    Physiological based CPAP for preterm infants at birth

    Get PDF
    Preterm infants are currently supported with 5-8 cmH2O continuous positivie airway pressure (CPAP) at birth. This pressure range is predominantly extrapolated from CPAP support later on the neonatal intensive care unit, while the underlying physiology during the transition at birth is considarably different. Based on literature- and retrospective studies, we hyptothesized that preterm infants may benefit from physiological-based (PB)-CPAP, wherein CPAP levels change following the pulmonary physiological changes during transition. PB-CPAP consists of an initial 15 cmH2O CPAP that promotes lung aeration, but that is later decreased to 8 cmH2O CPAP to maintain lung aeration. In animal studies, we demonstrated that PB-CPAP improves lung aeration and decreases the risk of apnea, without causing lung over-expansion when CPAP levels are decreased appropriately. In a randomized trial, we showed that PB-CPAP improves heart rates of preterm infants when compared to 5-8 cmH2O, which also implies improved lung aeration. Despite its benefits, the current PB-CPAP strategy is too complex for caregivers to combine with standard care. Future studies will focus on automatization or simplification of PB-CPAP to improve CPAP support for preterm infants at birth. LUMC / Geneeskund

    Preliminary assessment of a biogas-based power plant from organic waste in the north Netherlands

    Get PDF
    Biogas is expected to play a crucial role in achieving the energy targets set by the European Union. Biogas, which mainly comprises methane and carbon dioxide, is produced in an anaerobic reactor, which transforms biomass into biogas. A consortium of anaerobic bacteria and archaea produces biogas during the anaerobic digestion (AD) of various types of feedstocks, such as animal slurries, energy crops, and agricultural residues. A biogas-fed gas turbine-generator and steam generator produce heat and power. In this study, a combined heat and power installation is studied. The biogas-based power plant treating cow manure, grass straw, and sugar beet pulp was examined using the software SuperPro Designer, and the obtained economic reports are evaluated. From the results, subsidy for electricity does not change the feasibility of the plants in case that cow manure or sugar beet pulp are used as feedstocks. The net present value (NPV) of biogas plants treating cow manure and sugar beet pulp was negative and the subsidy is not sufficient to make profitable these cases. The biogas power plant treating straw showed a positive net present value even without subsidy, which means that it is more desirable to invest in a plant that produces electricity and digestate from grass straw

    Feasibility and effect of physiological-based CPAP in preterm infants at birth

    Get PDF
    Background: Preterm infants are commonly supported with 5-8 cmH(2)O CPAP. However, animal studies demonstrate that high initial CPAP levels (12-15 cmH(2)O) which are then reduced (termed physiological based (PB)-CPAP), improve lung aeration without adversely affecting cardiovascular function. We investigated the feasibility of PB-CPAP and the effect in preterm infants at birth.Methods: Preterm infants (24-30 weeks gestation) were randomized to PB-CPAP or 5-8 cmH(2)O CPAP for the first 10 min after birth. PB-CPAP consisted of 15 cmH(2)O CPAP that was decreased when infants were stabilized (heart rate >= 100 bpm, SpO(2) >= 85%, FiO(2) <= 0.4, spontaneous breathing) to 8 cmH(2)O with steps of ~2/3 cmH(2)O/min. Primary outcomes were feasibility and SpO(2) in the first 5 min after birth. Secondary outcomes included physiological and breathing parameters and short-term neonatal outcomes. Planned enrollment was 42 infants.Results: The trial was stopped after enrolling 31 infants due to a low inclusion rate and recent changes in the local resuscitation guideline that conflict with the study protocol. Measurements were available for analysis in 28 infants (PB-CPAP n = 8, 5-8 cmH(2)O n = 20). Protocol deviations in the PB-CPAP group included one infant receiving 3 inflations with 15 cmH(2)O PEEP and two infants in which CPAP levels were decreased faster than described in the study protocol. In the 5-8 cmH(2)O CPAP group, three infants received 4, 10, and 12 cmH(2)O CPAP. During evaluations, caregivers indicated that the current PB-CPAP protocol was difficult to execute. The SpO(2) in the first 5 min after birth was not different [61 (49-70) vs. 64 (47-74), p = 0.973]. However, infants receiving PB-CPAP achieved higher heart rates [121 (111-130) vs. 97 (82-119) bpm, p = 0.016] and duration of mask ventilation was shorter [0:42 (0:34-2:22) vs. 2:58 (1:36-6:03) min, p = 0.020]. Infants in the PB-CPAP group required 6:36 (5:49-11:03) min to stabilize, compared to 9:57 (6:58-15:06) min in the 5-8 cmH2O CPAP group (p = 0.256). There were no differences in short-term outcomes.Conclusion: Stabilization of preterm infants with PB-CPAP is feasible but tailoring CPAP appeared challenging. PB-CPAP did not lead to higher SpO(2) but increased heart rate and shortened the duration of mask ventilation, which may reflect faster lung aeration.Developmen

