10 research outputs found

    Autonomous Navigation of Multiple Unmanned Aerial Vehicles

    No full text
    The focus of the present thesis is on the analysis and design of guidance, control and navigation algorithms for unmanned aerial vehicles, specifi cally in the context of drone warfare and aerospace battles. In aerospace engagement scenarios involving autonomous agents, the synthesis of intelligent actions must consider the potential strategies by the adversary. When analysing the possible outcomes of an engagement, unpredictability of the adversary's decisions presents the main challenge, the design of our strategies must be robust to a very broad set of possible counter strategies employed by the adversary. Differential game theory provides the correct framework to analyse and design optimal strategies in these dynamic engagement scenarios. Here the goal is the nd the state-feedback Nash equilibrium, the optimal outcome of an engagement scenario, in which all parties with knowledge of the strategies deployed, cannot increase their payoff by altering their decision making process. The contents of this thesis uncovers signi ficant new results in the area of pursuit-evasion differential games. The main contributions are, the discovery of a new geometric mechanism to verify the Hamilton-Jacobi-Bellman equations, and uncovering new symmetries in simple- motion pursuit-evasion games. More specifi cally, the thesis primarily examines the differential game of active target de- fence, otherwise known as the Target-Attacker-Defender pursuit-evasion game. This simple- motion, two-team, zero-sum differential game emulates a common aerospace engagement scenario found in defence applications. Here an explosive carrying Attacker is tasked with neutralising a Target, and the Target in its defence launches an agent named the Defender, from another platform in an integrated/fused air defence. The present thesis identi fies and proves the value and optimal state-feedback strategies for both teams in this engagement scenario. This is done via the analysis of the discrete- time turn-based variant of the differential game, also known as the upper or lower value. Moreover, we unearth new symmetries in the differential game, named Target Symmetry and Defender Symmetry. A symmetry is a transformation of the state of the differential game that leaves the optimal strategies unchanged. Using the newly discovered symmetries we develop unifi ed optimality principles, culminating in the Holographic Theorem for the differential game of active target defence, and more generally, the Holographic Principle for simple-motion differential games.Thesis (Ph.D.) -- University of Adelaide, School of Electrical and Mechanical Engineering, 202

    Fibrin sheaths in central venous port catheters: treatment with low-dose, single injection of urokinase on an outpatient basis

    No full text
    Purpose: Evaluation of the efficacy of single-shot, low-dose urokinase administration for the treatment of port catheter-associated fibrin sheaths. Methods: Forty-six patients were retrospectively evaluated for 54 episodes of port catheter dysfunction. The presence of a fibrin sheath was detected by angiographic contrast examinations. On an outpatient basis, patients subsequently received thrombolysis consisting of a single injection of urokinase (15.000 IU in 1.5 mL normal saline) through the port system. A second attempt was made in cases of treatment failure. Patients were followed up for technical success, complications and long-term outcome. Results: Port dysfunction occurred at a median of 117 days after implantation (range: 7-825 days). The technical success after first port dysfunction by thrombolysis was 87% (40/46); thereof, initial thrombolysis was effective in 78% (36/46). Nine patients (20%) received a second dose of urokinase after previous treatment failure. Follow-up was available for 26 of 40 patients after successful thrombolysis. In 8 of these, rethrombosis occurred after a median of 98 days (range: 21-354 days), whereby rethrombolysis was effective in 5 of 7 (63%) patients. The overall success of all thrombolyses performed was 70% (45/64). No procedure-related technical or clinical complications occurred. After first favorable thrombolysis, a Kaplan-Meier analysis yielded a 30-, 90- and 180-day probability of patency of 96%, 87% and 81%. Conclusion: Thrombolytic therapy on an outpatient basis appears to be a safe and efficient. Three-month patency rates are comparable to more invasive treatment options, including catheter exchange over a guide wire and percutaneous fibrin sheath stripping

    Implementation of ultra-low-dose lung protocols in CT-guided lung biopsies: feasibility and safety in the clinical setting

