58 research outputs found

    An in vitro study comparing a peripherally inserted central catheter to a conventional central venous catheter: no difference in static and dynamic pressure transmission

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Early goal directed therapy improves survival in patients with septic shock. Central venous pressure (CVP) monitoring is essential to guide adequate resuscitation. Use of peripherally inserted central catheters (PICC) is increasing, but little data exists comparing a PICC to a conventional CVP catheter. We studied the accuracy of a novel PICC to transmit static and dynamic pressures <it>in vitro</it>.</p> <p>Methods</p> <p>We designed a device to generate controlled pressures via a column of water allowing simultaneous measurements from a PICC and a standard triple lumen catheter. Digital transducers were used to obtain all pressure readings. Measurements of static pressures over a physiologic range were recorded using 5Fr and 6Fr dual lumen PICCs. Additionally, random repetitive pressure pulses were applied to the column of water to simulate physiologic intravascular pressure variations. The resultant PICC and control waveforms were recorded simultaneously.</p> <p>Results</p> <p>Six-hundred thirty measurements were made using the 5 Fr and 6 Fr PICCs. The average bias determined by Bland-Altman plot was 0.043 mmHg for 5 Fr PICC and 0.023 mmHg for 6 Fr PICC with a difference range of 1.0 to -1.0. The correlation coefficient for both catheters was 1.0 (p-value < 0.001). Dynamic pressure waveforms plotted simultaneously between PICC and control revealed equal peaks and troughs.</p> <p>Conclusion</p> <p><it>In vitro</it>, no static or dynamic pressure differences were found between the PICC and a conventional CVP catheter. Clinical studies are required to assess whether the novel PICC has bedside equivalence to conventional catheters when measuring central venous pressures.</p

    Transanal total mesorectal excision: a pure NOTES approach for selected patients

    Get PDF
    Background: The concept of natural orifice transluminal endoscopic surgery (NOTES) has stimulated the development of various “incisionless” procedures. One of the most popular is the transanal approach for rectal lesions. The aims of this study were to report how we standardized NOTES technique for transanal mesorectal excision without abdominal assistance, discuss the difficulties and surgical outcomes of this technique and report its feasibility in a small group of selected patients. Methods: Three consecutive female patients underwent transanal NOTES rectal resection without transabdominal laparoscopic assistance for rectal lesions. Functional results were assessed with the Fecal Incontinence Quality of Life scale and the Wexner score. Results: The technical steps are described in details and complemented with a video. All procedures were completed without transabdominal laparoscopic help. The mesorectal plane was entirely dissected without any disruption, and distal and circumferential margins were tumor-free. No major complications were observed. Functional results show a significant impairment after surgery with improvement at 6 months to levels near those of the preoperative period. Conclusions: The performance and publication of NOTES procedures are subject to much discussion. Despite the small number of patients, this procedure appears feasible and can be accomplished maintaining fecal continence and respecting oncologic principles

    Repair of Parastomal Hernias with Biologic Grafts: A Systematic Review

    Get PDF
    Contains fulltext : 98303.pdf (publisher's version ) (Open Access)BACKGROUND: Biologic grafts are increasingly used instead of synthetic mesh for parastomal hernia repair due to concerns of synthetic mesh-related complications. This systematic review was designed to evaluate the use of these collagen-based scaffolds for the repair of parastomal hernias. METHODS: Studies were retrieved after searching the electronic databases MEDLINE, EMBASE and Cochrane CENTRAL. The search terms 'paracolostomy', 'paraileostomy', 'parastomal', 'colostomy', 'ileostomy', 'hernia', 'defect', 'closure', 'repair' and 'reconstruction' were used. Selection of studies and assessment of methodological quality were performed with a modified MINORS index. All reports on repair of parastomal hernias using a collagen-based biologic scaffold to reinforce or bridge the defect were included. Outcomes were recurrence rate, mortality and morbidity. RESULTS: Four retrospective studies with a combined enrolment of 57 patients were included. Recurrence occurred in 15.7% (95% confidence interval [CI] 7.8-25.9) of patients and wound-related complications in 26.2% (95% CI 14.7-39.5). No mortality or graft infections were reported. CONCLUSIONS: The use of reinforcing or bridging biologic grafts during parastomal hernia repair results in acceptable rates of recurrence and complications. However, given the similar rates of recurrence and complications achieved using synthetic mesh in this scenario, the evidence does not support use of biologic grafts

    Prevalence of high-risk human papillomavirus types in Mexican women with cervical intraepithelial neoplasia and invasive carcinoma

