2 research outputs found

    Massage Gun Use at a Lower Frequency Does Not Alter Blood Flow

    Get PDF
    Data has shown that whole body vibration can affect blood flow velocity in arteries and improves cutaneous blood flow. However, there is very limited information available on therapeutic localized vibration. Massage guns have become very popular with little to no research validating their efficacy. It is currently unknown if massages guns can affect arterial blood flow. PURPOSE: To determine if massage gun treatment at 30Hz improves and retains blood flow in the popliteal artery as compared to a control condition. METHODS: There were 12 participants in this study (8 males and 4 females). The mean age was 22.7±1.6 yrs, the mean height was 181.1± 11.8 cm, and the mean weight was 78.2±16.2 kg. Participants wore shorts that allowed us to access their popliteal artery using ultrasound imaging. Participants wore electrodes to control the measurement of blood flow from widest artery diameter. Participants lay prone with a foam roller under their ankles to slightly elevate their feet. After ten minutes of rest, ultrasound imaging was used to find the participant’s popliteal artery behind the knee and took two baseline measurements. We measured the mean velocity of blood flow (TAmean) and volume flow (VolF). We measured subjects on 4 different days (30Hz at 5 minutes, 30Hz 10 minutes, Control 5 minutes, Control 10 minutes). Measurements of TAmean and VolF were measured at multiple time points after treatment. RESULTS: A two-factor repeated measures analysis was performed. Each subject was measured under all levels of condition (1=30hz 5 min, 4=Control 5 mi, 5=30hz 10 min, 8=Control 10 min) and time (baseline, post, post1-5, 7, 9, 11, 13, 15, 17, 19). TA mean is significantly greater in 30Hz versus control (p=0.0349). TAmean varies across time, and the effect of the condition on TAmean is related to time (p=0.0104). There is not a significant difference in flow between 30Hz and control (p=0.2425). Blood flow varies across time (pCONCLUSION: Use of a massage gun at a lower frequency setting of 30Hz may cause slight increases in velocity but does not increase mean blood flow as compared to control. Lower frequency settings on massage guns may not be benefit blood flow in the massaged muscle group

    Effect of Localized Vibration Using Massage Gun at 40hz and 50hz on Blood Flow

    Get PDF
    Data has shown that whole body vibration can positively affect blood flow, however, there are very few studies on the effect of localized therapeutic vibration on arterial blood flow. Occupational studies looking at localized vibration effects on skin blood flow normally include high frequency settings. In the last few years, massage guns have become popular, but they operate at lower frequencies. Currently, there is no data on the effects of localized vibration from massage guns on arterial blood flow. PURPOSE: To compare the effects of two different frequencies of localized vibration on blood flow in the popliteal artery. METHODS: 12 subjects participated in this study (8 males and 4 females). Mean age was 22.7±1.6 years; mean height was 181.1±11.8 cm; mean weight was 78.2±16.2 kg. Participants wore shorts to give access to the popliteal artery. Participants were hooked to ECG leads to control measurement of artery diameter and then laid on a treatment table in a prone position with a foam roller under their ankles. Once at resting heart rate, baseline blood flow readings were taken using ultrasound, which measured TA Mean and Volume Flow. The participants were then randomly given a 5-minute treatment of control with no vibration or vibration at 40hz or 50hz. Blood flow readings were taken immediately post-treatment and then every minute for 5 minutes after. RESULTS: A two-factor repeated measures analysis was performed. Each subject was measured under all levels of condition (Control 5 min, 40hz 5 min, and 50hz 5 min) and time (baseline, post, post1-5). TA Mean and Volume Flow for both 40hz and 50hz were significantly greater than control (p=0.0020 and p=0.0110 respectively). The effect of time was significant (
    corecore