5 research outputs found

    Active Wnt signaling in response to cardiac injury

    Get PDF
    Although the contribution of Wnt signaling in infarct healing is suggested, its exact role after myocardial infarction (MI) still needs to be unraveled. We evaluated the cardiac presence of active Wnt signaling in vivo following MI, and investigated in which cell types active Wnt signaling was present by determining Axin2 promoter-driven LacZ expression. C57BL/6 Axin2-LacZ reporter mice were sacrificed at days 0, 1, 3, 7, 14, and 21 after LAD ligation. Hearts were snap-frozen for immunohistochemistry (IHC) or enzymatically digested to obtain a single cell suspension for flow cytometric analysis. For both FACS and IHC, samples were stained for β-galactosidase and antibodies against Sca-1, CD31, ckit, and CD45. Active Wnt signaling increased markedly in the myocardium, from 7 days post-MI onwards. Using Sca-1 and CD31, to identify progenitor and endothelial cells, a significant increase in LacZ+ cells was found at 7 and 14 days post-MI. LacZ+ cells also increased in the ckit+ and CD45+ cell population. IHC revealed LacZ+ cells co-expressing Sca, CD31, CD45, vWF, and αSMA in the border zone and the infarcted area. Wnt signaling increased significantly after MI in Sca+- and CD31+-expressing cells, suggesting involvement of Wnt signaling in resident Sca+ progenitor cells, as well as endothelial cells. Moreover, active Wnt signaling was present in ckit+ cells, leukocytes, and fibroblast. Given its broad role during the healing phase after cardiac injury, additional research seems warranted before a therapeutic approach on Wnt to enhance cardiac regeneration can be carried out safely

    Propensity score-based analysis of long-term outcome of patients on HeartWare and HeartMate 3 left ventricular assist device support

    Get PDF
    AIMS: Left ventricular assist device therapy has become the cornerstone in the treatment of end-stage heart failure and is increasingly used as destination therapy next to bridge to transplant or recovery. HeartMate 3 (HM3) and HeartWare (HVAD) are centrifugal continuous flow devices implanted intrapericardially and most commonly used worldwide. No randomized controlled trials have been performed yet. Analysis based on large registries may be considered as the best alternative but has the disadvantage of different standard of care between centres and missing data. Bias is introduced, because the decision which device to use was not random, even more so because many centres use only one type of left ventricular assist device. Therefore, we performed a propensity score (PS)-based analysis of long-term clinical outcome of patients that received HM3 or HVAD in a single centre. METHODS AND RESULTS: Between December 2010 and December 2019, 100 patients received HVAD and 81 patients HM3 as primary implantation at the University Medical Centre Utrecht. We performed PS matching with an extensive set of covariates, resulting in 112 matched patients with a median follow-up of 28 months. After PS matching, survival was not significantly different (P = 0.21) but was better for HM3. The cumulative incidences for haemorrhagic stroke (P = 0.01) and pump thrombosis (P = 0.02) were significantly higher for HVAD patients. The cumulative incidences for major bleeding, ischaemic stroke, right heart failure, and driveline infection were not different between the groups. We found no interaction between the surgeon who performed the implantation and survival (P = 0.59, P = 0.78, and P = 0.89). Sensitivity analysis was performed, by PS matching without patients on preoperative temporary support resulting in 74 matched patients. This also resulted in a non-significant difference in survival (P = 0.07). The PS-adjusted Cox regression showed a worse but non-significant (P = 0.10) survival for HVAD patients with hazard ratio 1.71 (95% confidence interval 0.91-3.24). CONCLUSIONS: Survival was not significantly different between both groups after PS matching, but was better for HM3, with a significantly lower incidence of haemorrhagic stroke and pump thrombosis for HM3. These results need to be interpreted carefully, because matching may have introduced greater imbalance on unmeasured covariates. A multicentre approach of carefully selected centres is recommended to enlarge the number of matched patients

    Propensity score-based analysis of long-term outcome of patients on HeartWare and HeartMate 3 left ventricular assist device support

