20 research outputs found

    The James Webb Space Telescope Mission

    Full text link
    Twenty-six years ago a small committee report, building on earlier studies, expounded a compelling and poetic vision for the future of astronomy, calling for an infrared-optimized space telescope with an aperture of at least 4m4m. With the support of their governments in the US, Europe, and Canada, 20,000 people realized that vision as the 6.5m6.5m James Webb Space Telescope. A generation of astronomers will celebrate their accomplishments for the life of the mission, potentially as long as 20 years, and beyond. This report and the scientific discoveries that follow are extended thank-you notes to the 20,000 team members. The telescope is working perfectly, with much better image quality than expected. In this and accompanying papers, we give a brief history, describe the observatory, outline its objectives and current observing program, and discuss the inventions and people who made it possible. We cite detailed reports on the design and the measured performance on orbit.Comment: Accepted by PASP for the special issue on The James Webb Space Telescope Overview, 29 pages, 4 figure

    Abord sciatique latéral médiofémoral (une autre voie d'abord pour le bloc du nerf sciatique)

    No full text
    TOULOUSE3-BU Santé-Centrale (315552105) / SudocPARIS-BIUM (751062103) / SudocSudocFranceF

    Epidemiology of epilepsy in rural Benin: prevalence, incidence, mortality, and follow-up.

    No full text
    International audiencePURPOSE: Epilepsy is a major clinical and social issue in Africa. This study was conducted to estimate the prevalence, incidence, mortality, and therapeutic outcome in rural Djidja in Benin. METHODS: This was a two-phase study with a cross-sectional phase and 18 months of follow-up. In the first phase, information was obtained using door-to-door surveys, reports from key informants, and medical sources. People were interviewed using a validated screening questionnaire for epilepsy in tropical regions. The diagnosis of epilepsy was confirmed by a neurologist. We used a capture-recapture method to estimate the number of people with epilepsy (PWE). PWE were followed every month for 18 months after the cross-sectional survey. We asked the health services, the general population, and village leaders in the study area to identify suspected cases of epilepsy occurring during the follow-up. New cases were updated every month after confirmation. Antiepileptic drugs were prescribed to PWE. KEY FINDINGS: We surveyed 11,668 subjects (male-to-female ratio 0.9) and identified 123 PWE, yielding a prevalence of 10.5 per 1,000 (95% confidence interval (CI) 8.8-12.6/1,000). Combining the three sources, we found 148 PWE and a prevalence of 12.7 per 1,000 (95% CI 10.7-14.9/1,000). After application of the capture-recapture method, the prevalence was estimated to be as high as 38.4 per 1,000 (95% CI 34.9-41.9/1,000). The cumulative incidence was 104.2 per 100,000 and the mean annual incidence was 69.4 per 100,000. The mean annual mortality was 20.8 per 1,000. After treatment, 45% of PWE had total seizure remission and 35% had a decrease in the number of seizures. SIGNIFICANCE: This study shows that door-to-door survey findings could be improved by using information from other sources. The follow-up suggests that epilepsy could be controlled. Continuous drug delivery and regular follow-up are key

    SARS-CoV-2 Diagnostic Tests: Algorithm and Field Evaluation From the Near Patient Testing to the Automated Diagnostic Platform

    No full text
    Introduction: Since the first wave of COVID-19 in Europe, new diagnostic tools using antigen detection and rapid molecular techniques have been developed. Our objective was to elaborate a diagnostic algorithm combining antigen rapid diagnostic tests, automated antigen dosing and rapid molecular tests and to assess its performance under routine conditions. Methods: An analytical performance evaluation of four antigen rapid tests, one automated antigen dosing and one molecular point-of-care test was performed on samples sent to our laboratory for a SARS-CoV-2 reverse transcription PCR. We then established a diagnostic algorithm by approaching median viral loads in target populations and evaluated the limit of detection of each test using the PCR cycle threshold values. A field performance evaluation including a clinical validation and a user-friendliness assessment was then conducted on the antigen rapid tests in point-of-care settings (general practitioners and emergency rooms) for outpatients who were symptomatic for <7 days. Automated antigen dosing was trialed for the screening of asymptomatic inpatients. Results: Our diagnostic algorithm proposed to test recently symptomatic patients using rapid antigen tests, asymptomatic patients using automated tests, and patients requiring immediate admission using molecular point-of-care tests. Accordingly, the conventional reverse transcription PCR was kept as a second line tool. In this setting, antigen rapid tests yielded an overall sensitivity of 83.3% (not significantly different between the four assays) while the use of automated antigen dosing would have spared 93.5% of asymptomatic inpatient screening PCRs. Conclusion: Using tests not considered the “gold standard” for COVID-19 diagnosis on well-defined target populations allowed for the optimization of their intrinsic performances, widening the scale of our testing arsenal while sparing molecular resources for more seriously ill patients.info:eu-repo/semantics/publishe

    Correction to: Biological tests carried out on serum/plasma samples from donors of human body material for transplantation: Belgian experience and practical recommendations

    No full text
    The article Biological tests carried out on serum/plasma samples from donors of human body material for transplantation: Belgian experience and practical recommendations. Erratum for Biological tests carried out on serum/plasma samples from donors of human body material for transplantation: Belgian experience and practical recommendations. [Cell Tissue Bank. 2018

    Biological tests carried out on serum/plasma samples from donors of human body material for transplantation: Belgian experience and practical recommendations

    No full text
    This paper on the biological tests carried out on serum/plasma samples from donors of human body material (HBM) is the result of a project of the working Group of Superior Health Council of Belgium formed with experts in the field of HBM and infectious serology. Indeed, uncertainty about the interpretation of biological test results currently leads to the sometimes unjustified cancelling of planned donations or the rejection of harvested HBM, whilst more sophisticated diagnostic algorithms would still allow the use of organs or HBM that would otherwise have been rejected. NAT tests will not be discussed in this publication. In the first part some general aspects as the need for a formal agreement between the Tissue Establishment l and the laboratory responsible for the biological testing, but also some specifications regarding testing material, the choice of additional biological tests, and some general aspects concerning interpretation and reporting are discussed. In a second part, detailed information and recommendations concerning the interpretation are presented for each of the mandatory tests (human immunodeficiency virus, hepatitis B virus, hepatitis C virus and syphilis) is presented. A number of not mandatory, but regularly used optional serological tests (e.g. for the detection of antibodies to Toxoplasma gondii, Epstein-Barr virus, human T cell leukemia virus and cytomegalovirus) are also extensively discussed. Although the project was meant to provide clarification and recommendations concerning the Belgian legislation, the majority of recommendations are also applicable to testing of donors of tissues and cells in other (European) countries.status: publishe
    corecore