4 research outputs found

    Temperature-dependent magnetic particle imaging with multi-harmonic lock-in detection

    Full text link
    Advances in instrumentation and tracer materials are still required to enable sensitive and accurate 3D temperature monitoring by magnetic particle imaging. We have developed a magnetic particle imaging instrument to observe temperature variations using MPI, and discuss resolution dependence on temperature and harmonic number. Furthermore, we present a low noise approach using lock-in detection for temperature measurement, and discuss implications for a new detection modality of MPI.Comment: 26 pages, 17 figure

    Rapid Fabrication by Digital Light Processing 3D Printing of a SlipChip with Movable Ports for Local Delivery to Ex Vivo Organ Cultures

    No full text
    SlipChips are two-part microfluidic devices that can be reconfigured to change fluidic pathways for a wide range of functions, including tissue stimulation. Currently, fabrication of these devices at the prototype stage requires a skilled microfluidic technician, e.g., for wet etching or alignment steps. In most cases, SlipChip functionality requires an optically clear, smooth, and flat surface that is fluorophilic and hydrophobic. Here, we tested digital light processing (DLP) 3D printing, which is rapid, reproducible, and easily shared, as a solution for fabrication of SlipChips at the prototype stage. As a case study, we sought to fabricate a SlipChip intended for local delivery to live tissue slices through a movable microfluidic port. The device was comprised of two multi-layer components: an enclosed channel with a delivery port and a culture chamber for tissue slices with a permeable support. Once the design was optimized, we demonstrated its function by locally delivering a chemical probe to slices of hydrogel and to living tissue with up to 120 µm spatial resolution. By establishing the design principles for 3D printing of SlipChip devices, this work will enhance the ability to rapidly prototype such devices at mid-scale levels of production

    Harmonic dependence of thermal magnetic particle imaging

    No full text
    Abstract Advances in instrumentation and tracer materials are still required to enable sensitive, accurate, and localized in situ 3D temperature monitoring by magnetic particle imaging (MPI). We have developed a high-resolution magnetic particle imaging instrument and implemented a low-noise multi-harmonic lock-in detection method to observe and quantify temperature variations in iron oxide nanoparticle tracers using the harmonic ratio method for determining temperature. Using isolated harmonics for MPI and temperature imaging revealed an apparent dependence of imaging resolution on harmonic number. Thus, we present experimental and simulation studies to quantify the imaging resolution dependence on temperature and harmonic number, and directly validate the fundamental origin of MPI imaging resolution on harmonic number based on the concept of a harmonic point-spread-function
    corecore