748 research outputs found
Microwave growth from the beam breakup instability in longâpulse electron beam experiments
The beam breakup (BBU) instability has been investigated in highâcurrent, longâpulse electron beams propagating through microwave cavities. Experiments are performed using a relativistic electronâbeam generator with diode parameters: 0.7â0.8 MV, 1â15 kA, and 0.5â1.5 ÎŒs. The magnitude of the solenoidal magnetic field places these experiments in an intermediate regime between strong focusing and weak focusing. The electronâbeam transport system consists of ten identical pillbox cavities each containing a small microwave loop antenna designed to detect the TM110 beam breakup mode. The TM110 microwave mode is primed in the first cavity by a magnetron tuned to the resonance frequency of 2.5 GHz. The BBU instability growth is measured through the amplification of the 2.5 GHz microwaves between the second and tenth cavities. Strong growth (25â38 dB) of the TM110 microwave signal is observed when the initial cavity is primed exactly on resonance, with a rapid decrease of the growth rate offâresonance. The magnitude of microwave growth is consistent with the predictions of BBU theory.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/69350/2/APPLAB-61-6-642-1.pd
The beam breakup instability in quadrupole and solenoidal electronâbeam transport systems
Dispersion relations are derived to determine the growth rate, dominant wavelength, and group velocity of disturbances caused by the beam breakup instability. Considerations include weak and strong focusing, xây coupling in solenoidal transport, the spacing of accelerator cavities, and periodically pulsed beams. Beam breakup growth is minimum when the cavity spacing equals an integral number of halfâbetatron wavelengths for quadrupole focusing, and an integral number of betatron wavelengths for solenoidal focusing. Minimum growth is also found for periodic pulses separated by an integral number of halfâperiods of the TM110 cavity mode. Expressions for beam breakup growth at the minima are obtained.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/71286/2/JAPIAU-71-7-3091-1.pd
Beam breakup growth and reduction experiments in longâpulse electron beam transport
The results of an experimental program whose sole objective is to investigate the cumulative beam breakup instability (BBU) in electron beam accelerators are presented. The BBU growth rate scalings are examined with regard to beam current, focusing field, cavity Q, and propagation distance. A microwave cavity array was designed and fabricated to excite and measure the cumulative BBU resulting from beam interactions with the deflecting TM110 cavity mode. One phase of this experiment used high Q(â1000) cavities with relatively large frequency spread (Îf/f0â0.1%). The observed TM110 mode microwave growth between an upstream (second) and a downstream (tenth) cavity indicated BBU growth of 26 dB for an electron beam of kinetic energy of 750 keV, 45 A, and focused by a 1.1 kG solenoidal field. At beam currents of less than 100 A the experiments agreed well with a twoâdimensional continuum theory; the agreement was worse at higher beam currents (âł100 A) due to beam loading. The secondâphase experiments used lower Q(â200) cavities with relatively low frequency spread (Îf/f0â0.03%). Theory and experiment agreed well for beam currents up to 220 A. Distance scaling experiments were also performed by doubling the propagation length. Instability growth reduction experiments using the technique of external cavity coupling resulted in a factor of four decrease in energy in BBU growth when seven internal beam cavities were coupled by microwave cable to seven identical external dummy cavities. A theory invoking power sharing between the internal beam cavities and the external dummy cavities was used to explain the experimental reduction with excellent agreement using an equivalent circuit model.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/71080/2/JAPIAU-75-3-1258-1.pd
Measurement of longâpulse relativistic electron beam perpendicularâ toâparallel velocity ratio by Cerenkov emission and radiation darkening on a glass plate
We report measurements of the ratio of the perpendicular velocity to the parallel velocity, α= vâ„â/vâ„, of a relativistic electron beam gyrating in a magnetic field by the use of (1) Cerenkov emission from a glass plate, detected by a gated microchannel plate image intensifier camera, and (2) electronâbeamâinduced radiation darkening pattern on the same glass plate. The measurements are based on a direct determination of the Larmor radius of an electron beam of known energy. Experiments were performed on a longâpulse electron beam accelerator with eâbeam diode parameters: VD = 0.6â0.9 MV, pulse length=0.5â1 ÎŒs, ID = 1â10 kA. The experimental value of α agrees with simulation results from particle trajectory codes as well as theoretical predictions from Buschâs theorem and adiabatic theory.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/70360/2/RSINAK-63-2-1671-1.pd
Radio frequency plasma processing effects on the emission characteristics of a MeV electron beam cathode
