30 research outputs found

    The perfect crime? : CCSVI not leaving a trace in MS

    Get PDF
    Background: Multiple sclerosis (MS) is a chronic, inflammatory demyelinating disease of the central nervous system, believed to be triggered by an autoimmune reaction to myelin. Recently, a fundamentally different pathomechanism termed ‘chronic cerebrospinal venous insufficiency’ (CCSVI) was proposed, provoking significant attention in the media and scientific community. Methods: Twenty MS patients (mean age 42.2±13.3 years; median Extended Disability Status Scale 3.0, range 0–6.5) were compared with 20 healthy controls. Extra- and intracranial venous flow direction was assessed by colour-coded duplex sonography, and extracranial venous cross-sectional area (VCSA) of the internal jugular and vertebral veins (IJV/VV) was measured in B-mode to assess the five previously proposed CCSVI criteria. IJV-VCSA≤0.3 cm2 indicated ‘stenosis,’ and IJV-VCSA decrease from supine to upright position ‘reverted postural control.’ The sonographer, data analyser and statistician were blinded to the patient/control status of the participants. Results: No participant showed retrograde flow of cervical or intracranial veins. IJV-VCSA≤0.3 cm2 was found in 13 MS patients versus 16 controls (p=0.48). A decrease in IJV-VCSA from supine to upright position was observed in all participants, but this denotes a physiological finding. No MS patient and one control had undetectable IJV flow despite deep inspiration (p=0.49). Only one healthy control and no MS patients fulfilled at least two criteria for CCSVI. Conclusions: This triple-blinded extra- and transcranial duplex sonographic assessment of cervical and cerebral veins does not provide supportive evidence for the presence of CCSVI in MS patients. The findings cast serious doubt on the concept of CCSVI in MS

    Cerebral Hemodynamic Failure Presenting as Limb-Shaking Transient Ischemic Attacks

    Get PDF
    Limb-shaking transient ischemic attacks (TIA) may occur in patients with insufficient brain perfusion due to an underlying occlusive disease. We present the case of a 64-year-old patient who suffered from repetitive TIA presenting with shaking movements of the right-sided extremities and accompanying speech arrest. Symptoms are documented in the online supplementary video (www.karger.com/doi/10.1159/000327683). These episodes were frequently triggered in orthostatic situations. The diagnosis of limb-shaking TIA was established. The diagnostic workup revealed pseudo-occlusion of the left internal carotid artery, a poor intracranial collateral status and, as a consequence, an exhausted vasomotor reserve capacity. At ultrasound examination, symptoms were provoked by a change of the patient's position from supine to sitting. During evolvement of symptoms, a dramatic decrease of flow velocities in the left middle cerebral artery was observed. This case thus documents the magnitude and dynamics of perfusion failure in a rare manifestation of cerebral ischemic disease

    Decrease in shunt volume in patients with cryptogenic stroke and patent foramen ovale

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>In patients with patent foramen ovale (PFO) there is evidence supporting the hypothesis of a change in right-to-left shunt (RLS) over time. Proven, this could have implications for the care of patients with PFO and a history of stroke. The following study addressed this hypothesis in a cohort of patients with stroke and PFO.</p> <p>Methods</p> <p>The RLS volume assessed during hospitalisation for stroke (index event/T0) was compared with the RLS volume on follow-up (T1) (median time between T0 and T1 was 10 months). In 102 patients with a history of stroke and PFO the RLS volume was re-assessed on follow-up using contrast-enhanced transcranial Doppler/duplex (ce-TCD) ultrasound. A change in RLS volume was defined as a difference of ≥20 microembolic signals (MES) or no evidence of RLS during ce-TCD ultrasound on follow-up.</p> <p>Results</p> <p>There was evidence of a marked reduction in RLS volume in 31/102 patients; in 14/31 patients a PFO was no longer detectable. An index event classified as cryptogenic stroke (P < 0.001; OD = 39.2, 95% confidence interval 6.0 to 258.2) and the time interval to the follow-up visit (P = 0.03) were independently associated with a change in RLS volume over time.</p> <p>Conclusions</p> <p>RLS volume across a PFO decreases over time, especially in patients with cryptogenic stroke. These may determine the development of new strategies for the management in the secondary stroke prevention.</p

    Blood-Brain Barrier Disruption by Low-Frequency Ultrasound

    No full text

    Active regulation of cerebral venous tone: simultaneous arterial and venous transcranial Doppler sonography during a Valsalva manoeuvre

