28 research outputs found

    Global versus regional myocardial ischaemia: differences incardiovascular and sympathetic responses in cats

    No full text
    The cardiovascular and sympathetic responses to occlusions of the left main ("global" ischaemia) or distal left anterior descending ("regional" ischaemia) coronary artery were studied in 19 anaesthetised cats with chronic sinoaortic baroreceptor denervation. "Global" ischaemia, before vagotomy, resulted in a significant reduction of mean arterial pressure (MAP), left ventricular pressure (LVP), and LVdP/dtmax while sympathetic efferent impulse activity was significantly augmented during the initial 15 +/- 2 s of occlusion (early phase) and, vice versa inhibited during the subsequent 20 +/- 2 s of occlusion (late phase). Vagotomy did not modify the haemodynamic responses, however, a significant increase in sympathetic discharge was detectable during the whole occlusion period (early and late phases). "Regional" ischaemia, before vagotomy, resulted in a significant increase in sympathetic neural discharge and MAP, with no changes in left ventricular function. After vagotomy the occlusion elicited a significant increase in MAP, LVP, LVdP/dtmax and efferent sympathetic neural activity. These excitatory responses were abolished after the interruption of a large part of the cardiac sympathetic afferents. Thus coronary artery occlusion induced haemodynamic and sympathetic reflex responses that were dependent upon the interaction of opposite influences mediated by the simultaneous activation of cardiac vagal and sympathetic afferents. The extent of "ischaemic myocardium" represented a determinant factor for the prevailing type of neural response

    Continuous recording of direct high fidelity arterial pressure and electrocardiogram in ambulant patients

    No full text
    A system providing high quality direct arterial blood pressure recordings and electrocardiograms in ambulatory patients was devised using a modified commercially available Holter type magnetic tape recorder together with a microminiature Millar (3F) tip transducer. This system did not require a perfusion line and solved the major drawbacks of other available systems. Pressure and electrocardiographic data were fed directly from the playback unit into a minicomputer for automatic beat to beat waveform analysis. Thus the blood pressure and RR interval variability signals could be simultaneously analysed with autoregressive modelling techniques to provide a quantitative estimate of sympathovagal balance in ambulant patients. The system was reliable, simple, and safe to use
    corecore