8 research outputs found

    Development of fast-response PPAC with strip-readout for heavy-ion beams

    Full text link
    A strip-readout parallel-plate avalanche counter (SR-PPAC) has been developed aiming at the high detection efficiency and good position resolution in high-intensity heavy-ion measurements. The performance was evaluated using 115 MeV/u 132^{132}Xe, 300 MeV/u 132^{132}Sn, and 300 MeV/u 48^{48}Ca beams. A detection efficiency beyond 99% for these beams is achieved even at an incident beam intensity of 0.7 billion particles per second. The best position resolution achieved is 235 um (FWHM).Comment: 16 pages, 18 figures, 2 table

    Decorating a single giant DNA with gold nanoparticles

    No full text
    We decorated a single giant DNA (1.66 × 105 base pairs) with gold nanoparticles through the simple procedure of mild warming, without denaturation of the DNA molecule. Single-molecule observation with fluorescence microscopy revealed that individual decorated DNA molecules stay in the bulk solution by avoiding aggregation and precipitation, and exhibit translational and conformational fluctuation, i.e., Brownian motion. An analysis of the intra-chain fluctuation of single DNA molecules revealed that the apparent spring constant and damping coefficient of a DNA chain increased by ca. 13- and 5-fold, respectively, upon decoration with gold nanoparticles. Observation by transmission electron microscopy revealed that gold nanoparticles were stably attached to the DNA skeleton. UV-visible measurements revealed the absence of any detectable change in surface plasmon resonance, suggesting that the gold nanoparticles assemble without the formation of a densely packed aggregate. CD measurements showed that the secondary structure of decorated DNA is still essentially the B-form.Spanish Ministerio de Economía y Competitividad CTQ2016-78703-PUniversidad de Sevilla 2010/00000762OTRI 2010/00000762JSPS KAKENHI 15H02121 2510301

    Experimental Challenges of the First Mass Measurement Campaign at the Rare-RI Ring

    No full text
    With the recent commissioning of the Rare-RI Ring (R3), nuclear mass measurement of rare isotopes (RIs) produced at the RI Beam Factory (RIBF) at RIKEN has become possible. The R3 spectrometer is based on the Isochronous Mass Spectrometry technique that allows for reaching a mass measurement precision of 10−6 within less than 1 ms. With the newly established self-triggered individual injection method, R3 specialized in mass measurements of extremely short-lived nuclei with low production yields. In this paper, we report the first mass measurement campaign conducted at the R3 addressing nuclei in the vicinity of N=50 and N=82 neutron magic numbers, with a particular focus on the challenges of this new facility

    National trends in the outcomes of subarachnoid haemorrhage and the prognostic influence of stroke centre capability in Japan: retrospective cohort study

    No full text
    Objectives To examine the national, 6-year trends in in-hospital clinical outcomes of patients with subarachnoid haemorrhage (SAH) who underwent clipping or coiling and the prognostic influence of temporal trends in the Comprehensive Stroke Center (CSC) capabilities on patient outcomes in Japan.Design Retrospective study.Setting Six hundred and thirty-one primary care institutions in Japan.Participants Forty-five thousand and eleven patients with SAH who were urgently hospitalised, identified using the J-ASPECT Diagnosis Procedure Combination database.Primary and secondary outcome measures Annual number of patients with SAH who remained untreated, or who received clipping or coiling, in-hospital mortality and poor functional outcomes (modified Rankin Scale: 3–6) at discharge. Each CSC was assessed using a validated scoring system (CSC score: 1–25 points).Results In the overall cohort, in-hospital mortality decreased (year for trend, OR (95% CI): 0.97 (0.96 to 0.99)), while the proportion of poor functional outcomes remained unchanged (1.00 (0.98 to 1.02)). The proportion of patients who underwent clipping gradually decreased from 46.6% to 38.5%, while that of those who received coiling and those left untreated gradually increased from 16.9% to 22.6% and 35.4% to 38%, respectively. In-hospital mortality of coiled (0.94 (0.89 to 0.98)) and untreated (0.93 (0.90 to 0.96)) patients decreased, whereas that of clipped patients remained stable. CSC score improvement was associated with increased use of coiling (per 1-point increase, 1.14 (1.08 to 1.20)) but not with short-term patient outcomes regardless of treatment modality.Conclusions The 6-year trends indicated lower in-hospital mortality for patients with SAH (attributable to better outcomes), increased use of coiling and multidisciplinary care for untreated patients. Further increasing CSC capabilities may improve overall outcomes, mainly by increasing the use of coiling. Additional studies are necessary to determine the effect of confounders such as aneurysm complexity on outcomes of clipped patients in the modern endovascular era
    corecore