39 research outputs found

    SARS-CoV-2 infection serology: a useful tool to overcome lockdown?

    Get PDF
    The outbreak of 2019 novel coronavirus disease (Covid-19) caused by SARS-CoV-2 has spread rapidly, inducing a progressive growth in infected patients number. Social isolation (lockdown) has been assessed to prevent and control virus diffusion, leading to a worldwide financial and political crisis. Currently, SARS-CoV-2 RNA detection in nasopharyngeal swab takes place by real-time PCR (RT-qPCR). However, molecular tests can give some false-negative results. In this context, serological assays can be useful to detect IgG/IgM antibodies, to assess the degree of immunization, to trace the contacts, and to support the decision to re-admit people at work. A lot of serological diagnostic kits have been proposed on the market but validation studies have not been published for many of them. The aim of our work was to compare and to evaluate different assays analytical performances (two different immunochromatographic cards, an immunofluorescence chromatographic card, and a chemiluminescence-automated immunoassay) on 43 positive samples with RT-qPCR-confirmed SARS-CoV-2 infection and 40 negative control subjects. Our data display excellent IgG/IgM specificities for all the immunocromatographic card tests (100% IgG and 100% IgM) and for the chemiluminescence-automated assay (100% IgG and 94% IgM); IgG/IgM sensitivities are moderately lower for all methods, probably due to the assay viral antigen's nature and/or to the detection time of nasopharyngeal swab RT-qPCR, with respect to symptoms onset. Given that sensitivities (around 94% and 84% for IgG and IgM, respectively) implicate false-negative cases and given the lack of effective vaccines or treatments, the only currently available procedure to reduce SARS-CoV-2 transmission is to identify and isolate persons who are contagious. For this reason, we would like to submit a flowchart in which serological tests, integrated with nasopharyngeal swab RT-qPCR, are included to help social and work activities implementation after the pandemic acute phase and to overcome lockdown

    Thermodynamic description of the effect of the mutation Y49F on human glutathione transferase P1-1 in binding with glutathione and the inhibitor S-hexylglutathione.

    Get PDF
    The thermodynamics of binding of both the substrate glutathione (GSH) and the competitive inhibitor S-hexylglutathione to the mutant Y49F of human glutathione S-transferase (hGST P1-1), a key residue at the dimer interface, has been investigated by isothermal titration calorimetry and fluorescence spectroscopy. Calorimetric measurements indicated that the binding of these ligands to both the Y49F mutant and wild-type enzyme is enthalpically favorable and entropically unfavorable over the temperature range studied. The affinity of these ligands for the Y49F mutant is lower than those for the wild-type enzyme due mainly to an entropy change. Therefore, the thermodynamic effect of this mutation is to decrease the entropy loss due to binding. Calorimetric titrations in several buffers with different ionization heat amounts indicate a release of protons when the mutant binds GSH, whereas protons are taken up in binding S-hexylglutathione at pH 6.5. This suggests that the thiol group of GSH releases protons to buffer media during binding and a group with low pKa (such as Asp98) is responsible for the uptake of protons. The temperature dependence of the free energy of binding, DeltaG0, is weak because of the enthalpy-entropy compensation caused by a large heat capacity change. The heat capacity change is -199.5 +/- 26.9 cal K-1 mol-1 for GSH binding and -333.6 +/- 28.8 cal K-1 mol-1 for S-hexylglutathione binding. The thermodynamic parameters are consistent with the mutation Tyr49 --Phe, producing a slight conformational change in the active site

    Low Vitamin D Status at Admission as a Risk Factor for Poor Survival in Hospitalized Patients With COVID-19: An Italian Retrospective Study

    Get PDF
    Preliminary findings suggest a relationship between lower serum 25-hydroxyvitamin D [25(OH)D] levels and incidence and severity of COVID-19. The aim of this study was to evaluate the relationship between vitamin D status at admission and different markers of inflammation, coagulation, and sepsis in hospitalized patients with COVID-19

    Temperature adaptation of glutathione S-transferase P1-1. A case for homotropic regulation of substrate binding.

