168 research outputs found

    Neutron dosimetry, moderated energy spectrum, and neutron capture therapy for ²⁵{45}R²Cf medical sources

    Get PDF
    Examination of neutron dosimetry for 252Cf has been conducted using calculative and experimental means. Monte Carlo N-ParticIe (MCNP) transport code was used in a distributed computing environment as a parallel virtual machine (PVM) to determine the absorbed neutron dose and neutron energy spectrum from 252Cf in a variety of clinically relevant materials. Herein, a Maxwellian spectrum was used to model the 252Cf neutron emissions within these materials. 252Cf mixed-field dosimetry of Applicator Tube (AT) type sources was measured using 1.0 and 0.05 cm3 tissue-equivalent ion chambers and a miniature GM counter. A dosimetry protocol was formulated similar that of ICRU 45. The 252Cf AT neutron dosimetry was determined in the cylindrical coordinate system formalism recommended by the AAPM Task Group 43. These results demonstrated the overwhelming dependance of dosimetry on the source geometry factor as there was no significant neutron attenuation within the source or encapsulation. Gold foils and TLDs were used to measure the thermal flux in the vicinity of 252Cf AT sources to compare with the results calculated using MCNP. As the fast neutron energy spectrum did not markedly changed at increasing distances from the AT source, neutron dosimetry results obtained with paired ion chambers using fixed sensitivity factors agreed well with MCNP results and those in the literature. Calculations of moderated 252Cf neutron energy spectrum with various loadings of 10B and 157Gd were performed, in addition to analysis of neutron capture therapy dosimetry with these isotopes. Radiological concerns such as personnel exposure and shielding of 252Cf emissions were examined. Feasibility of a high specific-activity 252Cf HDR source was investigated through radiochemical and metallurgical studies using stand-ins such as Tb, Gd, and 249Cf. Issues such as capsule burst strength due to helium production for a variety of proposed HDR sources were addressed. A recommended 252Cf source strength of at least 1 mg was necessary for fabrication of a 252Cf HDR source

    The phylogeny of permanent prostate brachytherapy

    Get PDF
    Permanent prostate brachytherapy has been practiced for more than a century. This review examines the influence of earlier procedures on the modern transperineal ultrasound-directed technique. A literature review was conducted to examine the origin of current clinical practice. The dimensions of the modern brachytherapy seed, the prescription dose, and implant/teletherapy sequencing are vestigial features, which may be suboptimal in the current era of low-energy photon-emitting radionuclides and computerized dose calculations. Although the modern transperineal permanent prostate implant procedure has proven to be safe and effective, it should undergo continuous re-evaluation and evolution to ensure that its potential is maximized

    Definition of medical event is to be based on the total source strength for evaluation of permanent prostate brachytherapy: A report from the American Society for Radiation Oncology

    Get PDF
    AbstractPurposeThe Nuclear Regulatory Commission deems it to be a medical event (ME) if the total dose delivered differs from the prescribed dose by 20% or more. A dose-based definition of ME is not appropriate for permanent prostate brachytherapy as it generates too many spurious MEs and thereby creates unnecessary apprehension in patients, and ties up regulatory bodies and the licensees in unnecessary and burdensome investigations. A more suitable definition of ME is required for permanent prostate brachytherapy.Methods and MaterialsThe American Society for Radiation Oncology (ASTRO) formed a working group of experienced clinicians to review the literature, assess the validity of current regulations, and make specific recommendations about the definition of an ME in permanent prostate brachytherapy.ResultsThe working group found that the current definition of ME in §35.3045 as “the total dose delivered differs from the prescribed dose by 20 percent or more” was not suitable for permanent prostate brachytherapy since the prostate volume (and hence the resultant calculated prostate dose) is dependent on the timing of the imaging, the imaging modality used, the observer variability in prostate contouring, the planning margins used, inadequacies of brachytherapy treatment planning systems to calculate tissue doses, and seed migration within and outside the prostate. If a dose-based definition for permanent implants is applied strictly, many properly executed implants would be improperly classified as an ME leading to a detrimental effect on brachytherapy. The working group found that a source strength-based criterion, of >20% of source strength prescribed in the post-procedure written directive being implanted outside the planning target volume is more appropriate for defining ME in permanent prostate brachytherapy.ConclusionsASTRO recommends that the definition of ME for permanent prostate brachytherapy should not be dose based but should be based upon the source strength (air-kerma strength) administered