Experiments have proven that surface contaminants on the cathode of an electron beam diode influence electron emission current and impedance collapse. This letter reports on an investigation to reduce parasitic cathode current loss and to increase high voltage hold off capabilities by reactive sputter cleaning of contaminants. Experiments have characterized effective radio frequency (rf) plasma processing protocols for high voltage anodeâcathode (AâK) gaps using a two-stage argon/oxygen and argon rf plasma discharge. Time-resolved optical emission spectroscopy measures contaminant (hydrogen) and bulk cathode (aluminum) plasma emission versus transported axial electron beam current turn on. Experiments were performed at accelerator parameters: V = â0.7V=â0.7 to â1.1âMV,â1.1MV, I(diode)=3â30âkA,I(diode)=3â30kA, and pulse length=0.4â1.0âÎŒs.length=0.4â1.0ÎŒs. Experiments using a two-stage low power (100 W) argon/oxygen rf discharge followed by a higher power (200 W) pure argon rf discharge yielded an increase in cathode turn-on voltage required for axial current emission from 662±174âkV662±174kV to 981±97âkV.981±97kV. The turn-on time of axial current was increased from 100±22100±22 to 175±42âns.175±42ns. © 1999 American Institute of Physics.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/69353/2/APPLAB-75-1-31-1.pd
Deflection of carbon dioxide laser and heliumâneon laser beams in a longâpulse relativistic electron beam diode
Deflection of carbon dioxide and heliumâneon laser beams has been used to measure plasma and neutral density gradients during the operating mode and after the shorting time of a longâpulse fieldâemission electron beam diode. Plasma density gradients of (1014â1015) cmâ4 were observed throughout the diode during the final microsecond of the 2â3 ÎŒs electron beam pulse. The neutral density gradient was less than 1Ă1018 cmâ4 during the electron beam pulse. Upon diode shorting, neutral density gradients increased to (1018â1019) cmâ4 over âŒ1 ÎŒs, and decayed over many microseconds. Plasma density gradients of âŒ1015 cmâ4 were also observed after shorting. These experiments demonstrate the value of carbonâdioxide laser and heliumâneon laser deflection for diagnosing plasma and neutral particles in longâpulse electron beam diodes.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/70220/2/RSINAK-62-7-1776-1.pd
Toward Improved Observing of the Rapidly Changing Arctic Ocean
Arctic Observing Summit (April 30 â May 2, 2013, Vancouver, Canada); AON statementIn order to observe and understand the Arctic Ocean and its response to climate change, the traditional approach of acquiring observations when and where the Arctic is accessible has to be enhanced with multi-faceted measurement systems operating autonomously to provide year-round information in real time. The major goal of such a network of autonomous sensors is to measure and monitor physical, chemical and biological parameters in the atmosphere, sea ice and ocean on at least daily intervals
Histamine as a marker for hydroxyl radicals
During inflammation an influx of neutrophils and release of mediators from mast cells (such as histamine) take place. The stimulated neutrophils can produce reactive oxygen species (ROS). One of these ROS is the highly reactive hydroxyl radical (OH.). It would be interesting to be able to quantify the extent of ROS formation. We investigated if histamine which is present at the inflammation site can serve as an endogenous marker for the formation of OH.. We found that histamine after incubation with OH. gave two distinct products in our HPLC system. One of the products gave the same characteristics as the synthesized 2-imidazolone derivative of histamine. This suggests that this derivative will be formed when histamine is incubated with OH.
Temporal and spatial variability in stable isotope ratios of SPM link to local hydrography and longer term SPM averages suggest heavy dependence of mussels on nearshore production
Temporal changes in hydrography affect suspended particulate matter (SPM) composition and distribution in coastal systems, potentially influencing the diets of suspension feeders. Temporal variation in SPM and in the diet of the mussel Perna perna, were investigated using stable isotope analysis. The ÎŽ13C and ÎŽ15 N ratios of SPM, mussels and macroalgae were determined monthly, with SPM samples collected along a 10 km onshoreâoffshore transect, over 14 months at Kenton-on-Sea, on the south coast of South Africa. Clear nearshore (0 km) to offshore (10 km) carbon depletion gradients were seen in SPM during all months and extended for 50 km offshore on one occasion. Carbon enrichment of coastal SPM in winter (JuneâAugust 2004 and May 2005) indicated temporal changes in the nearshore detrital pool, presumably reflecting changes in macroalgal detritus, linked to local changes in coastal hydrography and algal seasonality. Nitrogen patterns were less clear, with SPM enrichment seen between July and October 2004 from 0 to 10 km. Nearshore SPM demonstrated cyclical patterns in carbon over 24-h periods that correlated closely with tidal cycles and mussel carbon signatures, sampled monthly, demonstrated fluctuations that could not be correlated to seasonal or monthly changes in SPM. Macroalgae showed extreme variability in isotopic signatures, with no discernable patterns. IsoSource mixing models indicated over 50% reliance of mussel tissue on nearshore carbon, highlighting the importance of nearshore SPM in mussel diet. Overall, carbon variation in SPM at both large and small temporal scales can be related to hydrographic processes, but is masked in mussels by long-term isotope integration
- âŠ