    Get PDF
    Human glutathione S-transferase P1-1 (GST P1-1) is a homodimeric enzyme expressed in several organs as well as in the upper layers of epidermis, playing a role against carcinogenic and toxic compounds. A sophisticated mechanism of temperature adaptation has been developed by this enzyme. In fact, above 35 degrees C, glutathione (GSH) binding to GST P1-1 displays positive cooperativity, whereas negative cooperativity occurs below 25 degrees C. This binding mechanism minimizes changes of GSH affinity for GST P1-1 because of temperature fluctuation. This is a likely advantage for epithelial skin cells, which are naturally exposed to temperature variation and, incidentally, to carcinogenic compounds, always needing efficient detoxifying systems. As a whole, GST P1-1 represents the first enzyme which displays a temperature-dependent homotropic regulation of substrate (e.g. GSH) binding

    Evaluation of S-RBD and high specificity ACE-2-binding antibodies on SARS-CoV-2 patients after six months from infection

    Get PDF
    The antibody response to SARS-CoV-2 has not yet fully defined, but the availability of sensitive and specific serological assays is crucial to observe the presence of specific antibodies against the human receptor binding domain (S-RBD) and high specificity ACE-2-binding antibodies or neutralizing antibodies (NT) in response to vaccines. Indeed, these peculiar antibodies should prevent viral interaction between RBD and AngiotensinConverting Enzyme 2 (ACE2) receptor, located on surface of host cells. In this study, 72 samples from 37 hospitalized COVID-19 patients and 35 not-hospitalized patients were analyzed longitudinally. The detection of SRBD and NT antibodies was carried out using CLIA tests. Hospitalized patients showed elevated serum levels of S-RBD (97.22%) and NT (77.78%) antibodies, differently, not-hospitalized, who were paucisymptomatic or asymptomatic patients, showed lower serum levels of SRBD (65.71%) and NT (38.14%) antibodies. The results suggest that the NT serum level is strongly related to disease severity (p < 0.001) and to the serum level of S-RBD antibodies (p < 0.0001)

    Evaluation of the accuracy in the mucosal detection of anti-SARS-CoV-2 antibodies in nasal secretions and saliva

    No full text
    COVID-19 vaccination with mRNA vaccines induces immune responses capable of neutralizing SARS-CoV-2. Commercially available serological anti-SARS-CoV-2 quantitative and neutralizing assays are essential for the determination of immune responses to vaccines. Nevertheless, at present there is a lack of validated tests to assess the mucosal response to COVID-19 vaccination and standardized analytic and pre-analytic methods have not yet been defined. The aim of our study was to evaluate the accuracy of two diagnostic immunoassays for COVID-19 (ELISA for IgA-S1 and chemiluminescent assay for IgG-RBD) on serum, saliva, and nasal secretions, by the enrollment of three study populations (healthy controls, vaccinated subjects, and subjects recovered from COVID-19 infection). In order to obtain an appropriate cut-off value for the biological matrices studied, ROC curve analyses were performed. Data demonstrate that the analytical and pre-analytical method we have developed can provide accurate and reliable results for the detection of anti-SARS-CoV-2 mucosal specific an-tibodies (IgA-S1 and IgG-RBD) on saliva and, as a novelty, on nasal secretions, either after COVID-19 infection or in vaccinated subjects

    Antibody response to COVID-19 vaccine: A point of view that can help to optimize dose distribution

    No full text
    The global strategy to control coronavirus disease is based on the availability of COVID-19 vaccines. More information about response to a single dose vaccine could help to better understand and optimize the management of the vaccine campaign. Workers from the University of Rome ``Tor Vergata{''} and the University Hospital of University of Rome ``Tor Vergata,{''} were monitored during their vaccination program. Serum samples were collected between the first and second dose and after the second dose. University personnel has been vaccinated with two doses of Vaxzevria vaccine 12 weeks apart, while hospital personnel has been vaccinated with two doses of Comirnaty 3 weeks apart. IgG antibodies (Abs) against the Receptor Binding Domain (RBD) of the virus spike surface glycoprotein and neutralizing antibodies (NT) anti-SARS-CoV-2 that block the interaction between RBD and the surface receptor cellular angiotensin converting enzyme (ACE2) were measured using the CL-series Mindray chemiluminescent assays, respectively. Different amounts of antibodies produced after the two doses of vaccine were found. Individuals with a previous natural infection developed a higher Abs titer. Among the individuals with no history of past SARS-CoV-2 infection, 5\% had an Abs level of the same order of magnitude of infected people, suggesting that they acquired the infection in an asymptomatic way. In such individuals, one dose of vaccine may be sufficient to obtain a protective immune response