    Repetitive versus standard tactile stimulation of preterm infants at birth - A randomized controlled trial

    Get PDF
    Development and application of statistical models for medical scientific researc

    Comparison of Two Respiratory Support Strategies for Stabilization of Very Preterm Infants at Birth: A Matched-Pairs Analysis

    Get PDF
    Objective: Respiratory support for stabilizing very preterm infants at birth varies between centers. We retrospectively compared two strategies that involved either increasing continuous positive airway pressures (CPAP), or increasing oxygen supplementation.Methods: Matched-pairs of infants (&lt;28 weeks of gestation) were born either at the Leiden University Medical Center [low-pressure: CPAP 5–8 cmH2O and/or positive pressure ventilation (PPV) and fraction of inspired oxygen (FiO2) 0.3–1.0; n = 27], or at the University Hospital of Cologne (high-pressure: CPAP 12–35 cmH2O, no PPV and FiO2 0.3–0.4; n = 27). Respiratory support was initiated non-invasively via facemask at both units. Infants (n = 54) were matched between centers for gestational age and birth weight, to compare physiological and short-term clinical outcomes.Results: In the low-pressure group, 20/27 (74%) infants received 1–2 sustained inflations (20, 25 cm H2O) and 22/27 (81%) received PPV (1:19–3:01 min) using pressures of 25–27 cm H2O. Within 3 min of birth [median (IQR)], mean airway pressures [12 (6–15) vs. 19 (16–23) cmH2O, p &lt; 0.001] and FiO2 [0.30 (0.28–0.31) vs. 0.22 (0.21–0.30), p &lt; 0.001] were different in low- vs. high-pressure groups, respectively. SpO2 and heart rates were similar. After 3 min, higher FiO2 levels [0.62 (0.35–0.98) vs. 0.28 (0.22–0.38), p = 0.005] produced higher SpO2 levels [77 (50–92) vs. 53 (42–69)%, p &lt; 0.001] in the low-pressure group, but SpO2/FiO2 and heart rates were similar. While intubation rates during admission were significantly different (70 vs. 30%, p = 0.013), pneumothorax rates (4 vs. 19%, p = 0.125) and the occurrence of spontaneous intestinal perforations (0 vs. 15%, p = 0.125) were similar between groups.Conclusion: Infants (&lt;28 weeks) can be supported non-invasively at birth with either higher or lower pressures and while higher-pressure support may require less oxygen, it does not eliminate the need for oxygen supplementation. Future studies need to examine the effect of high pressures and pressure titration in the delivery room

    Increasing Respiratory Effort With 100% Oxygen During Resuscitation of Preterm Rabbits at Birth

