107 research outputs found

    Optimal design and modeling of stand-alone hybrid PV-wind systems

    Get PDF

    Optimal scheduling of LTC and shunt capacitors in large distorted distribution systems using evolutionary-based algorithms

    Get PDF
    The optimal scheduling of load tap changers (LTCs) and switched shunt capacitors for simultaneously minimizing energy loss and improving voltage profile while taking harmonics into account is performed using evolutionary-based algorithms (EAs). The proposed algorithm is capable of optimizing large distribution systems with different types of nonlinear loads. The decouple approach is employed for harmonic power-flow calculations, while two EAs are developed to determine the load interval division and near-optimal schedule. The inclusion of harmonics provides the optimization benefits while maintaining the acceptable distortion levels. The scheduling is carried out for the IEEE 123-bus with 14 shunt capacitors and 12 nonlinear loads. The main contributions are inclusion of harmonics in the optimal scheduling problem and its application to large distribution systems with multiple nonlinear loads

    Effect of Surface Polishing on Mercury Release from Dental Amalgam After Treatment 16% Carbamide Peroxide Gel

    Get PDF
    Objectives: This study evaluated the effect of surface polishing on mercury release from dental amalgam after treatment with 16% carbamide peroxide gel.Materials and Methods: Ninety-six samples from two different amalgam brands were prepared in truncated cone-shaped PVC polymer molds with an external surface area of 195 mmÂČ. Half of the specimens were polished with green and red rubber, a brush and tin oxide paste at low speed. Samples were treated with 16% carbamide peroxide gel intubes containing 3 mL of carbamide peroxide gel and 0.1 mL of distilled water for 14 and 28 hours. Subsequently, carbamide peroxide gel on the sample surfaces was rinsed away with 7.0 mL of distilled water until the volume of each tube increased to 10 mL. Themercury level of each solution was measured using the VAV–440 mercury analyzer system.Considering the surface area of each amalgam disc, mercury amounts were calculated in ÎŒg ⁄mmÂČ. Data were analyzed using two-way ANOVA.Results: There were significant differences between the mean levels of mercury release from polished vs. unpolished amalgam surfaces after treatment with 16% carbamide peroxide.Increasing the storage time from 14 to 28 hours did not result in significant changes in the amount of mercury release. There was no significant interaction effect between amalgam surface polish and storage time statistically.Conclusion: Polished amalgam restorations release less mercury after treatment with carbamide peroxide bleaching gel in comparison with unpolished amalgam restorations

    Impact of intermittent misfire and fire-through on the performance of full converter based WECS

    Get PDF
    The integration of wind turbines into modern power grids has significantly increased during the last decade. The wind turbine equipped with full converter based wind energy Conversion System (FCWECS) represented about 20.3% of the worldwide total wind capacity in 2003. Since FCWECS is equipped with a voltage source inverter (VSI), it is vulnerable that misfire and fire-through may occur within the VSI switches. In this paper, impact of these switching malfunctions on FCWECS performance is investigated and discussed. Detailed simulations of the system under study are carried out using Matlab/Simulink to highlight the influence of these converter internal faults on PCC voltage, DC link voltage and shaft speed, as well as generator active and reactive power. Furthermore, compliance of the FCWECS with Spain fault ride through (FRT) grid codes is also investigated

    Developing a Questionnaire for Iranian Women's Attitude on Medical Ethics in Vaginal Childbirth

    Get PDF
    Background: Vaginal delivery is one of the challenging issues in medical ethics. It is important to use an appropriate instrument to assess medical ethics attitudes in normal delivery, but the lack of tool for this purpose is clear. Objectives: The aim of this study was to develop and validate a questionnaire for the assessment of women’s attitude on medical ethics application in normal vaginal delivery. Patients and Methods: This methodological study was carried out in Iran in 2013 - 2014. Medical ethics attitude in vaginal delivery questionnaire (MEAVDQ) was developed using the findings of a qualitative data obtained from a grounded theory research conducted on 20 women who had vaginal childbirth, in the first phase. Then, the validation criteria of this tool were tested by content and face validity in the second phase. Exploratory factor analysis was used for construct validity and reliability was also tested by Cronbach’s alpha coefficient in the third phase of this study. SPSS version 13 was used in this study. The sample size for construct validity was 250 females who had normal vaginal childbirth. Results: In the first phase of this study (tool development), by the use of four obtained categories and nine subcategories from grounded theory and literature review, three parts (98-items) of this tool were obtained (A, B and J). Part A explained the first principle of medical ethics, part B pointed to the second and third principles of medical ethics, and part J explained the fourth principle of medical ethics. After evaluating and confirming its face and content validity, 75 items remained in the questionnaire. In construct validity, by the employment of exploratory factor analysis, in parts A, B and J, 3, 7 and 3 factors were formed, respectively; and 62.8%, 64% and 51% of the total variances were explained by the obtained factors in parts A, B and J, respectively. The names of these factors in the three parts were achieved by consideration of the loading factor and medical ethics principles. The subscales of MEAVDQ showed significant reliability. In parts A, B and J, Cronbach’s alpha coefficients were 0.76, 0.72 and 0.68, respectively and for the total questionnaire, it was 0.72. The results of the test–retest were satisfactory for all the items (ICC = 0.60 - 0.95). Conclusions: The present study showed that the 59-item MEAVDQ was a valid and reliable questionnaire for the assessment of women’s attitudes toward medical ethics application in vaginal childbirth. This tool might assist specialists in making a judgment and plan appropriate for women in vaginal delivery management