    Evaluation of serological anti-SARS-CoV-2 chemiluminescent immunoassays correlated to live virus neutralization test, for the detection of anti-RBD antibodies as a relevant alternative in COVID-19 large-scale neutralizing activity monitoring

    No full text
    The Spike-Receptor Binding Domain (S-RBD) is considered the most antigenic protein in SARS-CoV-2 and probably the key player in SARS-CoV-2 immune response. Quantitative immunoassays may help establish an anti-RBD Abs threshold as an indication of protective immunity. Since different immunoassays are commercial, the standard reference method for the neutralizing activity is the live Virus Neutralization Test (VNT). In this study, anti-RBD IgG levels were detected with two chemiluminescent immunoassays in paucisympto-matic, symptomatic and vaccinated subjects, and their neutralizing activity was correlated to VNT titer, using SARS-CoV-2 original and British variant strains. Both immunoassays confirmed higher anti-RBD Abs levels in vaccinated subjects. Furthermore, despite different anti-RBD Abs median concentrations between the immunoassays, a strong positive correlation with VNT was observed. In conclusion, although the SARS-CoV-2 immune response heterogeneity, the use of immunoassays can help in large-scale monitoring of COVID-19 samples, becoming a valid alternative to VNT test for diagnostic routine laboratories

    Uterine and placental blood flow indexes and antinuclear autoantibodies in unexplained recurrent pregnancy loss: should they be investigated in pregnancy as correlated potential factors? A retrospective study

    No full text
    The potential role of antinuclear antibodies (ANA) in recurrent pregnancy loss (RPL) pathogenesis is still debated, although some evidences suggest that they could affect pregnancy outcome, leading to a higher miscarriage rate in these patients. A hypothesized mechanism is through changes in uterine flow in pre-conceptional stage, by modifying endometrial receptivity in RPL. However, scant data are available, in pregnancy, about their role in RPL placental perfusion, also in relation to its potential treatments, such as low molecular weight heparin (LMWH). The aim of this study is to retrospectively further investigate the correlation between two-dimensional (2D) and three-dimensional (3D) uterine and placental flow indexes and the presence or the absence of ANA in women with unexplained RPL (uRPL), treated or not treated with LMWH

    Site-directed mutagenesis of human glutathione transferase P1-1. Mutation of Cys-47 induces a positive cooperativity in glutathione transferase P1-1.

    No full text
    Glutathione transferase P1-1 (EC 2.5.1.18) is a dimeric enzyme composed of identical subunits each containing one binding site for GSH and a second for the co-substrate e.g. 1-chloro-2,4-dinitrobenzene. Steady-state kinetics are strictly hyperbolic toward both these substrates. Replacement of Cys-47 with alanine or serine decreases the affinity for GSH and triggers a positive kinetic cooperativity with respect to this substrate. Hill coefficients were 1.31 and 1.43 for the C47A and C47S mutants. C47A/C101A and C47S/C101S double mutants display lower affinity for GSH and higher Hill coefficients (1.57 and 1.56, respectively) when compared with C47A and C47S single mutants. Conversely, replacement of Cys-101 with alanine or serine does not yield any cooperativity and any marked change of kinetic parameters. Fluorometric experiments gave sigmoidal isothermic GSH binding curves for all the Cys-47 mutants, with Hill coefficients similar to that obtained by the kinetic approach. These data, together with the activation experiments performed in the presence of S-hexylglutathione, suggest that the substitution of Cys-47 yields a dimeric low-affinity enzyme which can be converted to a higher affinity state upon binding of GSH on one subunit. These findings indicate a structural communication between subunits which may be revealed by the lack of a peculiar electrostatic bond between the thiolate form of Cys-47 and the protonated amino group of Lys-54
    corecore