    Get PDF
    Background: Spontaneous breathing is essential for successful non-invasive respiratory support delivered by a facemask at birth. As hypoxia is a potent inhibitor of spontaneous breathing, initiating respiratory support with a high fraction of inspired O2 may reduce the risk of hypoxia and increase respiratory effort at birth. Methods: Preterm rabbit kittens (29 days gestation, term ~32 days) were delivered and randomized to receive continuous positive airway pressure with either 21% (n = 12) or 100% O2 (n = 8) via a facemask. If apnea occurred, intermittent positive pressure ventilation (iPPV) was applied with either 21% or 100% O2 in kittens who started in 21% O2, and remained at 100% O2 for kittens who started the experiment in 100% O2. Respiratory rate (breaths per minute, bpm) and variability in inter-breath interval (%) were measured from esophageal pressure recordings and functional residual capacity (FRC) was measured from synchrotron phase-contrast X-ray images. Results: Initially, kittens receiving 21% O2 had a significantly lower respiratory rate and higher variability in inter-breath interval, indicating a less stable breathing pattern than kittens starting in 100% O2 [median (IQR) respiratory rate: 16 (4–28) vs. 38 (29–46) bpm, p = 0.001; variability in inter-breath interval: 33.3% (17.2–50.1%) vs. 27.5% (18.6–36.3%), p = 0.009]. Apnea that required iPPV, was more frequently observed in kittens in whom resuscitation was started with 21% compared to 100% O2 (11/12 vs. 1/8, p = 0.001). After recovering from apnea, respiratory rate was significantly lower and variability in inter-breath interval was significantly higher in kittens who received iPPV with 21% compared to 100% O2. FRC was not different between study groups at both timepoints. Conclusion: Initiating resuscitation with 100% O2 resulted in increased respiratory activity and stability, thereby reducing the risk of apnea and need for iPPV after birth. Further studies in human preterm infants are mandatory to confirm the benefit of this approach in terms of oxygenation. In addition, the ability to avoid hyperoxia after initiation of resuscitation with 100% oxygen, using a titration protocol based on oxygen saturation, needs to be clarified

    The effect of initial oxygen exposure on diaphragm activity in preterm infants at birth

    Get PDF
    Background: The initial FiO(2) that should be used for the stabilization of preterm infants in the delivery room (DR) is still a matter of debate as both hypoxia and hyperoxia should be prevented. A recent randomized controlled trial showed that preterm infants [gestational age (GA) < 30 weeks] stabilized with an initial high FiO(2) (1.0) had a significantly higher breathing effort than infants stabilized with a low FiO(2) (0.3). As the diaphragm is the main respiratory muscle in these infants, we aimed to describe the effects of the initial FiO(2) on diaphragm activity.Methods: In a subgroup of infants from the original bi-center randomized controlled trial diaphragm activity was measured with transcutaneous electromyography of the diaphragm (dEMG), using three skin electrodes that were placed directly after birth. Diaphragm activity was compared in the first 5 min after birth. From the dEMG respiratory waveform several outcome measures were determined for comparison of the groups: average peak- and tonic inspiratory activity (dEMG(peak) and dEMG(ton), respectively), inspiratory amplitude (dEMG(amp)), area under the curve (dEMG(AUC)) and the respiratory rate (RR).Results: Thirty-one infants were included in this subgroup, of which 29 could be analyzed [n = 15 (median GA 28.4 weeks) and n = 14 (median GA 27.9 weeks) for the 100 and 30% oxygen group, respectively]. Tonic diaphragm activity was significantly higher in the high FiO(2)-group (4.3 +/- 2.1 mu V vs. 2.9 +/- 1.1 mu V; p = 0.047). The other dEMG-parameters (dEMG(peak), dEMG(amp), dEMG(AUC)) showed consistently higher values in the high FiO(2) group, but did not reach statistical significance. Average RR showed similar values in both groups (34 +/- 9 vs. 32 +/- 10 breaths/min for the high and low oxygen group, respectively).Conclusion: Preterm infants stabilized with an initial high FiO(2) showed significantly more tonic diaphragm activity and an overall trend toward a higher level of diaphragm activity than those stabilized with an initial low FiO(2). These results confirm that a high initial FiO(2) after birth stimulates breathing effort, which can be objectified with dEMG.Developmen

