6 research outputs found

    Volume reduction of water samples to increase sensitivity for radioassay of lead contamination

    Get PDF
    The World Health Organisation (WHO) presents an upper limit for lead in drinking water of 10 parts per billion ppb. Typically, to reach this level of sensitivity, expensive metrology is required. To increase the sensitivity range of low-cost devices, this paper explores the prospects of using a volume reduction technique of a boiled water sample doped with Lead-210 (210 Pb), as a means to increase the solute’s concentration. 210Pb is a radioactive lead isotope and its concentration in a water sample can be measured with e.g. High Purity Germanium (HPGe) detectors at the Boulby Underground Germanium Suite. Concentrations close to the WHO limit have not been examined. This paper presents a measurement of the volume reduction technique retaining 99±(9)% of 210Pb starting from a concentration of 1.9×10−6 ppb before reduction and resulting in 2.63×10−4 ppb after reduction. This work also applies the volume reduction technique to London tap water and reports the radioassay results from gamma counting in HPGe detectors. Among other radio-isotopes, 40K, 210Pb, 131I and 177Lu were identified at measured concentrations of 2.83×103 ppb, 2.55×10−7 ppb, 5.06×10−10 ppb and 5.84×10−10 ppb in the London tap water sample. This technique retained 90±50% of 40K. Stable lead was inferred from the same water sample at a measured concentration of 0.012 ppb, prior to reduction

    Characterization of germanium detectors for the first underground laboratory in Mexico

    Get PDF
    This article reports the characterization of two High Purity Germanium detectors performed by extracting and comparing their efficiencies using experimental data and Monte Carlo simulations. The efficiencies were calculated for pointlike Îł-ray sources as well as for extended calibration sources. Characteristics of the detectors such as energy linearity, energy resolution and full energy peak efficiencies are reported from measurements performed on surface laboratories. The detectors will be deployed in a Îł-ray assay facility that will be located in the first underground laboratory in Mexico, Laboratorio Subterr'aneo de Mineral del Chico (LABChico), in the Comarca Minera UNESCO Global Geopark [1]

    Dosimetry and calorimetry performance of a scientific CMOS camera for environmental monitoring

    Get PDF
    This paper explores the prospect of CMOS devices to assay lead in drinking water, using calorimetry. Lead occurs together with traces of radioisotopes, e.g.,210 Pb, producing Îł-emissions with energies ranging from 10 keV to several 100 keV when they decay; this range is detectable in silicon sensors. In this paper we test a CMOS camera (OXFORD INSTRUMENTS Neo 5.5) for its general performance as a detector of X-rays and low energy Îł-rays and assess its sensitivity relative to the World Health Organization upper limit on lead in drinking water. Energies from 6 keV to 60 keV are examined. The CMOS camera has a linear energy response over this range and its energy resolution is for the most part slightly better than 2%. The Neo sCMOS is not sensitive to X-rays with energies below ∌ 10 keV. The smallest detectable rate is 40 ± 3 mHz, corresponding to an incident activity on the chip of 7 ± 4 Bq. The estimation of the incident activity sensitivity from the detected activity relies on geometric acceptance and the measured efficiency vs. energy. We report the efficiency measurement, which is 0.08(2)% (0.0011(2)%) at 26.3 keV (59.5 keV). Taking calorimetric information into account we measure a minimal detectable rate of 4 ± 1 mHz (1.5 ± 0.1 mHz) for 26.3 keV (59.5 keV) Îł-rays, which corresponds to an incident activity of 1.0 ± 0.6 Bq (57 ± 33 Bq). Toy Monte Carlo and Geant4 simulations agree with these results. These results show this CMOS sensor is well-suited as a Îł-and X-ray detector with sensitivity at the few to 100 ppb level for210 Pb in a sample
    corecore