    No full text
    Objective: To evaluate the use of ultra-low-dose computed tomography (ULDCT) for CT-guided lung biopsy versus standard-dose CT (SDCT). Methods: CT-guided lung biopsies from 115 patients (50 ULDCT, 65 SDCT) were analyzed retrospectively. SDCT settings were 120 kVp with automatic mAs modulation. ULDCT settings were 80 kVp with fixed exposure (20 mAs). Two radiologists evaluated image quality (i.e., needle artifacts, lesion contouring, vessel recognition, visibility of interlobar fissures). Complications and histological results were also evaluated. Results: ULDCT was considered feasible for all lung interventions, showing the same diagnostic accuracy as SDCT. Its mean total radiation dose (dose-length product) was significantly reduced to 34 mGy-cm (SDCT 426 mGy-cm). Image quality and complication rates (P = 0.469) were consistent. Conclusions: ULDCT for CT-guided lung biopsies appears safe and accurate, with a significantly reduced radiation dose. We therefore recommend routine clinical use of ULDCT for the benefit of patients and interventionalists

    Long-Term Follow-Up and Clinical Relevance of Incidental Findings of Fibrin Sheath and Thrombosis on Computed Tomography Scans of Cancer Patients with Port Catheters

    No full text
    Purpose: This retrospective study examined the incidence, progression, and clinical relevance of catheter-related thrombosis (CRT) and/or fibrin sheaths presenting as incidental findings on routine staging computed tomography (CT) scans performed in cancer patients. Patients and Methods: Patients who underwent central venous port catheter (CVC) placement in a tertiary care hospital between September 2010 and August 2013 were followed up for up to five years. Two radiologists assessed the presence of fibrin sheath and thrombosis in consensus in staging CT scan. Patient demographics, type of cancer, preoperative comorbidities, date of CVC placement and CTs, preexisting anticoagulation, as well as the type and treatment of catheter-related complications were determined from the electronic medical record. Results: A total of 194 patients with 530 CT scans and a mean follow-up time of 394 days were included. Fibrin sheaths and thromboses were seen on 46 scans (8.7%) in 30 patients and 80 scans (15.1%) in 35 patients. The incidence of fibrin sheaths and thromboses was found to be 15.5% and 18%, respectively. The comparison to initial CT reports results indicated that fibrin sheaths or thromboses were missed in 106 examinations (20%). Catheter-associated complications were reported in 14 patients (21.5%) without specific therapy. Conclusion: Fibrin sheaths and CRTs are often overlooked on routine CT scans when patients are asymptomatic. The subsequent high complication rate demonstrates the clinical relevance of the initial incidental finding on CT scan. Further studies should elucidate the effect of thrombolytic agents and interventional radiologic treatment in asymptomatic patients

    Low-dose computed tomography of urolithiasis in obese patients: a feasibility study to evaluate image reconstruction algorithms

    No full text
    Purpose: Retrospective evaluation and comparison of image quality generated by low-dose computed tomography (LDCT) from obese patients with urolithiasis using alternative reconstruction algorithms. Materials and methods: Twenty-five obese patients (body mass index [BMI]>25 kg/m(2)) underwent LDCT scans for suspected urolithiasis. The scans were recompiled using filtered-back projection (FBP), statistical iterative reconstruction (iDose) and iterative model-based reconstruction (IMR). Dose-length product (DLP) and patient details were obtained from the CT dose report and clinical charts, respectively. Objective image noise was assessed by measuring the SD of Hounsfield units (HUs) in defined locations. Additionally, subjective image evaluation was independently performed by two radiologists using a 3-point Likert scale. The inter-reviewer agreement of image quality was calculated. Results: Ureteral concretions were observed in all CT scans, two of which revealed bilateral stones. The assessed patients' mean BMI was 29.29 +/- 3.74 kg/m(2), and the DLP of the CT scans was 100.04 +/- 10.00 mGy*cm. All scans were rated diagnostic with the iDose and iterative model-based reconstructions, whereas 41% of the scans performed with FBP reconstruction were nondiagnostic. With respect to image quality, IMR was superior to iDose and FBP, both in the objective (P<0.001) and overall subjective (P <= 0.008) evaluation of the respective data sets. The inter-reviewer agreement for overall image quality was almost perfect for IMR, substantial for iDose and moderate for FBP (kappa values of 1.0, 0.6 and 0.46, respectively). Conclusion: Using iterative image reconstruction algorithms, LDCT of urolithiasis is feasible in overweight patients with a BMI between 25 and 35 kg/m(2). Due to higher image quality, IMR is the preferred algorithm for scan reconstruction as it may help to avoid repeated examinations due to initial nondiagnostic scans

    Whole-body computed tomography in trauma patients: optimization of the patient scanning position significantly shortens examination time while maintaining diagnostic image quality

