325 research outputs found

    A Framework for Design-Time Testing of Service-Based Applications at BPEL Level

    Get PDF
    Software applications created on top of the service-oriented architecture (SOA) are increasingly popular but testing them remains a challenge. In this paper a framework named TASSA for testing the functional and non-functional behaviour of service-based applications is presented. The paper focuses on the concept of design time testing, the corresponding testing approach and architectural integration of the consisting TASSA tools. The individual TASSA tools with sample validation scenarios were already presented with a general view of their relation. This paper’s contribution is the structured testing approach, based on the integral use of the tools and their architectural integration. The framework is based on SOA principles and is composable depending on user requirements.The work reported in this paper was supported by a research project funded by the National Scientific Fund, Bulgarian Ministry of Education, Youth and Science, via agreement no. DOO2-182

    Mössbauer study of nanodimensional nickel ferrite-mechanochemical synthesis and catalytic properties

    Get PDF
    Iron-nickel spinel oxide NiFe2O4 nanoparticles have been prepared by the combination of chemical precipitation and subsequent mechanical milling. For comparison, their analogue obtained by thermal synthesis is also studied. Phase composition and structural properties of iron-nickel oxides are investigated by X-ray diffraction and Mössbauer spectroscopy. Their catalytic behavior in methanol decomposition to CO and methane is tested. An influence of the preparation method on the reduction and catalytic properties of iron-nickel samples is established

    Characterization of nanodimensional Ni-Zn ferrite prepared by mechanochemical and thermal methods.

    Get PDF
    Nickel zinc ferrite nanoparticles, Ni1−xZnxFe2O4 (x = 0, 0.2, 0.5, 0.8, 1.0), with dimensions below 10 nm have been prepared by combining chemical precipitation with high-energy ball milling. For comparison, their analogues obtained by thermal synthesis have also been studied. Mössbauer spectroscopy, X-ray diffraction, and magnetic measurements are used for the characterization of the obtained materials. X-ray diffraction shows that after 3h of mechanical treatment ferrites containing zinc are formed, while 6h of treatment is needed to obtain NiFe2O4. The magnetic properties of the samples exhibit a strong dependence on the phase composition, particle size and preparation method

    Mössbauer and magnetic study of Co x Fe3−x O4 nanoparticles

    Get PDF
    Magnetic nanoparticles of cobalt ferrites Co x Fe3−x O4 (x = 1 or 2) have been obtained either by mechanical milling or thermal treatment of pre-prepared layered double hydroxide carbonate x-LDH–CO3. Mechanical milling of the 1-LDH–CO3 leads to the large-scale preparation of nearly spherical nanoparticles of CoFe2O4, the size of which (5 to 20 nm) is controlled by the treatment time. Core-shell structure with surface spin-canting has been considered for the nanoparticles formed to explain the observed hysteresis loop shift (from ZFC–FC) in the magnetic properties. Annealing treatment of the 2-LDH–CO3 below 673 K results in the formation of nearly spherical pure Co2FeO4 nanoparticles. At 673 K and above, the LDH decomposition leads to the formation of a mixture of both spinels phases Co2FeO4 and CoFe2O4, the amount of the latter increases with annealing temperature. Unusually high magnetic hardness characterized by a 22 kOe coercive field at 1.8 K has been observed, which reflects the high intrinsic anisotropy for Co2FeO4

    The Neuromelanin-related T2* Contrast in Postmortem Human Substantia Nigra with 7T MRI

    Get PDF
    High field magnetic resonance imaging (MRI)-based delineation of the substantia nigra (SN) and visualization of its inner cellular organization are promising methods for the evaluation of morphological changes associated with neurodegenerative diseases; however, corresponding MR contrasts must be matched and validated with quantitative histological information. Slices from two postmortem SN samples were imaged with a 7 Tesla (7T) MRI with T1 and T2* imaging protocols and then stained with Perl???s Prussian blue, Kluver-Barrera, tyrosine hydroxylase, and calbindin immunohistochemistry in a serial manner. The association between T2* values and quantitative histology was investigated with a co-registration method that accounts for histology slice preparation. The ventral T2* hypointense layers between the SNr and the crus cerebri extended anteriorly to the posterior part of the crus cerebri, which demonstrates the difficulty with an MRI-based delineation of the SN. We found that the paramagnetic hypointense areas within the dorsolateral SN corresponded to clusters of neuromelanin (NM). These NM-rich zones were distinct from the hypointense ventromedial regions with high iron pigments. Nigral T2* imaging at 7T can reflect the density of NM-containing neurons as the metal-bound NM macromolecules may decrease T2* values and cause hypointense signalling in T2* imaging at 7T.ope

    Feasibility of Using Ultra-High Field (7 T) MRI for Clinical Surgical Targeting

    Get PDF
    The advantages of ultra-high magnetic field (7 Tesla) MRI for basic science research and neuroscience applications have proven invaluable. Structural and functional MR images of the human brain acquired at 7 T exhibit rich information content with potential utility for clinical applications. However, (1) substantial increases in susceptibility artifacts, and (2) geometrical distortions at 7 T would be detrimental for stereotactic surgeries such as deep brain stimulation (DBS), which typically use 1.5 T images for surgical planning. Here, we explore whether these issues can be addressed, making feasible the use of 7 T MRI to guide surgical planning. Twelve patients with Parkinson's disease, candidates for DBS, were scanned on a standard clinical 1.5 T MRI and a 7 T MRI scanner. Qualitative and quantitative assessments of global and regional distortion were evaluated based on anatomical landmarks and transformation matrix values. Our analyses show that distances between identical landmarks on 1.5 T vs. 7 T, in the mid-brain region, were less than one voxel, indicating a successful co-registration between the 1.5 T and 7 T images under these specific imaging parameter sets. On regional analysis, the central part of the brain showed minimal distortion, while inferior and frontal areas exhibited larger distortion due to proximity to air-filled cavities. We conclude that 7 T MR images of the central brain regions have comparable distortions to that observed on a 1.5 T MRI, and that clinical applications targeting structures such as the STN, are feasible with information-rich 7 T imaging

    Exporting and labor demand : micro-level evidence from Germany

    Get PDF
    It is widely believed that globalization affcts the extent of employment and wage responses to economic shocks. To provide evidence for this, we analyze the effect of firms' exporting behavior on the elasticity of labor demand. Using rich, German administrative linked employer-employee panel data from 1996 to 2008, we explicitly control for self-selection into exporting and endogeneity concerns. In line with our theoretical model, we find that exporting at both the intensive and extensive margins significantly increases the (absolute value of the) unconditional own-wage labor demand elasticity. This is not only true for the average worker, but also for different skill groups. For the median firm, the elasticity is three-quarters higher when comparing exporting to nonexporting firms
    corecore