Pupillary unrest, opioid intensity, and the impact of environmental stimulation on respiratory depression.
Pupillary unrest, opioid intensity, and the impact of environmental stimulation on respiratory depression.
Opioid-induced respiratory depression (OIRD) confers significant morbidity, but its onset can be challenging to recognize. Pain or stimulation effects of conversation may mask or attenuate common clinical manifestations of OIRD. We asked whether pupillary unrest could provide an objective signal of opioid exposure, and whether this signal would be independent from the confounding influence of extrinsic stimulation. We conducted a cross-over trial of healthy volunteers using identical remifentanil infusions separated by a washout period; in both, pupillary unrest in ambient light (PUAL) was measured at 2.5-min intervals. During one infusion, investigators continuously engaged the subject in conversation, while in the other, a quiet environment was maintained; measures of respiratory depression were compared under each condition. We tested PUAL's relationship to estimated opioid concentration under quiet conditions, measured PUAL's discrimination of lower versus higher opioid exposure using receiver operating characteristic (ROC) analysis, and assessed the effect of stimulation on PUAL versus opioid using mixed effects regression. Respiratory depression occurred more frequently under quiet conditions (p < 0.0001). Under both conditions, PUAL declined significantly over the course of the remifentanil infusion and rose during recovery (p < 0.0001). PUAL showed excellent discrimination in distinguishing higher versus absent-moderate opioid exposure (AUROC = 0.957 [0.929 to 0.985]), but was unaffected by interactive versus quiet conditions (mean difference, interactive - quiet = - 0.007, 95% CI - 0.016 to 0.002). PUAL is a consistent indicator of opioid effect, and distinguishes higher opioid concentrations independently of the stimulating effects of conversational interaction. Under equivalent opioid exposure, conversational interaction delayed the onset and minimized the severity of OIRD.Clinical trial registration: NCT04301895
Recommended from our members
Evaluation of two portable pupillometers to assess clinical utility.
BackgroundPupillometers have been proposed as clinical assessment tools. We compared two pupillometers to assess measurement agreement.Materials & methodsWe enrolled 30 subjects and simultaneously measured the pupil diameter and light reflex amplitude with an iPhone pupillometer and a portable infrared pupillometer. We then enrolled 40 additional subjects and made serial measurements with each device.ResultsFailure occurred in 30% of attempts made with the iPhone pupillometer compared with 4% of attempts made with the infrared pupillometer (Fisher's exact p = 0.0001). Method comparison of the two devices used simultaneously showed significant disagreement in dynamic measurements.ConclusionThe iPhone pupillometer had poor repeatability and suggests that it is not a practical tool to support clinical decisions