2 research outputs found

    Radioiodine therapy of differentiated thyroid cancer: radiologic impact of out-patient treatment with 100 to 150 mCi Iodine-131 activities

    Get PDF
    OBJETIVO: Determinar exposições decorrentes da radioiodoterapia ambulatorial do carcinoma diferenciado da tireoide (CDT) sobre os familiares dos pacientes e o meio ambiente. MÉTODOS: Administraram-se 100 a 150 mCi de (131I)NaI para tratamento ambulatorial de 20 pacientes com CDT. Monitorizaram-se com dosímetros termoluminescentes as doses de radiação recebidas por familiares (n = 27) e potenciais de dose nas residências. Também foram monitorizadas contaminação de superfície e rejeitos radioativos. RESULTADOS: Registraram-se doses < 1,0 mSv em 26 acompanhantes e 2,8 mSv em um caso, inferiores ao aceitável para exposições médicas (5,0 mSv/procedimento). Excetuando-se o quarto dos pacientes (média = 0,69 mSv), determinou-se potencial de dose nas residências < 0,25 mSv. A contaminação de superfícies (4,2 Bq.cm-2) não ultrapassou níveis de liberação, sem representar riscos mesmo em simulações do pior cenário. Os rejeitos radioativos tiveram volume de 2,5 litros e atividade estimada em 90 µCi (média = 4,5 µCi/paciente). CONCLUSÕES: Não foi constatado impacto radiológico ao meio ambiente ou aos familiares de pacientes tratados ambulatorialmente com 100 a 150 mCi de iodo-131 e acompanhados por profissionais qualificados.PURPOSE:To evaluate exposure and dosimetry to family members and environment due to outpatient radioiodine therapy of differentiated thyroid carcinoma. METHODS: Twenty patients were treated with 100-150mCi of iodine-131 on an out-patient basis. Family members dosimetry (n = 27) and potential doses inside the house were measured with thermoluminescent dosimeters. Surface contamination and radioactive wastes were also monitored. RESULTS: Less than 1.0 mSv doses were found in 26 co-habitants and 2.8 mSv in a single case (inferior to the acceptable value of 5.0 mSv/procedure). Potential doses in the houses were inferior to 0.25 mSv, excluding the patients bedroom (mean value = 0.69 mSv). Surface contamination (mean = 4.2 Bq.cm-2) were below clearance levels. Radioactive wastes generated had a volume of 2.5 liters and a total activity estimated in 90 µCi, with a calculated exposure close to the background radiation levels. CONCLUSIONS: No radiological impact was detected after iodine therapy with 100-150 mCi on an out-patient basis followed by experienced professionals.Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP
    corecore