    Hybrid transcatheter left ventricular reconstruction for the treatment of ischemic cardiomyopathy

    Get PDF
    Left ventricular (LV) enlargement is a mechanical adaptation to accommodate LV systolic inefficiency following an acute damage or a progressive functional deterioration, which fails to correct the decline of stroke volume in the long term, leading to progressive heart failure (HF). Surgical ventricular reconstruction (SVR) is a treatment for patients with severe ischemic HF aiming to restore LV efficiency by volume reduction and LV re-shaping. Recently, a new minimally-invasive hybrid technique for ventricular reconstruction has been developed by means of the Revivent (TM) system (BioVentrix Inc., San Ramon, CA, USA). The device for ventricular reconstruction consists of anchor pairs that enable plication of the anterior and free wall LV scar against the right ventricular (RV) septal scar of anteroseptal infarctions to decrease cardiac volume without ventriculotomy in a beating-heart minimally-invasive procedure, consisting of a transjugular and left thoracotomy approach. Patients with severe (Grade 4) functional mitral regurgitation (FMR) or with previous cardiac surgery procedures were excluded. Outcome of the reconstruction procedure: from 2012 until 2019, it has been applied to 203 patients, with 5 (2.5%) in-hospital deaths. LV volume reduction varied according to experience gained along years: LV end-systolic volume index decreased from baseline 43% (post-market registry) vs. 27% (CE-mark study); left ventricular ejection fraction (LVEF) increased from baseline 25% (post-market registry) vs. 16% (CE-mark study). Clinical status (NYHA class, HF questionnaire, 6-minute walking test) improved significantly compared to baseline, and re-hospitalization rate was only 13% at 6-month follow-up (60% of patients in NYHA =3). FMR grade decreased at follow-up in 63%, while it was unchanged in 37% of patients. The hybrid ventricular reconstruction (HVR) seems a promising treatment for HF patients who may benefit from LV volume reduction, with reasonable mortality and good results at follow-up. A baseline less severe clinical profile was not associated to better outcome at follow-up, which makes the procedure feasible in patients with very large ventricles and depressed ejection fraction (EF). LV reshaping has no detrimental effect on FMR, that may, on the contrary, benefit owing to less papillary muscle displacement, partial recovery of torsion dynamics and of myofibers re-orientation. A controlled study on top of optimal medical treatment is warranted to confirm its role in the management of HF patients

    REducing INFectiOns thRough Cardiac device Envelope: insight from real world data. The REINFORCE Project

    Get PDF
    Background: Infections resulting from cardiac implantable electronic device (CIED) implantation are severely impacting on patients' and on health care systems. The use of TYRXTM absorbable antibiotic-eluting envelope has proven to decrease major CIED infections within 12 months of CIED surgery. Aims: to evaluate the impact of the envelope use on infection-related clinical events in a real-world contemporary patient population. Methods: Data on patients undergoing CIED surgery were collected prospectively by participating centers of the One Hospital ClinicalService project. Patients were divided into two groups according to whether TYRXTM absorbable antibiotic-eluting envelope was used or not. Results: Out of 1819 patients, 872 (47.9%) were implanted with an absorbable antibiotic-eluting envelope and included in the Envelope group and 947 (52.1%) patients who did not receive an envelope were included in the Control group. Compared to control, patients in the Envelope group had higher thrombo-embolic or hemorrhagic risk, higher BMI, lower LVEF and more comorbidities. During a mean follow-up of 1.4 years, the incidence of infection-related events was significantly higher in the control compared to the Envelope group (2.4% vs 0.8%, p = 0.007). The 5-year cumulative incidence of infection-related events was 8.1% in the control and 2.1% in the Envelope group (HR: 0.34, 95%CI: 0.14-0.80, p = 0.010). Conclusions: In our analysis, the use of an absorbable antibiotic-eluting envelope in the general CIED population was associated with a lower risk of systemic and pocket infection

    The "Defibrillation Testing, Why Not?" survey. Testing of subcutaneous and transvenous defibrillators in the Italian clinical practice

    Get PDF
    Background: Defibrillation testing (DT) can be omitted in patients undergoing transvenous implantable cardioverter-defibrillator (T-ICD) implantation, but it is still recommended for patients at risk for a high defibrillation threshold and for ICD generator changes. Moreover, DT is still recommended on implantation of subcutaneous ICD (S-ICD). The aim of the present survey was to analyze the current practice of DT during T-ICD and S-ICD implantations.Methods: In March 2021, an ad hoc questionnaire on the current performance of DT and the standard practice adopted during testing was completed at 72 Italian centers implanting S-ICD and T-ICD.Results: 48 (67%) operators reported never performing DT during de-novo T-ICD implantations, while no operators perform it systematically. The remaining respondents perform it for patients at risk for a high defibrillation threshold. DT is never performed at T-ICD generator change. At the time of de-novo S-ICD implantation, DT is never performed by 9 (13%) operators and performed systematically by 48 (66%). The remaining operators frequently omit DT in patients with more severe systolic dysfunction. DT is not performed at S-ICD generator change by 92% of operators. DT is conducted by delivering a first shock energy of 65 J by 60% of operators, while the remaining 40% test lower energy values.Conclusions: In current clinical practice, most operators omit DT at T-ICD implantation, even when still recommended in the guidelines. DT is also frequently omitted at S-ICD implantation, and a wide variability exists among operators in the procedures followed during DT

