions of polyester samples were infused directly into the ion source employing electrospray ionization (ESI). TIMS-MS provides both mobility and m/z data on the formed ions, allowing construction of extracted-ion mobilograms (EIMs). EIMs of polyester molecules showed multimodal patterns, indicating conformational differences among isomers. Subsequent TIMS-MS/MS experiments indicated mobility differences to be caused by (degree of) branching. These assignments were supported by liquid chromatography-TIMS-MS/MS analysis, confirming that direct TIMS-MS provided fast (500 ms/scan) distinction between linear and branched small oligomers. Observing larger oligomers (up to 3000 Da) using TIMS required additional molecular charging to ensure ion entrapment within the mobility window. Molecular supercharging was achieved using m-nitrobenzyl alcohol (NBA). The additional charges on the oligomer structures enhanced mobility separation of isomeric species but also added to the complexity of the obtained fragmentation mass spectra. This complexity could be partly reduced by post-TIMS analyte-decharging applying collision-induced dissociation (CID) prior to Q1 with subsequent isolation of the singly charged ions for further fragmentation. The as-obtained EIM profiles were still quite complex as larger molecules possess more possible structural isomers. Nevertheless, distinguishing between linear and symmetrically branched oligomers was possible based on measured differences in collisional cross sections (CCSs). The established TIMS-QTOFMS approach reliably allows branching information on isomeric polyester molecules up to 3000 Da to be obtained in less than 1 min analysis time
    corecore