3 research outputs found

    Performance characteristics of diagnostic assays for schistosomiasis in Ontario, Canada

    No full text
    Introduction: Due to lower intensity of infection and greater intervals from last exposure, parasitologic detection methods for schistosomiasis are poorly sensitive in non-endemic areas, challenging accurate diagnosis. Methods: We evaluated parasitologic versus indirect detection methods for schistosomiasis. We included specimens submitted for Schistosoma serology, and stool for ova and parasite microscopy. Three real-time PCR assays targeting Schistosoma mansoni and S. haematobium were performed. Primary outcome measures were sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV), where both microscopy and serology were the composite reference standard against serum PCR. Results: Of 8168 serum specimens submitted for Schistosoma serology, 638 (7.8%) were reactive and 6705 (82.1%) were non-reactive. Of 156,771 stool specimens submitted for ova and parasite testing, 46 (0.03%) were positive for eggs of S. mansoni . Four (0.5%) urine specimens were positive for eggs of S. haematobium . Combined serum PCRs targeting S. mansoni had a sensitivity and specificity of 27.8% (95% CI = 18.3–39.1%) and 100% (95% CI = 83.9–100%), respectively, with PPV of 100% (95% CI = 100%) and NPV of 26.9% (95% CI = 24.3–29.7%). The one serum sample positive for S. haematobium was also detectable by our S. haematobium PCR. No cross-reactivity was observed for all three PCR assays. Conclusions: Although serology is highly sensitive, parasitologic tests signify active infection, but are limited by low population-level sensitivity, particularly in non-endemic settings. Although serum PCR offered no performance advantage over stool microscopy, its role in diagnostic parasitology should be pursued due to its high-throughput and operator-independent nature

    Development and validation of a real-time PCR assay for the detection of clinical acanthamoebae

    No full text
    Background: Suboptimal agreement between molecular assays for the detection of Acanthamoeba spp. in clinical specimens has been demonstrated, and poor assay sensitivity directly imperils the vision of those affected by amoebic keratitis (AK) through delayed diagnosis. We sought to develop and validate a single Taqman real time PCR assay targeting the Acanthamoeba 18S rRNA gene that could be used to enhance sensitivity and specificity when paired with reference assays. Methods: Biobanked DNA from surplus delinked AK clinical specimens and 10 ATCC strains of Acanthamoeba was extracted. Sequence alignment of 66 18S rRNA regions from 12 species of Acanthamoeba known to cause keratitis informed design of a new TaqMan primer set. Performance of the new assay was compared to the 2 assays used currently in our laboratory. Results: Among 24 Acanthamoeba-positive and 83 negative specimens by the CDC reference standard, performance characteristics of the newly designed primer set were as follows: sensitivity 100%, specificity 94%, PPV 82.8%, and NPV 100%. Compared to culture, sensitivity of the new primer set was 100%, and specificity 96%. No cross-reactivity of the primer set to non-acanthamoebae, including Balamuthia and Naegleria, was found. Conclusions: We have validated a real time PCR assay for the diagnosis of AK, and in doing so, have overcome important barriers to rapid and sensitive detection of acanthamoebae, including limited sensitivity and specificity of commonly used assays.Medicine, Faculty ofNon UBCReviewedFacult
    corecore