    Differences in cardiac phenotype and natural history of laminopathies with and without neuromuscular onset

    Get PDF
    Objective: To investigate differences in cardiac manifestations of patients affected by laminopathy, according to the presence or absence of neuromuscular involvement at presentation.Methods: We prospectively analyzed 40 consecutive patients with a diagnosis of laminopathy followed at a single centre between 1998 and 2017. Additionally, reports of clinical evaluations and tests prior to referral at our centre were retrospectively evaluated.Results: Clinical onset was cardiac in 26 cases and neuromuscular in 14. Patients with neuromuscular presentation experienced first symptoms earlier in life (11 vs 39 years; p < 0.0001) and developed atrial fibrillation/flutter (AF) and required pacemaker implantation at a younger age (28 vs 41 years [p = 0.013] and 30 vs 44 years [p = 0.086] respectively), despite a similar overall prevalence of AF (57% vs 65%; p = 0.735) and atrio-ventricular (A-V) block (50% vs 65%; p = 0.500). Those with a neuromuscular presentation developed a cardiomyopathy less frequently (43% vs 73%; p = 0.089) and had a lower rate of sustained ventricular tachyarrhythmias (7% vs 23%; p = 0.387). In patients with neuromuscular onset rhythm disturbances occurred usually before evidence of cardiomyopathy. Despite these differences, the need for heart transplantation and median age at intervention were similar in the two groups (29% vs 23% [p = 0.717] and 43 vs 46 years [p = 0.593] respectively).Conclusions: In patients with laminopathy, the type of disease onset was a marker for a different natural history. Specifically, patients with neuromuscular presentation had an earlier cardiac involvement, characterized by a linear and progressive evolution from rhythm disorders (AF and/or A-V block) to cardiomyopathy

    Acute shock efficacy of the subcutaneous implantable cardioverter-defibrillator according to the implantation technique

    Get PDF
    Background: The traditional technique for subcutaneous implantable cardioverter defibrillator (S-ICD) implantation involves three incisions and a subcutaneous (SC) pocket. An intermuscular (IM) 2-incision technique has been recently adopted. Aims: We assessed acute defibrillation efficacy (DE) of S-ICD (DE ≤65 J) according to the implantation technique. Methods: We analyzed consecutive patients who underwent S-ICD implantation and DE testing at 53 Italian centers. Regression analysis was used to determine the association between DFT and implantation technique. Results: A total of 805 patients were enrolled. Four groups were assessed: IM + 2 incisions (n = 546), SC + 2 incisions (n = 133), SC + 3 incisions (n = 111), and IM + 3 incisions (n = 15). DE was ≤65 J in 782 (97.1%) patients. Patients with DE ≤65 J showed a trend towards lower body mass index (25.1 vs. 26.5; p = .12), were less frequently on antiarrhythmic drugs (13% vs. 26%; p = .06) and more commonly underwent implantation with the 2-incision technique (85% vs. 70%; p = .04). The IM + 2-incision technique showed the lowest defibrillation failure rate (2.2%) and shock impedance (66 Ohm, interquartile range: 57-77). On multivariate analysis, the 2-incision technique was associated with a lower incidence of shock failure (hazard ratio: 0.305; 95% confidence interval: 0.102-0.907; p = .033). Shock impedance was lower with the IM than with the SC approach (66 vs. 70 Ohm p = .002) and with the 2-incision than the 3-incision technique (67 vs. 72 Ohm; p = .006). Conclusions: In a large population of S-ICD patients, we observed a high defibrillation success rate. The IM + 2-incision technique provides lower shock impedance and a higher likelihood of successful defibrillation

    Physical activity measured by implanted devices predicts atrial arrhythmias and patient outcome: Results of IMPLANTED (Italian Multicentre Observational Registry on Patients With Implantable Devices Remotely Monitored)

    Get PDF
    Background--To determine whether daily physical activity (PA), as measured by implanted devices (through accelerometer sensor), was related to the risk of developing atrial arrhythmias during long-term follow-up in a population of heart failure (HF) patients with an implantable cardioverter defibrillator (ICD). Methods and Results--The study population was divided into 2 equally sized groups (PA cutoff point: 3.5 h/d) according to their mean daily PA recorded by the device during the 30- to 60-day period post-ICD implantation. Propensity score matching was used to compare 2 equally sized cohorts with similar characteristics between lower and higher activity patients. The primary end point was time free from the first atrial high-rate episode (AHRE) of duration 656 minutes. Secondary end points were: first AHRE 656 hours, first AHRE 6548 hours, and a combined end point of death or HF hospitalization. Data from 770 patients (65\ub115 years; 66% men; left ventricular ejection fraction 35\ub112%) remotely monitored for a median of 25 months were analyzed. A PA =3.5 h/d was associated with a 38% relative reduction in the risk of AHRE 656 minutes (72-month cumulative survival: 75.0% versus 68.1%; log rank P=0.025), and with a reduction in the risk of AHRE 656 hours, AHRE 6548 hours, and the combined end point of death or HF hospitalization (all P < 0.05). Conclusions--In HF patients with ICD, a low level of daily PA was associated with a higher risk of atrial arrhythmias, regardless of the patients' baseline characteristics. In addition, a lower daily PA predicted death or HF hospitalization