    Multiwall Carbon Nanotubes Modified Carbon Paste Electrode for Determination of Copper(II) by Potentiometric and Impedimetric Methods

    Get PDF
    Abstract A chemically modified carbon paste electrode with multiwall carbon nanotube (MWCNT) was prepared and used as a sensor for Cu 2+ ion. The unique chemical and physical properties of CNT have paved the way to new and improved sensing devices. A central composite chemometrics design was applied for multivariate optimization of the effects of three significant parameters (Graphite powder (X 1 ), MWCNT (X 2 ) and Ionophre (X 3 )) influencing the response of the electrode. In the optimized conditions, the electrode exhibits a Nernstian slope of 30.1 mV/decade in a linear range between 1.0×10 -6 to1.0×10 -1 M over a wide pH range (2.0-6.5). Importantly, the effect of the MWCNT on the performance of electrode was investigated by impedance technique, that showed the MWCNT helps the transduction of the signal in carbon paste electrode and the charged transfer resistance (R ct ) was reduced. The impedimetric results indicated that the linear concentrations range was 1.0×10 −7 to 1.0×10 −1 M and in comparison with potentiometry, the pH range increased to 2.0−7.5. JNS All rights reserve

    Comparison of non-invasive to invasive oxygenation ratios for diagnosing acute respiratory distress syndrome following coronary artery bypass graft surgery: a prospective derivation-validation cohort study

    Get PDF
    Objective: To determine if non-invasive oxygenation indices, namely peripheral capillary oxygen saturation (SpO2)/ fraction of inspired oxygen (Fi O2) and partial pressure of alveolar oxygen (PAO2)/Fi O2 may be used as effective surrogates for the partial pressure of arterial oxygen (PaO2)/Fi O2. Also, to determine the SpO2/Fi O2 and PAO2/Fi O2 values that correspond to PaO2/Fi O2 thresholds for identifying acute respiratory distress syndrome (ARDS) in patients following coronary artery bypass graft (CABG) surgery. Methods: A prospective derivation-validation cohort study in the Open-Heart ICU of an academic teaching hospital. Recorded variables included patient demographics, ventilator settings, chest radiograph results, and SPO2, PaO2, PAO2, SaO2, and Fi O2. Linear regression modeling was used to quantify the relationship between indices. Receiver operating characteristic (ROC) curves were used to determine the sensitivity and specificity of the threshold values. Results: One-hundred seventy-five patients were enrolled in the derivation cohort, and 358 in the validation cohort. The SPO2/Fi O2 and PAO2/Fi O2 ratios could be predicted well from PaO2/Fi O2, described by the linear regression models SPO2/Fi O2 = 71.149 + 0.8PF and PAO2/Fi O2 = 38.098 + 2.312PF, respectively. According to the linear regression equation, a PaO2/Fi O2 ratio of 300 equaled an SPO2/Fi O2 ratio of 311 (R2 0.857, F 1035.742, < 0.0001) and a PAO2/Fi O2 ratio of 732 (R2 0.576, F 234.887, < 0.0001). The SPO2/Fi O2 threshold of 311 had 90% sensitivity, 80% specificity, LR+ 4.50, LR- 0.13, PPV 98, and NPV 42.1 for the diagnosis of mild ARDS. The PAO2/Fi O2 threshold of 732 had 86% sensitivity, 90% specificity, LR+ 8.45, LR- 0.16, PPV 98.9, and NPV 36 for the diagnosis of mild ARDS. SPO2/ Fi O2 had excellent discrimination ability for mild ARDS (AUC ± SE = 0.92 ± 0.017; 95% CI 0.889 to 0.947) as did PAO2/ Fi O2 (AUC ± SE = 0.915 ± 0.018; 95% CI 0.881 to0.942). Conclusions: PaO2 and SaO2 correlated in the diagnosis of ARDS, with a PaO2/Fi O2 of 300 correlating to an SPO2/ Fi O2 of 311 (Sensitivity 90%, Specificity 80%). The SPO2/ Fi O2 ratio may allow for early real-time rapid identification of ARDS, while decreasing the cost, phlebotomy, blood loss, pain, skin breaks, and vascular punctures associated with serial arterial blood gas measurements

    Primary neuroendocrine neoplasm of the esophagus – Report of 14 cases from a single institute and review of the literature

    Full text link

    Coordination of Generation Scheduling with PEVs Charging in Industrial Microgrids

    No full text
    Conventional industrial microgrids (IMGs) consist of factories with distributed energy resources (DERs) and electric loads that rely on combined heat and power (CHP) systems while the developing IMGs are expected to also include renewable DERs and plug-in electric vehicles (PEVs) with different vehicle ratings and charging characteristics. This paper presents an electricity and heat generation scheduling method coordinated with PEV charging in an IMG considering photovoltaic (PV) generation systems coupled with PV storages. The proposed method is based on dynamic optimal power flow (DOPF) over a 24-hour period and includes security-constrained optimal power flow (SCOPF), IMG's factories constraints, PV storage constraints and PEVs dynamic charging constraints. It will utilize the generators waste heat to fulfill thermal requirements while considering the status of renewable DERs to decrease the overall cost of IMGs. To demonstrate the effectiveness of the proposed method, detailed simulation results are presented and analyzed for an 18-bus IMG consisting of 12 factories and 6 types of PEVs without/with PV generation systems operating in grid-connected and stand-alone modes. The main contribution is including PEVs with dynamic constraints that have changed the nature of scheduling formulation from a simple hourly OPF to a dynamic OPF
    • 

    corecore