    The Effects of Text Message Reminder on Blood Donor Show Rate

    Get PDF
    Introduction: Declining blood collection endangers the blood supply at a time when the health care system is requiring an increasingly greater amount of blood products. Blood donation centers are challenged to recruit and develop first-time donors into reliable repeat donors, thereby ensuring a sufficient blood supply. Communication strategies such as e-mail reminders have been shown to be an effective communications tool to promote blood collection. Alternatively, Text Messaging has been shown effective in primary care and preventative medicine. Text messaging improved patient compliance with a schedule of vaccine dosing, as well as improving patient attendance at outpatient clinics. Additionally, text messaging reminders have been shown to be as effective as phone reminders in increasing patient attendance at outpatient appointments. Finally, text messaging has been shown to be useful for managing self-care such as smoking cessation, monitoring asthmatic symptoms, and diabetes control. We investigated whether offering the use a text message reminder to donors would increase attendance at donation events, demonstrating that text messaging can be an effective tool in maintaining a pool of blood donors.https://scholarworks.uvm.edu/comphp_gallery/1008/thumbnail.jp

    Can Agricultural Management Induced Changes in Soil Organic Carbon Be Detected Using Mid-Infrared Spectroscopy?

    Get PDF
    A major limitation to building credible soil carbon sequestration programs is the cost of measuring soil carbon change. Diffuse reflectance spectroscopy (DRS) is considered a viable low-cost alternative to traditional laboratory analysis of soil organic carbon (SOC). While numerous studies have shown that DRS can produce accurate and precise estimates of SOC across landscapes, whether DRS can detect subtle management induced changes in SOC at a given site has not been resolved. Here, we leverage archived soil samples from seven long-term research trials in the U.S. to test this question using mid infrared (MIR) spectroscopy coupled with the USDA-NRCS Kellogg Soil Survey Laboratory MIR spectral library. Overall, MIR-based estimates of SOC%, with samples scanned on a secondary instrument, were excellent with the root mean square error ranging from 0.10 to 0.33% across the seven sites. In all but two instances, the same statistically significant (p \u3c 0.10) management effect was found using both the lab-based SOC% and MIR estimated SOC% data. Despite some additional uncertainty, primarily in the form of bias, these results suggest that large existing MIR spectral libraries can be operationalized in other laboratories for successful carbon monitoring

    Prescription dose evaluation for APBI with noninvasive image-guided breast brachytherapy using equivalent uniform dose

    Get PDF
    ABSTRACT PURPOSE: Noninvasive image-guided breast brachytherapy (NIBB) is an attractive novel approach to deliver accelerated partial breast irradiation (APBI). Calculations of equivalent uniform dose (EUD) were performed to identify the appropriate APBI dose for this technique. METHODS AND MATERIALS: APBI plans were developed for 15 patients: five with threedimensional conformal APBI (3D-CRT), five with multi-lumen intracavitary balloons (m-IBB), and five simulating NIBB treatment. Prescription doses of 34.0 and 38.5 Gy were delivered in 10 fractions for m-IBB and 3D-CRT, respectively. Prescription doses ranging from 34.0 to 38.5 Gy were considered for NIBB. Dose-volume histogram data from all 3D-CRT, m-IBB, and NIBB plans were used to calculate the biologically effective EUD and corresponding EUD to the PTV_eval using the following equation: ). An a/b value of 4.6 Gy was assumed for breast tumor. EUD for varying NIBB prescription doses were compared with EUD values for the other APBI techniques. RESULTS: Mean PTV_eval volume was largest for 3D-CRT (372.9 cm 3 ) and was similar for NIBB and m-IBB (88.7 and 87.2 cm 3 , respectively). The EUD value obtained by prescribing 38.5 Gy with 3D-CRT APBI was 38.6 Gy. The EUD value of 34.0 Gy prescribed with m-IBB was 34.4 Gy. EUD values for NIBB ranged from 33.9 to 38.2 Gy for prescription doses ranging from 34.0 to 38.5 Gy. CONCLUSIONS: Using EUD calculations to compare APBI techniques and treatment doses, a prescription dose of 36.0 Gy in 10 fractions using NIBB has a comparable biologic equivalent dose to other established brachytherapy techniques.
    corecore