208 research outputs found

    Evidence for narrow resonant structures at W1.68W \approx 1.68 and W1.72W \approx 1.72 GeV in real Compton scattering off the proton

    Get PDF
    First measurement of the beam asymmetry Σ\Sigma for Compton scattering off the proton in the energy range Eγ=0.851.25E_{\gamma}=0.85 - 1.25 GeV is presented. The data reveals two narrow structures at Eγ=1.036E_{\gamma}= 1.036 and Eγ=1.119E_{\gamma}=1.119 GeV. They may signal narrow resonances with masses near 1.681.68 and 1.721.72 GeV, or they may be generated by the sub-threshold KΛK\Lambda and ωp\omega p production. Their decisive identification requires additional theoretical and experimental efforts.Comment: Published versio

    Optimization of the gas flow in a GEM chamber and development of the GEM foil stretcher

    Get PDF
    The gas electron multiplier technology has been proven to tolerate rat e larger than 50 MHz/cm2 without noticeable aging and to provide sub resolution on working chambers up to 45 cm x 45 cm. A new gas electron multiplier-based tracker is under development for the Hall A upgrade at Jefferson Lab. The chambers of the tracker have been designed in a modular way: each chamber consists of 3 adjacent gas electron multiplier modules, with an active area of 40 cm x 50 cm each. We optimized the gas flow inside the gas electron multiplier module volume, using the COMSOL physics simulator framework; the COMSOL-based analysis includes the design of the inlet and outlet pipes and the maximization of the uniformity of the gas flow. We have defined the procedures for the assembling of the gas electron multiplier modules and designed a mechanical system (TENDIGEM) that will be used to stretch the GEM foils at the proper tension (few kg/cm); the TENDIGEM is based on the original design developed at LNF

    Comparison between direct measurements and indirect estimations of hydraulic conductivity for slope deposits of the North-Western Tuscany, Italy

    Get PDF
    Hydraulic conductivity (K) is a relevant engineering geology property of deposits that cover the geological bedrock (Slope Deposits – SD). This parameter is useful for many applications fields such as: simulations of both infiltration and runoff processes, hillslope stability numerical analysis, hydrological studies, soil science and environmental problems. A wide range of methods are available in the literature in order to estimate K. Anyhow, they can be divided into direct measurement (field and laboratory test) and indirect estimations (eg. correlation from grain size, pedotransfer functions). However, many factors (eg. SD grain size, bulk density, organic matter, etc.) can affect the K value hence the determination of K within SD is often a challenge. Moreover, the value of K generally shows an high spatial variability requiring a large number of direct measurements to obtain robust spatial estimations. Indirect methods may be used alternatively or in pair with direct methods. However, relations between K and other soil physical properties are generally suitable only for specific type of soils, therefore, the application of those relations are constrained. In this work a wide (about 200) set of field measurements were performed in North-Western Tuscany in order to assess the variability of K in the vadose zone for SD characterized by different grain size composition. Measurements were carried out by means of both constant and falling head permeameters, as well as double ring infiltrometer. In the test sites engineering geology properties of SD such as bulk density and depth have been collected, moreover, samples have been collected for laboratory analysis. A statistical analysis of the K value has been performed for SD characterized by different grain size distribution and geological bedrock. Moreover, a comparison between the field methods have been also performed. Finally, a comparison between measured and estimated values of K has been done in order to assess the reliability of different equations to predict K. The results show that the K value varies across: different geological settings, the SD profile and the geographic neighborhood of the test site. Moreover, the results highlight that the indirect methods used in this work have to be used carefully in our study area

    Evidence for Narrow N*(1685) Resonance in Quasifree Compton Scattering on the Neutron

    Full text link
    The first study of quasi-free Compton scattering on the neutron in the energy range of Eγ=0.751.5E_{\gamma}=0.75 - 1.5 GeV is presented. The data reveals a narrow peak at W1.685W\sim 1.685 GeV. This result, being considered in conjunction with the recent evidence for a narrow structure at W1.68W\sim 1.68GeV in the η\eta photoproduction on the neutron, suggests the existence of a new nucleon resonance with unusual properties: the mass M1.685M\sim 1.685GeV, the narrow width Γ30\Gamma \leq 30MeV, and the much stronger photoexcitation on the neutron than on the proton.Comment: Replaced with the version published in Phys. Rev.

    Donor Lymphocyte Infusions After Allogeneic Stem Cell Transplantation in Acute Leukemia: A Survey From the Gruppo Italiano Trapianto Midollo Osseo (GITMO)

    Get PDF
    We conducted a retrospective multicenter study including pediatric and adult patients with acute leukemia (AL) who received donor lymphocyte infusions (DLIs) after allogeneic hematopoietic stem cell transplantation (HCT) between January 1, 2010 and December 31, 2015, in order to determine the efficacy and toxicity of the immune treatment. Two hundred fifty-two patients, median age 45.1 years (1.6\u201373.4), were enrolled from 34 Italian transplant centers. The underlying disease was acute myeloid leukemia in 180 cases (71%). Donors were HLA identical or 1 locus mismatched sibling (40%), unrelated (40%), or haploidentical (20%). The first DLI was administered at a median time of 258 days (55\u20133,784) after HCT. The main indication for DLI was leukemia relapse (73%), followed by mixed chimerism (17%), and pre-emptive/prophylactic use (10%). Ninety-six patients (38%) received one single infusion, whereas 65 (26%), 42 (17%), and 49 patients (19%) received 2, 3, or 654 infusions, respectively, with a median of 31 days between two subsequent DLIs. Forty percent of evaluable patients received no treatment before the first DLI, whereas radiotherapy, conventional chemotherapy or targeted treatments were administered in 3, 39, and 18%, respectively. In informative patients, a few severe adverse events were reported: grade III\u2013IV graft versus host disease (GVHD) (3%), grade III\u2013IV hematological toxicity (11%), and DLI-related mortality (9%). Forty-six patients (18%) received a second HCT after a median of 232 days (32\u20131,390) from the first DLI. With a median follow-up of 461 days (2\u20133,255) after the first DLI, 1-, 3-, and 5- year overall survival (OS) of the whole group from start of DLI treatment was 55, 39, and 33%, respectively. In multivariate analysis, older recipient age, and transplants from haploidentical donors significantly reduced OS, whereas DLI for mixed chimerism or as pre-emptive/prophylactic treatment compared to DLI for AL relapse and a schedule including more than one DLI significantly prolonged OS. This GITMO survey confirms that DLI administration in absence of overt hematological relapse and multiple infusions are associated with a favorable outcome in AL patients. DLI from haploidentical donors had a poor outcome and may represent an area of further investigation

    A new limit on the light speed isotropy from the GRAAL experiment at the ESRF

    Full text link
    When the electrons stored in the ring of the European Synchrotron Radiation Facility (ESRF, Grenoble) scatter on a laser beam (Compton scattering in flight) the lower energy of the scattered electron spectra, the Compton Edge (CE), is given by the two body photon-electron relativistic kinematics and depends on the velocity of light. A precision measurement of the position of this CE as a function of the daily variations of the direction of the electron beam in an absolute reference frame provides a one-way test of Relativistic Kinematics and the isotropy of the velocity of light. The results of GRAAL-ESRF measurements improve the previously existing one-way limits, thus showing the efficiency of this method and the interest of further studies in this direction.Comment: Proceed. MG12 meeting, Paris, July, 200
    corecore