65 research outputs found

    Reply

    Get PDF

    Improvement in accuracy of diagnosis of carotid artery stenosis with duplex ultrasound scanning with combined use of linear array 7.5 MHz and convex array 3.5 MHz probes: validation versus 489 arteriographic procedures1 1Competition of interest: none.Published online Mar 6, 2003.

    Get PDF
    AbstractObjective: Validity of a method to improve the accuracy of carotid artery duplex scanning was tested in comparison with arteriography.Study Design: In 489 patients who had not previously undergone arteriography, 978 carotid arteries were examined with duplex ultrasound scanning. In method A, a linear array 7.5 MHz transducer with pulsed-wave 4.7 MHz Doppler scanning was used. For the diagnosis and grading of carotid stenosis, peak systolic and end-diastolic velocity of the Doppler waves were recorded. Method B consisted of complete ultrasound imaging and color-flow mapping with a convex array 3.5 MHz transducer with pulsed-wave 2.8 MHz Doppler scanning in all patients who had previously undergone method A. Further velocity measurements were performed at the sites of stenosis. The results of methods A and B were compared with data from neurologic assessment and arteriographic studies.Results: Method B showed significantly higher diagnostic agreement with arteriography than did method A (K 95% confidence interval [CI], 0.87–0.93 vs 0.79–0.85; P < .05), and the number of mistakes in grading stenosis was significantly lower (primarily because of decreased overestimation) in patients with internal carotid kinking (>60 degrees of angulation) (P < .05), distal stenosis (>20 mm from bifurcation) (P < .01), or wide acoustic shadowing (>1 cm) (P < .01) and in those without these conditions (P < .05). Compared with arteriography, diagnostic accuracy with the new method proved higher for carotid stenoses 50% or greater, 60% or greater, 70% or greater, and 80% or greater; no statistically significant difference was found for carotid stenosis 96% or greater or for carotid occlusion. Compared with data from neurologic assessment and arteriography, method B proved more accurate than method A in designating patients for carotid endarterectomy (P = .014).Conclusions: The new method significantly improved diagnostic reliability of duplex ultrasound scanning, especially in carotid arteries with kinking, distal stenosis, or wide acoustic shadowing (32.2% of all arteries studied). In clinical practice, we suggest additional use of a lower frequency transducer in cases in which these three conditions are found or suspected at first scanning

    Dose-dependent fetal complications of warfarin in pregnant women with mechanical heart valves

    Get PDF
    AbstractOBJECTIVESThe purpose of this study was to assess the incidence of warfarin fetal complications and whether they are dose-dependent.BACKGROUNDGravid patients with mechanical heart valves require long-term anticoagulant therapy. Controversy exists concerning the appropriate treatment of these patients.METHODSForty-three women on warfarin carrying out 58 pregnancies were studied. For each patient with full-term pregnancy a caesarian section was scheduled for the 38th week during brief warfarin discontinuation. Maternal and fetal complications were evaluated. Fetal complications were divided according to the warfarin dosage ≤5 mg and >5 mg necessary to keep an international normalized ratio (INR) of 2.5 to 3.5, and analyzed subsequently.RESULTSA total of 58 pregnancies were observed: 31 healthy babies (30 full term, 1 premature) and 27 fetal complications (22 spontaneous abortions, 2 warfarin embryopathies, 1 stillbirth, 1 ventricular septal defect, 1 growth retardation) were recorded. Two maternal valve thromboses occurred. No fetal or maternal bleeding was observed during caesarian sections or premature vaginal delivery. Patients whose warfarin doses during pregnancy were >5 mg had 22 fetal complications, whereas those taking a dose ≤5 mg had only five fetal complications (p = 0.0001). For an increase of the warfarin dose there was a substantially increased probability of fetal complications (p < 0.0001; ρ < 0.7316).CONCLUSIONSThere is a close dependency between warfarin dosage and fetal complications. Patients on warfarin anticoagulation may be delivered by planned caesarian section at the 38th week while briefly interrupting anticoagulation

    The Need for a Specific Risk Prediction System in Native Valve Infective Endocarditis Surgery

