    Proficiency testing for HIV, tuberculosis and malaria diagnosis in clinical laboratories in Nigeria

    No full text
    Background: Proficiency testing (PT) is a means of verifying the reliability of laboratory results, but such programmes are not readily available to laboratories in developing countries. This project provided PT to laboratories in Nigeria. Objectives: To assess the proficiency of laboratories in the diagnosis of HIV, tuberculosis and malaria. Methods: This was a prospective study carried out between 2009 and 2011. A structured questionnaire was administered to 106 randomly-selected laboratories. Forty-four indicated their interest in participation and were enrolled. Four rounds of pre-characterised plasma panels for HIV, sputum films for tuberculosis and blood films for malaria were distributed quarterly by courier over the course of one year. The results were returned within two weeks and scores of ≥ 80% were reported as satisfactory. Mentoring was offered after the first and second PT rounds. Results: Average HIV PT scores increased from 74% to 95% from the first round to the third round, but decreased in the fourth round. For diagnosis of tuberculosis, average scores increased from 42% in the first round to 78% in the second round; but a decrease to 34% was observed in the fourth round. Malaria PT performance was 2% at first, but average scores increased between the second and fourth rounds, culminating in a fourth-round score of 39%. Many participants requested training and mentoring. Conclusions: There were gross deficiencies in the quality of laboratory services rendered across Nigeria. In-country PT programmes, implemented in conjunction with mentoring, will improve coverage and diagnosis of HIV, tuberculosis and malaria

    Experience of quality management system in a clinical laboratory in Nigeria

    No full text
    Issues: Quality-management systems (QMS) are uncommon in clinical laboratories in Nigeria, and until recently, none of the nation’s 5 349 clinical laboratories have been able to attain the certifications necessary to begin the process of attaining international accreditation. Nigeria’s Human Virology Laboratory (HVL), however, began implementation of a QMS in 2006, and in 2008 it was determined that the laboratory conformed to the requirements of ISO 9001:2000 (now 2008), making it the first diagnostic laboratory to be certified in Nigeria. The HVL has now applied for the World Health Organization (WHO) accreditation preparedness scheme. The experience of the QMS implementation process and the lessons learned therein are shared here. Description: In 2005, two personnel from the HVL spent time studying quality systems in a certified clinical laboratory in Dakar, Senegal. Following this peer-to-peer technical assistance, several training sessions were undertaken by HVL staff, a baseline assessment was conducted, and processes were established. The HVL has monitored its quality indicators and conducted internal and external audits; these analyses (from 2007 to 2009) are presented herein. Lessons learned: Although there was improvement in the pre-analytical and analytical indicators analysed and although data-entry errors decreased in the post-analytical process, the delay in returning laboratory test results increased significantly. There were several factors identified as causes for this delay and all of these have now been addressed except for an identified need for automation of some high-volume assays (currently being negotiated). Internal and external audits showed a trend of increasing non-conformities which could be the result of personnel simply becoming lax over time. Application for laboratory accreditation, however, could provide the renewed vigour needed to correct these non-conformities. Recommendation: This experience shows that sustainability of the QMS at present is a cause for concern. However, the tiered system of accreditation being developed by WHO–Afro may act as a driving force to preserve the spirit of continual improvement

    Comparison of one single-antigen assay and three multi-antigen SARS-CoV-2 IgG assays in Nigeria

    No full text
    Objectives: Determining an accurate estimate of SARS-CoV-2 seroprevalence has been challenging in African countries where malaria and other pathogens are endemic. We compared the performance of one single-antigen assay and three multi-antigen SARS-CoV-2 IgG assays in a Nigerian population endemic for malaria. Methods: De-identified plasma specimens from SARS-CoV-2 RT-PCR positive, dried blood spot (DBS) SARS-CoV-2 RT-PCR positive, and pre-pandemic negatives were used to evaluate the performance of the four SARS-CoV-2 assays (Tetracore, SARS2MBA, RightSign, xMAP). Results: Results showed higher sensitivity with the multi-antigen (81% (Tetracore), 96% (SARS2MBA), 85% (xMAP)) versus the single-antigen (RightSign (64%)) SARS-CoV-2 assay. The overall specificities were 98% (Tetracore), 100% (SARS2MBA and RightSign), and 99% (xMAP). When stratified based on <15 days to ≥15 days post-RT-PCR confirmation, the sensitivities increased from 75% to 88.2% for Tetracore; from 93% to 100% for the SARS2MBA; from 58% to 73% for RightSign; and from 83% to 88% for xMAP. With DBS, there was no positive increase after 15-28 days for the three assays (Tetracore, SARS2MBA, and xMAP). Conclusion: Multi-antigen assays performed well in Nigeria, even with samples with known malaria reactivity, and might provide more accurate measures of COVID-19 seroprevalence and vaccine efficacy
    corecore