325 research outputs found

    Whole transcriptome analysis of bovine mammary progenitor cells by P-Cadherin enrichment as a marker in the mammary cell hierarchy

    Get PDF
    Adult bovine mammary stem cells possess the ability to regenerate in vivo clonal outgrowths that mimic functional alveoli. Commonly available techniques that involve immunophenotype-based cell sorting yield cell fractions that are moderately enriched, far from being highly purified. Primary bovine mammary epithelial cells segregated in four different populations according to the expression of P-Cadherin and CD49f. Sorted cells from each fraction were tested for the presence of lineagerestricted progenitors and stem cells. Only cells from the CD49fhigh/ P-C adherinneg subpopulation were able to give rise to both luminal- and myoepithelial-restricted colonies in vitro and generate organized outgrowths in vivo, which are hallmarks of stem cell activity. After whole transcriptome analysis, we found gene clusters to be differentially enriched that relate to cell-to-cell communication, metabolic processes, proliferation, migration and morphogenesis. When we analyzed only the genes that were differentially expressed in the stem cell enriched fraction, clusters of downregulated genes were related to proliferation, while among the upregulated expression, cluster of genes related to cell adhesion, migration and cytoskeleton organization were observed. Our results show that P-C adherin separates mammary subpopulations differentially in progenitor cells or mammary stem cells. Further we provide a comprehensive observation of the gene expression differences among these cell populations which reinforces the assumption that bovine mammary stem cells are typically quiescent

    Use of Diltiazem in Chronic Rate Control for Atrial Fibrillation: A Prospective Case-Control Study

    Get PDF
    Atrial fibrillation (AF) is a multifaceted disease requiring personalised treatment. The aim of our study was to explore the prognostic impact of a patient-specific therapy (PT) for rate control, including the use of non-dihydropyridine calcium channel blockers (NDDC) in patients with heart failure (HF) or in combination with beta-blockers (BB), compared to standard rate control therapy (ST), as defined by previous ESC guidelines. This is a single-centre prospective observational registry on AF patients who were followed by our University Hospital. We included 1112 patients on an exclusive rate control treatment. The PT group consisted of 125 (11.2%) patients, 93/125 (74.4%) of whom were prescribed BB + NDCC (±digoxin), while 85/125 (68.0%) were HF patients who were prescribed NDCC, which was diltiazem in all cases. The patients treated with a PT showed no difference in one-year overall survival compared to those with an ST. Notably, the patients with HF in ST had a worse prognosis (p < 0.001). To better define this finding, we performed three sensitivity analyses by matching each patient in the PT subgroups with three subjects from the ST cohort, showing an improved one-year survival of the HF patients treated with PT (p = 0.039). Our results suggest a potential outcome benefit of NDCC for rate control in AF patients, either alone or in combination with BB and in selected patients with HF

    Cardiac resynchronization therapy: a comparison among left ventricular bipolar, quadripolar and active fixation leads

    Get PDF
    We evaluated the performance of 3 different left ventricular leads (LV) for resynchronization therapy: bipolar (BL), quadripolar (QL) and active fixation leads (AFL). We enrolled 290 consecutive CRTD candidates implanted with BL (n = 136) or QL (n = 97) or AFL (n = 57). Over a minimum 10 months follow-up, we assessed: (a) composite technical endpoint (TE) (phrenic nerve stimulation at 8 [email protected] ms, safety margin between myocardial and phrenic threshold <2V, LV dislodgement and failure to achieve the target pacing site), (b) composite clinical endpoint (CE) (death, hospitalization for heart failure, heart transplantation, lead extraction for infection), (c) reverse remodeling (RR) (reduction of end systolic volume >15%). Baseline characteristics of the 3 groups were similar. At follow-up the incidence of TE was 36.3%, 14.3% and 19.9% in BL, AFL and QL, respectively (p < 0.01). Moreover, the incidence of RR was 56%, 64% and 68% in BL, AFL and QL respectively (p = 0.02). There were no significant differences in CE (p = 0.380). On a multivariable analysis, “non-BL leads” was the single predictor of an improved clinical outcome. QL and AFL are superior to conventional BL by enhancing pacing of the target site: AFL through prevention of lead dislodgement while QL through improved management of phrenic nerve stimulation

    The Challenges of Diagnosis and Treatment of Arrhythmogenic Cardiomyopathy: Are We there yet?

    Get PDF
    Background: we sought to review the evolution in the diagnosis and treatment of Arrhythmogenic Cardiomyopathy (ACM), a clinically multifaceted entity beyond the observation of ventricular arrhythmias, and the outcome of therapies aiming at sudden death prevention in a single center experience. Methods: retrospective analysis of the data of consecutive patients with an implanted cardioverter-defibrillator (ICD) and a confirmed diagnosis of ACM according to the proposed Padua Criteria, who were referred to our center from January 1992 to October 2021. Results: we enrolled 72 patients (66% males, mean age at implant 46 ± 16 years), 63.9% implanted for primary prevention. At the time of ICD implant, 29 (40.3%) patients had a right ventricular involvement, 24 (33.3%) had a dominant LV involvement and 19 (26.4%) had a biventricular involvement. After a median follow-up of 6,1 years [IQR: 2.5–9.9], 34 patients (47.2%) had 919 sustained episodes of ventricular arrhythmias (VA). 27 patients (37.5%) had 314 episodes of life-threatening arrhythmias (LT-VA), defined as sustained ventricular tachycardia ≥200 beats/min. Considering only the patients with an ICD capable of delivering ATP, 80.4% of VA and 65% of LT-VA were successfully terminated with ATP. 16 (22.2%) patients had an inappropriate ICD activation, mostly caused by atrial fibrillation, while in 9 patients (12.5%) there was a complication needing reintervention (in 3 cases there was a loss of ventricular sensing dictating lead revision). During the follow-up 11 (15.3%) patients died, most of them due to heart failure, and 8 (11.1%) underwent heart transplantation. Conclusions: ACM is increasingly diagnosed owing to heightened suspicion at ECG examination and to improved imaging technology and availability, though the diagnostic workflow is particularly challenging in the earliest disease stages. ICD therapy is the cornerstone of sudden death prevention, albeit its efficacy is not based on controlled studies, and VT ablation/medical therapy are complementary to this strategy. The high burden of ATP-terminated VA makes shock-only devices debatable. The progressive nature of ACM leads to severe biventricular enlargement and refractory heart failure, which pose significant treatment issues when a predominant RV dysfunction occurs owing to the reduced possibility for mechanical circulatory assistance

