186 research outputs found

    Clinical Relevance of Studies on the Accuracy of Visual Inspection for Detecting Caries Lesions: A Systematic Review

    Get PDF
    Although visual inspection is the most commonly used method for caries detection, and consequently the most investigated, studies have not been concerned about the clinical relevance of this procedure. Therefore, we conducted a systematic review in order to perform a critical evaluation considering the clinical relevance and methodological quality of studies on the accuracy of visual inspection for assessing caries lesions. Two independent reviewers searched several databases through July 2013 to identify papers/articles published in English. Other sources were checked to identify unpublished literature. The eligible studies were those which (1) assessed the accuracy of the visual method for detecting caries lesions on occlusal, approximal or smooth surfaces, in primary or permanent teeth, (2) used a reference standard, and (3) reported data about sample size and accuracy of the methods. Aspects related to clinical relevance and the methodological quality of the studies were evaluated. 96 of the 5,578 articles initially identified met the inclusion criteria. In general, most studies failed in considering some clinically relevant aspects: only 1 included study validated activity status of lesions, no study considered its prognosis, 79 studies did not consider a clinically relevant outcome, and only 1 evaluated a patient-centred outcome. Concerning methodological quality, the majority of the studies presented a high risk of bias in sample selection. In conclusion, studies on the accuracy of the visual method for caries detection should consider clinically relevant outcomes besides accuracy; moreover, they should be conducted with higher methodological quality, mainly regarding sample selection

    Correlates of accelerometer-assessed physical activity in pregnancy—The 2015 Pelotas (Brazil) Birth Cohort Study

    Get PDF
    Objective methods to measure physical activity (PA) have become available and widely used given the high degree of precision to evaluate PA. However, few studies have used accelerometers to measure PA during pregnancy, especially in low- and middle-income countries. We assessed overall PA, moderate, vigorous, and moderate-to-vigorous physical activity (MVPA) objectively measured among pregnant women and their correlates in a population-based study. PA was assessed for seven consecutive days using a raw triaxial wrist-worn accelerometer in women interviewed around 16 and 24 weeks of gestation in the 2015 Pelotas (Brazil) Birth Cohort Study. The average acceleration, which expresses overall PA, was presented in milli-g (1 mg = 0.001 g), and average time (min/day) spent in MVPA (>100 mg) was also analyzed in 5- and 10-min bouts. Analyses were performed using linear regression. In total, 2317 women were included in the analyses. Overall PA was 27.6 mg. Pregnant women spent on average 14 min/day in MVPA and 0.4 min in vigorous PA. Time spent in MVPA and total PA were inversely associated with years in school and income, and were lower among women receiving advice to not exercise. MVPA was also inversely associated with age, lower among women living with a partner, and higher among non-white women. The study indicated low levels of PA among pregnant women. The identified correlates may provide a framework to better understand factors influencing PA during pregnancy and thus inform future interventions

    How many days are needed to estimate wrist-worn accelerometry-assessed physical activity during the second trimester in pregnancy?

    Get PDF
    Background Objective methods to measure physical activity (PA) can lead to better cross-cultural comparisons, monitoring temporal PA trends, and measuring the effect of interventions. However, when applying this technology in field-work, the accelerometer data processing is prone to methodological issues. One of the most challenging issues relates to standardizing total wear time to provide reliable data across participants. It is generally accepted that at least 4 complete days of accelerometer wear represent a week for adults. It is not known if this same assumption holds true for pregnant women. Aim We assessed the optimal number of days needed to obtain reliable estimates of overall PA and moderate-to-vigorous physical activity (MVPA) during the 2nd trimester in pregnancy using a raw triaxial wrist-worn accelerometer. Methods Cross-sectional analyses were carried out in the antenatal wave of the 2015 Pelotas (Brazil) Birth Cohort Study. Participants wore the wrist ActiGraph wGT3X-BT accelerometer for seven consecutive days. The daily average acceleration, which indicated overall PA, was measured as milli-g (mg), and time spent in MVPA (minutes/day) was analyzed in 5-minute bouts. ANOVA and Kruskal-Wallis tests were used to compare variability across days of the week. Bland-Altman plots and the Spearman-Brown Prophecy Formula were applied to determine the reliability coefficient associated with one to seven days of measurement. Results Among 2,082 pregnant women who wore the accelerometer for seven complete days, overall and MVPA were lower on Sundays compared to other days of the week. Reliability of > = 0.80 to evaluate overall PA was reached with at least three monitoring days, whereas seven days were needed to estimate reliable measures of MVPA. Conclusions Our findings indicate that obtaining one week of accelerometry in adults is appropriate for pregnant women, particularly to obtain differences on weekend days and reliably estimate overall PA and MVPA

    Can we live in a self-tuning universe?

    Get PDF
    The self-tuning brane scenario is an attempt to solve the cosmological constant problem in the context of extra dimensions. Rather than making the vacuum energy small, this approach proceeds by removing the gravitational effect of vacuum energy on the expansion of the universe. Such behavior is only possible through changing the Friedmann equation of conventional cosmology, and we discuss difficulties in obtaining cosmological evolution compatible with observation in this context. Specific models considered include a bulk scalar field coupling to the brane via a conformal transformation of the brane metric, and via a rescaling of the brane volume element
    corecore