16 research outputs found

    A new echocardiographic model for quantifying three-dimensional endocardial surface area

    Get PDF
    A new technique for quantitatively mapping the three-dimensional left ventricular endocardial surface was developed, using measurements from standard cross-sectional echocardiographic images. To validate the accuracy of this echocardiographic mapping technique in an animal model, the endocardial areas of 15 excised canine ventricles were calculated using measurements made from echocardiographic studies of the hearts and compared with areas determined with latex casts of the same ventricles. Close correlation (r = 0.87, p < 0.001) between these two measures of endocardial area provided preliminary confirmation of the accuracy of the maps.To further characterize the mapping algorithm, it was translated into computer format and used to map the surfaces of idealized hemiellipsoids. Areas measured with this mapping technique closely approximated the actual areas of idealized surfaces with a wide spectrum of shapes; maps were particularly accurate for ellipsoids with shapes similar to those of undistorted human ventricles. Also, the accuracies of area calculations were relatively insensitive to deviation from the assumed positions of the echocardiographic short-axis planes. Finally, although the accuracy of the mapping technique improved as data from more transverse planes were added, the procedure proved reliable for estimating surface areas when data from only three planes were used. These studies confirm the accuracy of the echocardiographic mapping technique, and they suggest that the resulting planar plots might be useful as templates for localizing and quantifying the overall extent of abnormal wall motion

    Pseudoaneurysm of the pulmonary artery after the banding procedure: Two-dimensional echocardiographic description

    Get PDF
    This report describes an infant with double-outlet right ventricle who underwent pulmonary artery banding as palliation for excessive left to right shunting through a ventricular septal defect. Three weeks after this procedure, there was abrupt clinical deterioration, and two-dimensional echocardiography clearly defined a large pseudoaneurysm arising from a breach in the posterior pulmonary artery wall, just proximal to the band. The diagnosis was confirmed at surgery, during which total correction was performed with successful outcome. The two-dimensional echocardiographic features of a pseudoaneurysm of the pulmonary artery are shown and the role of this noninvasive technique in the evaluation of pulmonary artery bands is discussed
    corecore