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Prevalence of high risk (HR) human papillomavirus (HPV) types in the states of San Luis PotosĂ­ (SLP) and Guanajuato (Gto), Mexico, was determined by restriction fragment length-polymorphism (RFLP) analysis on the E6 ~250 bp (E6-250) HR-HPV products amplified from cervical scrapings of 442 women with cervical intraepithelial neoplasia and invasive carcinoma (280 from SLP and 192 from Gto). Fresh cervical scrapings for HPV detection and typing were obtained from all of them and cytological and/or histological diagnoses were performed on 383.</p> <p>Results</p> <p>Low grade intraepithelial squamous lesions (LSIL) were diagnosed in 280 cases (73.1%), high grade intraepithelial squamous lesions (HSIL) in 64 cases (16.7%) and invasive carcinoma in 39 cases (10.2%). In the 437 cervical scrapings containing amplifiable DNA, only four (0.9%) were not infected by HPV, whereas 402 (92.0%) were infected HR-HPV and 31 (7.1%) by low-risk HPV. RFLP analysis of the amplifiable samples identified infections by one HR-HPV type in 71.4%, by two types in 25.9% and by three types in 2.7%. The overall prevalence of HR-HPV types was, in descending order: 16 (53.4%) > 31 (15.6%) > 18 (8.9%) > 35 (5.6) > 52 (5.4%) > 33 (1.2%) > 58 (0.7%) = unidentified types (0.7%); in double infections (type 58 absent in Gto) it was 16 (88.5%) > 31 (57.7%) > 35 (19.2%) > 18 (16.3%) = 52 (16.3%) > 33 (2.8%) = 58 (2.8%) > unidentified types (1.0%); in triple infections (types 33 and 58 absent in both states) it was 16 (100.0%) > 35 (54.5%) > 31 (45.5%) = 52 (45.5%) > 18 (27.3%). Overall frequency of cervical lesions was LSIL (73.1%) > HSIL (16.7%) > invasive cancer (10.2%). The ratio of single to multiple infections was inversely proportional to the severity of the lesions: 2.46 for LSIL, 2.37 for HSIL and 2.15 for invasive cancer. The frequency of HR-HPV types in HSIL and invasive cancer lesions was 16 (55.0%) > 31 (18.6%) > 35 (7.9%) > 52 (7.1%) > 18 (4.3%) > unidentified types (3.6%) > 33 (2.9%) > 58 (0.7%).</p> <p>Conclusion</p> <p>Ninety percent of the women included in this study were infected by HR-HPV, with a prevalence 1.14 higher in Gto. All seven HR-HPV types identifiable with the PCR-RFLP method used circulate in SLP and Gto, and were diagnosed in 99.3% of the cases. Seventy-one percent of HR-HPV infections were due to a single type, 25.9% were double and 2.7% were triple. Overall frequency of lesions was LSIL (73.1%) > HSIL (16.7%) > invasive cancer (10.2%), and the ratio of single to multiple infections was inversely proportional to severity of the lesions: 2.46 for LSIL, 2.37 for HSIL and 2.15 for invasive cancer. The frequency of HR-HPV types found in HSIL and invasive cancer was 16 (55.0%) > 31 (18.6%) > 35 (7.9%) > 52 (7.1%) > 18 (4.3%) > unidentified types (3.6%) > 33 (2.9%) > 58 (0.7%). Since the three predominant types (16, 31 and 18) cause 77.9% of the HR-HPV infections and immunization against type 16 prevents type 31 infections, in this region the efficacy of the prophylactic vaccine against types 16 and 18 would be close to 80%.</p

    A new automated method for the determination of the Total Antioxidant Capacity (TAC) of human plasma, based on the crocin bleaching assay

    Get PDF
    BACKGROUND: Antioxidant molecules, which scavenge free radical species to prevent or delay oxidative damage of important macromolecules, membrane lipids and lipoproteins, are prevalent in plasma and other biological fluids. Among them, bilirubin, uric acid and protein thiols are the major endogenous antioxidants, while vitamins C and E, as well as a number of food-derived (poly)aromatic substances, belonging to stilbens, flavonoids and phenolic acids, are the main classes of nutritional antioxidants. Assays for total antioxidant capacity in plasma differ in their type of oxidation source, target and measurement used to detect the oxidized product. METHODS: In the present work we present an automated assay for the estimation of blood total antioxidant capacity (TAC assay), based on the crocin bleaching (oxidation) method. This method was adapted on a modern autoanalyzer, was linear over a wide range of values (0–3 mmol/L), and performed using an end point measurement. RESULTS: The TAC method presented a linear correlation with another automated commercial Total Antioxidant Status (TAS) test. Detection of the interference of different metabolites revealed a significant participation of TAC from uric acid, bilirubin, albumin, a minor interference from ascorbic acid, and no interference from hemoglobin. TAC was not modified by two freeze/thawing cycles, and was stable in samples stored at room temperature for 4 hours. K-EDTA and heparin were the best anticoagulants, while citrate decreased TAC by 20%. Reference values derived from samples of normal blood donors was 1.175 ± 0.007 mmol/L (mean ± SEM), while a diet rich in antioxidants more than doubled this value. CONCLUSIONS: The proposed TAC assay, is fully automated, stable and reliable, and could be of value in the estimation of the AC of plasma. It is further proposed to calculate the antioxidant capacity of plasma after a subtraction of all interference deriving from endogenous and/or exogenous metabolites. The antioxidant capacity of plasma thus calculated can be used as a useful indicator of the antioxidant value of foods and beverages in the daily diet
    • …
    corecore