    No full text
    AIMS: Left ventricular assist device therapy has become the cornerstone in the treatment of end-stage heart failure and is increasingly used as destination therapy next to bridge to transplant or recovery. HeartMate 3 (HM3) and HeartWare (HVAD) are centrifugal continuous flow devices implanted intrapericardially and most commonly used worldwide. No randomized controlled trials have been performed yet. Analysis based on large registries may be considered as the best alternative but has the disadvantage of different standard of care between centres and missing data. Bias is introduced, because the decision which device to use was not random, even more so because many centres use only one type of left ventricular assist device. Therefore, we performed a propensity score (PS)-based analysis of long-term clinical outcome of patients that received HM3 or HVAD in a single centre. METHODS AND RESULTS: Between December 2010 and December 2019, 100 patients received HVAD and 81 patients HM3 as primary implantation at the University Medical Centre Utrecht. We performed PS matching with an extensive set of covariates, resulting in 112 matched patients with a median follow-up of 28 months. After PS matching, survival was not significantly different (P = 0.21) but was better for HM3. The cumulative incidences for haemorrhagic stroke (P = 0.01) and pump thrombosis (P = 0.02) were significantly higher for HVAD patients. The cumulative incidences for major bleeding, ischaemic stroke, right heart failure, and driveline infection were not different between the groups. We found no interaction between the surgeon who performed the implantation and survival (P = 0.59, P = 0.78, and P = 0.89). Sensitivity analysis was performed, by PS matching without patients on preoperative temporary support resulting in 74 matched patients. This also resulted in a non-significant difference in survival (P = 0.07). The PS-adjusted Cox regression showed a worse but non-significant (P = 0.10) survival for HVAD patients with hazard ratio 1.71 (95% confidence interval 0.91-3.24). CONCLUSIONS: Survival was not significantly different between both groups after PS matching, but was better for HM3, with a significantly lower incidence of haemorrhagic stroke and pump thrombosis for HM3. These results need to be interpreted carefully, because matching may have introduced greater imbalance on unmeasured covariates. A multicentre approach of carefully selected centres is recommended to enlarge the number of matched patients

    Therapeutic Delivery of miR-148a Suppresses Ventricular Dilation in Heart Failure

    Get PDF
    Heart failure is preceded by ventricular remodeling, changes in left ventricular mass, and myocardial volume after alterations in loading conditions. Concentric hypertrophy arises after pressure overload, involves wall thickening, and forms a substrate for diastolic dysfunction. Eccentric hypertrophy develops in volume overload conditions and leads wall thinning, chamber dilation, and reduced ejection fraction. The molecular events underlying these distinct forms of cardiac remodeling are poorly understood. Here, we demonstrate that miR-148a expression changes dynamically in distinct subtypes of heart failure: while it is elevated in concentric hypertrophy, it decreased in dilated cardiomyopathy. In line, antagomir-mediated silencing of miR-148a caused wall thinning, chamber dilation, increased left ventricle volume, and reduced ejection fraction. Additionally, adeno-associated viral delivery of miR-148a protected the mouse heart from pressure-overload-induced systolic dysfunction by preventing the transition of concentric hypertrophic remodeling toward dilation. Mechanistically, miR-148a targets the cytokine co-receptor glycoprotein 130 (gp130) and connects cardiomyocyte responsiveness to extracellular cytokines by modulating the Stat3 signaling. These findings show the ability of miR-148a to prevent the transition of pressure-overload induced concentric hypertrophic remodeling toward eccentric hypertrophy and dilated cardiomyopathy and provide evidence for the existence of separate molecular programs inducing distinct forms of myocardial remodeling. Raso et al. show that miR-148a is elevated in concentric hypertrophy and decreased in dilated cardiomyopathy. Adeno-associated viral delivery of miR-148a protects the mouse heart from cardiac dilation. Mechanistically, miR-148a regulates the sensitivity of the heart to extracellular cytokines
    corecore