    Get PDF
    The need for a specific risk score system for infective endocarditis (IE) surgery has been previously claimed. In a single-center pilot study, preliminary to future multicentric development and validation, bivariate and multivariate (logistic regression) analysis of early postoperative mortality predictors in 440 native valve IE patients were performed. Mathematical procedures assigned scores to the independent predictors emerged (AUC of the ROC curve: 0.88). Overall mortality was 9.1%. Six predictors were identified and assigned scores, including age (5–13 points), renal failure (5), NYHA class IV (9), critical preoperative state (11), lack of preoperative attainment of blood culture negativity (5), perivalvular involvement (5). Four risk classes were drawn ranging from “very low risk” (≤5 points, mean predicted mortality 1%), and to “very high risk” (≥20 points, 43% mortality). IE-specific risk stratification models are both needed, as disease-specific factors (e.g., cultures, abscess), beside the generic ones (e.g., age, renal impairment) affect mortality, and feasible

    Efficacy and Safety of Low-Dose Cyclosporine with Everolimus and Steroids in de novo Heart Transplant Patients: A Multicentre, Randomized Trial

    Get PDF
    A six-month, multicenter, randomized, open-label study was undertaken to determine whether renal function is improved using reduced-exposure cyclosporine (CsA) versus standard-exposure CsA in 199 de novo heart transplant patients receiving everolimus and steroids ± induction therapy. Mean C2 levels were at the low end of the target range in standard-exposure patients (n = 100) and exceeded target range in reduced-exposure patients (n = 99) throughout the study. Mean serum creatinine at Month 6 (the primary endpoint) was 141.0 ± 53.1 μmol/L in standard-exposure patients versus 130.1 ± 53.7 μmol/L in reduced-exposure patients (P = 0.093). The incidence of biopsy-proven acute rejection ≥3A at Month 6 was 21.0% (21/100) in the standard-exposure group and 16.2% (16/99) in the reduced-exposure group (n.s.). Adverse events and infections were similar between treatment groups. Thus, everolimus with reduced-exposure CsA resulted in comparable efficacy compared to standard-exposure CsA. No renal function benefits were demonstrated; that is possibly related to poor adherence to reduced CsA exposure

    Mitral and Aortic Valve Endocarditis Due to Staphylococcus lugdunensis

    No full text
    Staphylococcus lugdunensis is a recently described coagulase negative staphylococcal species involved in human infections. Endocarditis caused by Staphylococcus lugdunensis has been reported rarely: fewer than 50 cases have been described so far. The infection is frequently complicated by embolic events and carries a high mortality rate. We report a case of endocarditis due to Staphylococcus lugdunensis in which the native mitral and aortic valves were infected. The bacterium was isolated on cultures from the aortic and mitral vegetations. Appropriate medical and surgical treatment led to a good outcome of the infection. At 6-year follow-up, there was no evidence of recurrence, and the patient showed good functional recovery. He was in New York Heart Association functional class I

    Coronary artery bypass grafting associated to aortic valve replacement in the elderly: survival and quality of life

    No full text
    Abstract Myocardial ischemia is often associated to aortic valve stenosis in the elderly. Aim of this study was to evaluate the impact on survival and quality of life of CABG associated to aortic valve replacement in the septuagenarians and octogenarians. Between January 1991 and January 2010, 520 patients ageing > 70 years underwent aortic valve replacement with a mechanical prosthesis in two Institutions. They were divided into 2 groups: Group A included 406 patients undergoing isolated aortic valve replacement; Group B 114 patients receiving aortic valve replacement and CABG. A comparative analysis of long-term survival and quality of life (SF-36 test) was performed. Mean age was 74.2 ± 3.6 years (74.3 ± 3.6 in Group A, 74 ± 3.3 in Group B; p = 0.33). Hospital mortality was 9.5% (46 patients). Twenty-nine (7.8%) in Group A and 17 in Group B (15.2%)(p = 0.019). Actuarial survival was 88.5% ± 0.015 at 1 year, 81.9% ± 0.02 at 5 years, 76.6% ± 0.032 at 10 and 57.3 ± 0.1 at 15 years. Ten-year survival was 77% ± 0.034 in Group A and 77.8% ± 0.045 in Group B (p = 0.2). Multivariate analysis did not reveal associated CABG as a predictor of long term mortality. The scores obtained in the SF-36 test were similar in the two groups and significantly higher than those of the general population matched for country, age and sex (p Associated CABG determines a significant increase of hospital mortality in the elderly undergoing aortic valve replacement. Survivors did not show differences in long-term outcome and quality of life according to the presence of associated CABG.</p

    Letter

    No full text
    corecore