    No full text
    The aim of this study was to analyse the cerebral venous outflow in relation to the arterial inflow during a Valsalva manoeuvre (VM). In 19 healthy volunteers (mean age 24.1 +/- 2.6 years), the middle cerebral artery (MCA) and the straight sinus (SRS) were insonated by transcranial Doppler sonography. Simultaneously the arterial blood pressure was recorded using a photoplethysmographic method. Two VM of 10 s length were performed per participant. Tracings of the variables were then transformed to equidistantly re-sampled data. Phases of the VM were analysed regarding the increase of the flow velocities and the latency to the peak. The typical four phases of the VM were also found in the SRS signal. The relative flow velocity (FV) increase was significantly higher in the SRS than in the MCA for all phases, particularly that of phase IV (p < 0.01). Comparison of the time latency of the VM phases of the MCA and SRS only showed a significant difference for phase I (p < 0.01). In particular, there was no significant difference for phase IV (15.8 +/- 0.29 vs. 16.0 +/- 0.28 s). Alterations in venous outflow in phase I are best explained by a cross-sectional change of the lumen of the SRS, while phases II and III are compatible with a Starling resistor. However, the significantly lager venous than the arterial overshoot in phase IV may be explained by the active regulation of the venous tone

    Platelet rich clots are resistant to lysis by thrombolytic therapy in a rat model of embolic stroke

    Get PDF
    Background: Early recanalization of occluded vessels in stroke is closely associated with improved clinical outcome. Microbubble-enhanced sonothrombolysis is a promising therapy to improve recanalization rates and reduce the time to recanalization. Testing any thrombolytic therapy requires a model of thromboembolic stroke, but to date these models have been highly variable with regards to clot stability. Here, we developed a model of thromboembolic stroke in rats with site-specific delivery of platelet-rich clots (PRC) to the main stem of the middle cerebral artery (MCA). This model was used in a subsequent study to test microbubble-enhanced sonothrombolysis. Methods: In Study 1 we investigated spontaneous recanalization rates of PRC in vivo over 4 hours and measured infarct volumes at 24 hours. In Study 2 we investigated tPA-mediated thrombolysis and microbubble-enhanced sonothrombolysis in this model. Results: Study 1 demonstrated stable occlusion out to 4 hours in 5 of 7 rats. Two rats spontaneously recanalized at 40 and 70 minutes post-embolism. Infarct volumes were not significantly different in recanalized rats, 43.93 ± 15.44% of the ischemic hemisphere, compared to 48.93 ± 3.9% in non-recanalized animals (p = 0.7). In Study 2, recanalization was not observed in any of the groups post-treatment. Conclusions: Site specific delivery of platelet rich clots to the MCA origin resulted in high rates of MCA occlusion, low rates of spontaneous clot lysis and large infarction. These platelet rich clots were highly resistant to tPA with or without microbubble-enhanced sonothrombolysis. This resistance of platelet rich clots to enhanced thrombolysis may explain recanalization failures clinically and should be an impetus to better clot-type identification and alternative recanalization methods

    Sonografisches Neuromonitoring auf der Stroke Unit und in der neurologischen Intensivmedizin

    No full text
    Background To give an up-to-date overview of neurosonographic diagnostics in intensive care medicine. Methods Selective literature research with critical appraisal from 1984 on including national and international guidelines, and expert opinion. Results Fast and valid diagnostics in acute stroke is the main field of application of neurosonography. Specific sonographic monitoring methods bear great advantages for intensive care patients, especially "as-often-as-wanted" repetitive imaging under real-time conditions. A number of new developments make neurosonography an interesting area of research. Conclusion Neurosonography has a key role in neurologic intensive care medicine since many years. It remains important to continuously spread the methods further and strengthen its validity by scientific evidence

    Establishment of an Arbitrary PCR for Rapid Identification of Tn917 Insertion Sites in Staphylococcus epidermidis: Characterization of Biofilm-Negative and Nonmucoid Mutants

    No full text
    Transposon mutagenesis with the Enterococcus faecalis transposon Tn917 is a genetic approach frequently used to identify genes related with specific phenotypes in gram-positive bacteria. We established an arbitrary PCR for the rapid and easy identification of Tn917 insertion sites in Staphylococcus epidermidis with six independent, well-characterized biofilm-negative Tn917 transposon mutants, which were clustered in the icaADBC gene locus or harbor Tn917 in the regulatory gene rsbU. For all six of these mutants, short chromosomal DNA fragments flanking both transposon ends could be amplified. All fragments were sufficient to correctly identify the Tn917 insertion sites in the published S. epidermidis genomes. By using this technique, the Tn917 insertion sites of three not-yet-characterized biofilm-negative or nonmucoid mutants were identified. In the biofilm-negative and nonmucoid mutant M12, Tn917 is inserted into a gene homologous to the regulatory gene purR of Bacillus subtilis and Staphylococcus aureus. The Tn917 insertions of the nonmucoid but biofilm-positive mutants M16 and M20 are located in genes homologous to components of the phosphoenolpyruvate-sugar phosphotransferase system (PTS) of B. subtilis, S. aureus, and Staphylococcus carnosus, indicating an influence of the PTS on the mucoid phenotype in S. epidermidis
    corecore