    High-CPAP does not impede cardiovascular changes at birth in preterm sheep

    Get PDF
    Objective: Continuous positive airway pressures (CPAP) used to assist preterm infants at birth are limited to 4-8 cmH(2)O due to concerns that high-CPAP may cause pulmonary overexpansion and adversely affect the cardiovascular system. We investigated the effects of high-CPAP on pulmonary (PBF) and cerebral (CBF) blood flows and jugular vein pressure (JVP) after birth in preterm lambs.Methods: Preterm lambs instrumented with flow probes and catheters were delivered at 133/146 days gestation. Lambs received low-CPAP (LCPAP: 5 cmH(2)O), high-CPAP (HCPAP: 15 cmH(2)O) or dynamic HCPAP (15 decreasing to 8 cmH(2)O at similar to 2 cmH(2)O/min) for up to 30 min after birth.Results: Mean PBF was lower in the LCPAP [median (Q1-Q3); 202 (48-277) mL/min, p = 0.002] compared to HCPAP [315 (221-365) mL/min] and dynamic HCPAP [327 (269-376) mL/min] lambs. CBF was similar in LCPAP [65 (37-78) mL/min], HCPAP [73 (41-106) mL/min], and dynamic HCPAP [66 (52-81) mL/min, p = 0.174] lambs. JVP was similar at CPAPs of 5 [8.0 (5.1-12.4) mmHg], 8 [9.4 (5.3-13.4) mmHg], and 15 cmH(2)O [8.6 (6.9-10.5) mmHg, p = 0.909]. Heart rate was lower in the LCPAP [134 (101-174) bpm; p = 0.028] compared to the HCPAP [173 (139-205)] and dynamic HCPAP [188 (161-207) bpm] groups. Ventilation or additional caffeine was required in 5/6 LCPAP, 1/6 HCPAP, and 5/7 dynamic HCPAP lambs (p = 0.082), whereas 3/6 LCPAP, but no HCPAP lambs required intubation (p = 0.041), and 1/6 LCPAP, but no HCPAP lambs developed a pneumothorax (p = 0.632).Conclusion: High-CPAP did not impede the increase in PBF at birth and supported preterm lambs without affecting CBF and JVP.Developmen

    Higher CPAP levels improve functional residual capacity at birth in preterm rabbits

    Get PDF
    BACKGROUND: Preterm infants are commonly supported with 4-8 cm H2O continuous positive airway pressures (CPAP), although higher CPAP levels may improve functional residual capacity (FRC).METHODS: Preterm rabbits delivered at 29/32 days (similar to 26-28 weeks human) gestation received 0, 5, 8, 12, 15 cm H2O of CPAP or variable CPAP of 15 to 5 or 15 to 8 cm H2O (decreasing similar to 2 cm H2O/min) for up to 10 min after birth.RESULTS: FRC was lower in the 0 (6.8 (1.0-11.2) mL/kg) and 5 (10.1 (1.1-16.8) mL/kg) compared to the 15 (18.8 (10.9-22.4) mL/kg) cm H2O groups (p = 0.003). Fewer kittens achieved FRC > 15 mL/kg in the 0 (20%), compared to 8 (36%), 12 (60%) and 15 (73%) cm H2O groups (p = 0.008). While breathing rates were not different (p = 0.096), apnoea tended to occur more often with CPAP < 8 cm H2O (p = 0.185). CPAP belly and lung bulging rates were similar whereas pneumothoraces were rare. Lowering CPAP from 15 to 5, but not 15 to 8 cm H2O, decreased FRC and breathing rates.CONCLUSION: In all, 15 cm H2O of CPAP improved lung aeration and reduced apnoea, but did not increase the risk of lung over-expansion, pneumothorax or CPAP belly immediately after birth. FRC and breathing rates were maintained when CPAP was decreased to 8 cm H2O.Developmen

    A gene expression atlas of the domestic pig

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>This work describes the first genome-wide analysis of the transcriptional landscape of the pig. A new porcine Affymetrix expression array was designed in order to provide comprehensive coverage of the known pig transcriptome. The new array was used to generate a genome-wide expression atlas of pig tissues derived from 62 tissue/cell types. These data were subjected to network correlation analysis and clustering.</p> <p>Results</p> <p>The analysis presented here provides a detailed functional clustering of the pig transcriptome where transcripts are grouped according to their expression pattern, so one can infer the function of an uncharacterized gene from the company it keeps and the locations in which it is expressed. We describe the overall transcriptional signatures present in the tissue atlas, where possible assigning those signatures to specific cell populations or pathways. In particular, we discuss the expression signatures associated with the gastrointestinal tract, an organ that was sampled at 15 sites along its length and whose biology in the pig is similar to human. We identify sets of genes that define specialized cellular compartments and region-specific digestive functions. Finally, we performed a network analysis of the transcription factors expressed in the gastrointestinal tract and demonstrate how they sub-divide into functional groups that may control cellular gastrointestinal development.</p> <p>Conclusions</p> <p>As an important livestock animal with a physiology that is more similar than mouse to man, we provide a major new resource for understanding gene expression with respect to the known physiology of mammalian tissues and cells. The data and analyses are available on the websites <url>http://biogps.org and http://www.macrophages.com/pig-atlas</url>.</p
    • …