    Telecardiology and Remote Monitoring of Implanted Electrical Devices: The Potential for Fresh Clinical Care Perspectives

    Get PDF
    Telecardiology may help confront the growing burden of monitoring the reliability of implantable defibrillators/pacemakers. Herein, we suggest that the evolving capabilities of implanted devices to monitor patients’ status (heart rhythm, fluid overload, right ventricular pressure, oximetry, etc.) may imply a shift from strictly device-centered follow-up to perspectives centered on the patient (and patient-device interactions). Such approaches could provide improvements in health care delivery and clinical outcomes, especially in the field of heart failure. Major professional, policy, and ethical issues will have to be overcome to enable real-world implementation. This challenge may be relevant for the evolution of our health care systems

    Strategies for customizing the cardiac resynchronization therapy

    Get PDF
    Solo il 60% dei candidati alla resincronizzazione cardiaca risponde in termini di rimodellamento ventricolare inverso che è il più forte predittore di riduzione della mortalità e delle ospedalizzazioni. Due cause possibili della mancata risposta sono la programmazione del dispositivo e i limiti dell’ approccio transvenoso. Nel corso degli anni di dottorato ho effettuato tre studi per ridurre il numero di non responder. Il primo studio valuta il ritardo interventricolare. Al fine di ottimizzare le risorse e fornire un reale beneficio per il paziente ho ricercato la presenza di predittori di ritardo interventricolare diverso dal simultaneo, impostato nella programmazione di base. L'unico predittore è risultato essere l’ intervallo QRS> 160 ms, quindi ho proposto una flow chart per ottimizzare solo i pazienti che avranno nella programmazione ottimale un intervallo interventricolare non simultaneo. Il secondo lavoro valuta la fissazione attiva del ventricolo sinistro con stent. I dislocamenti, la soglia alta di stimolazione del miocardio e la stimolazione del nervo frenico sono tre problematiche che limitano la stimolazione biventricolare. Abbiamo analizzato più di 200 angiografie per vedere le condizioni anatomiche predisponenti la dislocazione del catetere. Prospetticamente abbiamo deciso di utilizzare uno stent per fissare attivamente il catetere ventricolare sinistro in tutti i pazienti che presentavano le caratteristiche anatomiche favorenti la dislocazione. Non ci sono più state dislocazioni, c’è stata una migliore risposta in termini di rimodellamento ventricolare inverso e non ci sono state modifiche dei parametri elettrici del catetere. Il terzo lavoro ha valutato sicurezza ed efficacia della stimolazione endoventricolare sinistra. Abbiamo impiantato 26 pazienti giudicati non responder alla terapia di resincronizzazione cardiaca. La procedura è risultata sicura, il rischio di complicanze è simile alla stimolazione biventricolare classica, ed efficace nell’arrestare la disfunzione ventricolare sinistra e / o migliorare gli effetti clinici in un follow-up medio.Only 60% of the candidates for biventricular pacing responds in terms of left ventricular reverse remodeling that appears to be the strongest predictor of reduction in hospitalizations and mortality. The causes of non-response are not clear, but they could be found in the setting of the device and in the limitations of transvenous approach. I studied three problems looking strategies tailoring therapy of cardiac re synchronization to reduce the number of patients non-responders. The first study evaluates the interventricular delay. In order to optimize resources and provide a real benefit to the patient I researched the presence of predictors of the interventricular delay different from simultaneous, set in the basic programming. The only predictor of interventricular delay is QRS interval >160ms, so I proposed a flow chart to optimize only those patients who have a range in programming optimal interventricular not simultaneous. The second paper evaluates the active fixation of left ventricular lead. The displacements, the high threshold of myocardial stimulation and stimulation of the phrenic nerve appear to be three major problems that limit the biventricular pacing. We analyzed more than 200 angiograms to see the anatomical conditions predisposing displacement. Prospectively we decided to use a stent for the establishment of active left ventricular lead in all patients presenting with the anatomical features favoring the displacement. The active fixation has eliminated the problem of dislocations, improved response in terms of reverse ventricular remodeling and did not alter the electrical parameters of the lead. The third work evaluates left ventricular endocardial pacing. We implanted 26 patients judged to be non-responders to cardiac resynchronization therapy. The procedure was safe having a risk of complications at all comparable to classic biventricular pacing and effective in arresting the degeneration of heart failure and / or improve the clinical effects in the midterm follow-up
    • …