    Is Less Always More? A Prospective Two-Centre Study Addressing Clinical Outcomes in Leadless versus Transvenous Single-Chamber Pacemaker Recipients

    Get PDF
    (1) Background: Leadless (LL) stimulation is perceived to lower surgical, vascular, and lead-related complications compared to transvenous (TV) pacemakers, yet controlled studies are lacking and real-life experience is non-conclusive. (2) Aim: To prospectively analyse survival and complication rates in leadless versus transvenous VVIR pacemakers. (3) Methods: Prospective analysis of mortality and complications in 344 consecutive VVIR TV and LL pacemaker recipients between June 2015 and May 2021. Indications for VVIR pacing were “slow” AF, atrio-ventricular block in AF or in sinus rhythm in bedridden cognitively impaired patients. LL indication was based on individualised clinical judgement. (4) Results: 72 patients received LL and 272 TV VVIR pacemakers. LL pacemaker indications included ongoing/expected chronic haemodialysis, superior venous access issues, active lifestyle with low pacing percentage expected, frailty causing high bleeding/infectious risk, previous valvular endocarditis, or device infection requiring extraction. No significant difference in the overall acute and long-term complication rate was observed between LL and TV cohorts, with greater mortality occurring in TV due to selection of older patients. (5) Conclusions: Given the low complication rate and life expectancy in this contemporary VVIR cohort, extending LL indications to all VVIR candidates is unlikely to provide clear-cut benefits. Considering the higher costs of LL technology, careful patient selection is mandatory for LL PMs to become advantageous, i.e., in the presence of vascular access issues, high bleeding/infectious risk, and long life expectancy, rendering lead-related issues and repeated surgery relevant in the long-term perspective

    Bridging the future of cardiac stimulation: physiologic or leadless pacing?

    Get PDF
    Cardiac simulation has moved from early life-saving pacemakers meant only to prevent asystole to current devices capable of physiologic stimulation for the treatment of heart rhythm and heart failure, that are also intended for remote patient and disease-progression monitoring. The actual vision of contemporary pacing aims to correct the electrophysiologic roots of mechanical inefficiency regardless of underlying structural heart diseases. The awareness of the residual cardiac dyssynchrony related to customary cardiac pacing has changed the concept of what truly represents “physiologic pacing”. On a different perspective, leadless stimulation to abolish CIED surgery and prevent lead-related complications is becoming a priority both for young device recipients and for frail, elderly patients. Careful clinical evaluation attempts to bridge decision-making to patient-tailored therapy

    Telecardiology and Remote Monitoring of Implanted Electrical Devices: The Potential for Fresh Clinical Care Perspectives

    Get PDF
    Telecardiology may help confront the growing burden of monitoring the reliability of implantable defibrillators/pacemakers. Herein, we suggest that the evolving capabilities of implanted devices to monitor patients’ status (heart rhythm, fluid overload, right ventricular pressure, oximetry, etc.) may imply a shift from strictly device-centered follow-up to perspectives centered on the patient (and patient-device interactions). Such approaches could provide improvements in health care delivery and clinical outcomes, especially in the field of heart failure. Major professional, policy, and ethical issues will have to be overcome to enable real-world implementation. This challenge may be relevant for the evolution of our health care systems

    Human Milk Protein Production in Xenografts of Genetically Engineered Bovine Mammary Epithelial Stem Cells

    Get PDF
    BACKGROUND: In the bovine species milk production is well known to correlate with mammary tissue mass. However, most advances in optimizing milk production relied on improvements of breeding and husbandry practices. A better understanding of the cells that generate bovine mammary tissue could facilitate important advances in milk production and have global economic impact. With this possibility in mind, we show that a mammary stem cell population can be functionally identified and isolated from the bovine mammary gland. We also demonstrate that this stem cell population may be a promising target for manipulating the composition of cow's milk using gene transfer. METHODS AND FINDINGS: We show that the in vitro colony-forming cell assay for detecting normal primitive bipotent and lineage-restricted human mammary clonogenic progenitors are applicable to bovine mammary cells. Similarly, the ability of normal human mammary stem cells to regenerate functional bilayered structures in collagen gels placed under the kidney capsule of immunodeficient mice is shared by a subset of bovine mammary cells that lack aldehyde dehydrogenase activity. We also find that this activity is a distinguishing feature of luminal-restricted bovine progenitors. The regenerated structures recapitulate the organization of bovine mammary tissue, and milk could be readily detected in these structures when they were assessed by immunohistochemical analysis. Transplantation of the bovine cells transduced with a lentivirus encoding human β-CASEIN led to expression of the transgene and secretion of the product by their progeny regenerated in vivo. CONCLUSIONS: These findings point to a common developmental hierarchy shared by human and bovine mammary glands, providing strong evidence of common mechanisms regulating the maintenance and differentiation of mammary stem cells from both species. These results highlight the potential of novel engineering and transplant strategies for a variety of commercial applications including the production of modified milk components for human consumption
    • …
    corecore