8 research outputs found

    <i>In vitro</i> testing of silicone elastomer encapsulated DST nano-T devices immersed in incubated SVF, showing the temperature responses subject to four different use schedules.

    No full text
    <p>In each case, the sampling interval was 8 min. A鈥攄evice maintained at 37掳C; B鈥攄evice removed from incubator at 96 h; C鈥攄evice removed and returned to incubator numerous times during a 12 h period; D鈥攄evice removed from incubator for progressively longer time periods before being returned.</p

    Statistical data for DST nano-T devices placed in various <i>in vitro</i> and <i>in vivo</i> environments.

    No full text
    <p><sup>#</sup> Data obtained from <a href="http://www.plosone.org/article/info:doi/10.1371/journal.pone.0125682#pone.0125682.g006" target="_blank">Fig 6A</a>.</p><p>Statistical data for DST nano-T devices placed in various <i>in vitro</i> and <i>in vivo</i> environments.</p

    Evaporative cooling effect following removal of the silicone elastomer encapsulated DST nano-T device from the macaque vagina.

    No full text
    <p>Temperatures recorded by the vaginal device drop immediately after removal and increase with time. The lower temperatures measured soon after removal are due to evaporation of PBS wash buffer from the encapsulated device. As the water evaporates, the measured temperature rises. To more fully appreciate the evaporative cooling phenomenon, the baseline laboratory data, which is relatively low due to remote location of the sensor, can be shifted to 22.3掳C.</p

    A鈥擠ST nano-T temperature logging device, as supplied; B鈥攊llustration of vaginal ring device with cavity for insertion of temperature logger.

    No full text
    <p>C鈥攃onstruction of temperature logging device encapsulated in silicone elastomer tubing for vaginal testing in macaques; C1 shows the silicone elastomer tubing (8.0 mm overall diameter); C2 shows the logger inserted into the silicone elastomer tubing; C3 shows the tubing end-sealed with silicone elastomer.</p

    <i>In vitro</i> testing of DST nano-T temperature logging devices using sampling rates of 8 and 60 min.

    No full text
    <p>Devices were placed in a shaking orbital incubator set to 37掳C, removed from the incubator at 120 min, returned to the incubator at 240 min, and then finally removed at 360 min. A鈥攄evices as supplied, i.e. non-encapsulated. B鈥攄evices sealed in silicone elastomer tubing. C鈥攄evices sealed in silicone elastomer tubing and placed in 10 mL of simulated vaginal fluid contained in a glass beaker.</p

    Temperature response versus time for vaginally and subcutaneously administered temperature loggers in cynomolgus macaques.

    No full text
    <p>Each graph shows a representative plot for a single macaque. Solid and dashed arrows indicate removal and re-insertion of the vaginal device, respectively. Laboratory temperature as measured by a control temperature logging device is indicated by the dashed line at ~22掳C. A鈥攙aginal device worn continuously over a 7-day period. B鈥攙aginal device removed after 3 days placement. C鈥攙aginal device removed and reinserted on three different occasions during the 7-day period.</p

    Effect of silicone elastomer sheath thickness on the <i>in vitro</i> temperature responsiveness of encapsulated DST nano-T devices in SVF.

    No full text
    <p>A鈥擣our removals and re-insertions were performed. The removal periods were 20, 30, 30 and 40 min. Temperature was recorded at 20 sec intervals; data points are not shown for sake of clarity. B鈥擬agnified view of the first removal and re-insertion period, showing the cooling and heating trends as a function of sheath thickness.</p