27,774 research outputs found

    Alternative antibody for the detection of CA125 antigen: a European multicenter study for the evaluation of the analytical and clinical performance of the Access (R) OV Monitor assay on the UniCel (R) Dxl 800 Immunoassay System

    Get PDF
    Background: Cancer antigen CA125 is known as a valuable marker for the management of ovarian cancer. Methods: The analytical and clinical performance of the Access OV Monitor Immunoassay System (Beckman Coulter) was evaluated at five different European sites and compared with a reference system, defined as CA125 on the Elecsys System (Roche Diagnostics). Results: Total imprecision (%CV) of the OV Monitor ranged between 3.1% and 8.8%, and inter-laboratory reproducibility between 4.7% and 5.0%. Linearity upon dilution showed a mean recovery of 100% (SD+8.1%). Endogenous interferents had no influence on OV Monitor levels (mean recoveries: hemoglobin 107%, bilirubin 103%, triglycericles 103%). There was no high-dose hook effect up to 27,193 kU/L. Clinical performance investigated in sera from 1811 individuals showed a good correlation between the Access OV Monitor and Elecsys CA125 (R = 0.982, slope = 0.921, intercept = + 1.951). OV Monitor serum levels were low in healthy individuals (n = 267, median = 9.7 kU/L, 95th percentile = 30.8 kU/L), higher in individuals with various benign diseases (n = 549, medians = 10.9-16.4 kU/L, 95th percentiles = 44.2-355 kU/L) and even higher in individuals suffering from various cancers (n = 995, medians= 12.4-445 kU/L; 95th percentiles = 53.4-4664 kU/L). Optimal diagnostic accuracy for cancer detection against the relevant benign control group by the OV Monitor was found for ovarian cancer {[}area under the curve (AUC) 0.898]. Results for the reference CA125 assay were comparable (AUC 0.899). Conclusions: The Access OV Monitor provides very good methodological characteristics and demonstrates an excellent analytical and clinical correlation with Elecsys CA125. The best diagnostic accuracy for the OV Monitor was found in ovarian cancer. Our results also suggest a clinical value of the OV Monitor in other cancers

    Metformin, Sulfonylureas, or Other Antidiabetes Drugs and the Risk of Lactic Acidosis or Hypoglycemia

    Get PDF
    OBJECTIVE: Lactic acidosis has been associated with use of metformin. Hypoglycemia is a major concern using sulfonylureas. The aim of this study was to compare the risk of lactic acidosis and hypoglycemia among patients with type 2 diabetes using oral antidiabetes drugs. RESEARCH DESIGN AND METHODS: This study is a nested case-control analysis using the U.K.-based General Practice Research Database to identify patients with type 2 diabetes who used oral antidiabetes drugs. Within the study population, all incident cases of lactic acidosis and hypoglycemia were identified, and hypoglycemia case subjects were matched to up to four control patients based on age, sex, practice, and calendar time. RESULTS: Among the study population of 50,048 type 2 diabetic subjects, six cases of lactic acidosis during current use of oral antidiabetes drugs were identified, yielding a crude incidence rate of 3.3 cases per 100,000 person-years among metformin users and 4.8 cases per 100,000 person-years among users of sulfonylureas. Relevant comorbidities known as risk factors for lactic acidosis could be identified in all case subjects. A total of 2,025 case subjects with hypoglycemia and 7,278 matched control subjects were identified. Use of sulfonylureas was associated with a materially elevated risk of hypoglycemia. The adjusted odds ratio for current use of sulfonylureas was 2.79 (95% CI 2.23–3.50) compared with current metformin use. CONCLUSIONS: Lactic acidosis during current use of oral antidiabetes drugs was very rare and was associated with concurrent comorbidity. Hypoglycemic episodes were substantially more common among sulfonylurea users than among users of metformin.Merck SA, Lyon, Franc

    Analytical and experimental investigation of sidelobe suppression techniques for reflector type spacecraft antenna Final technical report

    Get PDF
    Near axis sidelobe suppression techniques for circularly polarized reflector type spacecraft antenna

    Did the Bundesbank Follow a Taylor Rule? An Analysis Based on Real-Time Data

    Get PDF
    Using a real-time data set for German GDP over the period from 1973 to 1998 we calculate various measures of real-time output gaps and use these to calibrate and estimate Taylor-type reaction functions for the Bundesbank. Most of the reaction functions we find fit the Bundesbank´s actual policy, as represented by the short-run interest rate, quite well. In contrast to previous findings based on ex post revised data for the output gap, we find the reaction coefficients to resemble quite closely those originally proposed by Taylor for some of our real-time measures of the output gap. Broad monetary aggregates such as M3, in contrast, only played a small role for the Bundesbank´s interest rate decisions. Given the good record of the Bundesbank in fighting inflation, the results give support for the use of the Taylor rule for monetary policy.German real-time data; output gap; monetary policy rules

    Techniques, based on extremal subspaces, for improved reconstruction of signals from samples

    Get PDF
    Extremal subspaces techniques for reconstruction of signal from sample
    • …
    corecore