    No full text
    Background: The study was conducted to compare examination time and artifact vulnerability of whole-body computed tomographies (wbCTs) for trauma patients using conventional or optimized patient positioning. Patients and methods: Examination time was measured in 100 patients scanned with conventional protocol (Group A: arms positioned alongside the body for head and neck imaging and over the head for trunk imaging) and 100 patients scanned with optimized protocol (Group B: arms flexed on a chest pillow without repositioning). Additionally, influence of two different scanning protocols on image quality in the most relevant body regions was assessed by two blinded readers. Results: Total wbCT duration was about 35% or 3: 46 min shorter in B than in A. Artifacts in aorta (27 vs 6%), liver (40 vs 8%) and spleen (27 vs 5%) occurred significantly more often in B than in A. No incident of non-diagnostic image quality was reported, and no significant differences for lungs and spine were found. Conclusion: An optimized wbCT positioning protocol for trauma patients allows a significant reduction of examination time while still maintaining diagnostic image quality

    Implantation of venous access devices under local anesthesia: patients' satisfaction with oral lorazepam

    No full text
    Objective: The aim of the study reported here was to evaluate patients' satisfaction with implantation of venous access devices under local anesthesia (LA) with and without additional oral sedation. Materials and methods: A total of 77 patients were enrolled in the prospective descriptive study over a period of 6 months. Subcutaneous implantable venous access devices through the subclavian vein were routinely implanted under LA. Patients were offered an additional oral sedative (lorazepam) before each procedure. The level of anxiety/tension, the intensity of pain, and patients' satisfaction were evaluated before and immediately after the procedure using a visual analog scale (ranging from 0 to 10) with a standardized questionnaire. Results: Patients' satisfaction with the procedure was high (mean: 1.3 +/- 2.0) with no significant difference between the group with premedication and the group with LA alone (P=0.54). However, seven out of 30 patients (23.3%) in the group that received premedication would not undergo the same procedure without general anesthesia. There was no significant influence of lorazepam on the intensity of pain (P=0.88). In 12 out of 30 patients (40%) in the premedication group, the level of tension was higher than 5 on the visual analog scale during the procedure. In 21 out of 77 patients (27.3%), the estimate of the level of tension differed between the interventionist and the patient by 3 or more points in 21 out of 77 patients (27.3%). Conclusion: Overall patient satisfaction is high for implantation of venous access devices under LA. A combination of LA with lorazepam administered orally might not be adequate for patients with a high level of anxiety and tension. The level of tension is often underestimated by the interventionist. Pre-procedural standardized questionnaires could be used to identify patients for whom a gradual approach of individualized sedation may be more effective

    Modification of optical properties of PC-PBT/Cr 2

    No full text
    Nanocomposite (NCP) films of polycarbonate-polybutylene terephthalate (PC-PBT) blend as a host material to Cr2O3 and CdS nanoparticles (NPs) were fabricated by both thermolysis and casting techniques. Samples from the PC-PBT/Cr2O3 and PC-PBT/CdS NCPs were irradiated using different doses (20–110 kGy) of γ radiation. The induced modifications in the optical properties of the γ irradiated NCPs have been studied as a function of γ dose using UV Vis spectroscopy and CIE color difference method. Optical dielectric loss and Tauc's model were used to estimate the optical band gaps of the NCP films and to identify the types of electronic transition. The value of optical band gap energy of PC-PBT/Cr2O3 NCP was reduced from 3.23 to 3.06 upon γ irradiation up to 110 kGy, while it decreased from 4.26 to 4.14 eV for PC-PBT/CdS NCP, indicating the growth of disordered phase in both NCPs. This was accompanied by a rise in the refractive index for both the PC-PBT/Cr2O3 and PC-PBT/CdS NCP films, leading to an enhancement in their isotropic nature. The Cr2O3 NPs were found to be more effective in changing the band gap energy and refractive index due to the presence of excess oxygen atoms that help with the oxygen atoms of the carbonyl group in increasing the chance of covalent bonds formation between the NPs and the PC-PBT blend. Moreover, the color intensity, ΔE has been computed; results show that both the two synthesized NCPs have a response to color alteration by γ irradiation, but the PC-PBT/Cr2O3 has a more response since the values of ΔE achieved a significant color difference >5 which is an acceptable match in commercial reproduction on printing presses. According to the resulting enhancement in the optical characteristics of the developed NCPs, they can be a suitable candidate as activate materials in optoelectronic devices, or shielding sheets for solar cells
    corecore