6 research outputs found
Safety and Efficacy of a Dapivirine Vaginal Ring for HIV Prevention in Women.
BACKGROUND: The incidence of human immunodeficiency virus (HIV) infection remains high among women in sub-Saharan Africa. We evaluated the safety and efficacy of extended use of a vaginal ring containing dapivirine for the prevention of HIV infection in 1959 healthy, sexually active women, 18 to 45 years of age, from seven communities in South Africa and Uganda. METHODS: In this randomized, double-blind, placebo-controlled, phase 3 trial, we randomly assigned participants in a 2:1 ratio to receive vaginal rings containing either 25 mg of dapivirine or placebo. Participants inserted the rings themselves every 4 weeks for up to 24 months. The primary efficacy end point was the rate of HIV type 1 (HIV-1) seroconversion. RESULTS: A total of 77 participants in the dapivirine group underwent HIV-1 seroconversion during 1888 person-years of follow-up (4.1 seroconversions per 100 person-years), as compared with 56 in the placebo group who underwent HIV-1 seroconversion during 917 person-years of follow-up (6.1 seroconversions per 100 person-years). The incidence of HIV-1 infection was 31% lower in the dapivirine group than in the placebo group (hazard ratio, 0.69; 95% confidence interval [CI], 0.49 to 0.99; P=0.04). There was no significant difference in efficacy of the dapivirine ring among women older than 21 years of age (hazard ratio for infection, 0.63; 95% CI, 0.41 to 0.97) and those 21 years of age or younger (hazard ratio, 0.85; 95% CI, 0.45 to 1.60; P=0.43 for treatment-by-age interaction). Among participants with HIV-1 infection, nonnucleoside reverse-transcriptase inhibitor resistance mutations were detected in 14 of 77 participants in the dapivirine group (18.2%) and in 9 of 56 (16.1%) in the placebo group. Serious adverse events occurred more often in the dapivirine group (in 38 participants [2.9%]) than in the placebo group (in 6 [0.9%]). However, no clear pattern was identified. CONCLUSIONS: Among women in sub-Saharan Africa, the dapivirine ring was not associated with any safety concerns and was associated with a rate of acquisition of HIV-1 infection that was lower than the rate with placebo. (Funded by the International Partnership for Microbicides; ClinicalTrials.gov number, NCT01539226 .)
Recommended from our members
Performance and Acceptability of the FC2 Female Condom When Used With and Without a Silicone Placebo Vaginal Ring-A Randomized, Crossover Trial.
BackgroundThe silicone Dapivirine Vaginal Ring 25 mg, has been developed to provide an additional HIV prevention option for women. If approved for use, women will always be counselled to use condoms when using the vaginal ring for maximum protection. This paper evaluates the compatibility of female condoms with the ring.MethodsThis was a 2-period crossover, randomized noninferiority trial. Couples in 2 sites in the United States of America were randomized to FC2 Female Condom (FC2) with and without a placebo silicone ring and asked to use 4 female condoms in each period. The primary noninferiority endpoint was the clinical failure rate during intercourse or withdrawal (self-reported clinical breakage, slippage, misdirection, and invagination). Frequencies and percentages were calculated for each failure mode and differences in performance of the 2 periods, using the female condom without the ring as reference. Noninferiority was defined using an 8% margin at the 5% significance level. Safety and tolerability were also assessed.ResultsEighty-one couples were enrolled and 79 completed the trial using a total of 596 female condoms (297 and 299 with/without a ring inserted, respectively). Total female condom clinical failure was 14.1% and 15.7% in the presence and absence of a ring, respectively, with a difference of -2.1% (95% confidence interval: -7.8% to 3.6%), thereby demonstrating noninferiority when used with the ring. There were no differences in safety and tolerability between the 2 periods.DiscussionConcurrent use of the placebo silicone vaginal ring had no significant effect on female condom functionality or safety outcomes
Recommended from our members
Performance of Male Condoms When Used With and Without a Silicone Placebo Vaginal Ring-A Randomized, Crossover Trial.
BackgroundThe dapivirine vaginal ring reduced the risk of HIV infection by approximately 30% in Phase III trials. To ensure higher levels of protection against HIV and sexually transmitted infections, women should be counseled to use condoms when using the vaginal ring. This article evaluates the compatibility of male condoms with a placebo vaginal ring.MethodsThis was a 2-period crossover, randomized, noninferiority trial. Couples in 2 sites in the United States were randomized to male condom use, with and without a placebo silicone vaginal ring, and asked to use 4 male condoms in each period. The primary noninferiority end points were total clinical failure and their component failure events (clinical breakage or slippage). Frequencies and percentages were calculated for each failure mode and differences in performance of the 2 periods using the male condom without the ring as reference. Noninferiority was defined using a 3% margin at the 5% significance level. Safety and acceptability were also assessed.ResultsSeventy couples were enrolled, and 68 completed the trial with a total of 275 male condoms used in each period. Total condom clinical failure rates were 2.2% and 4.0% in the presence and absence of the vaginal ring, respectively, with a difference of -1.9% (95% confidence interval: -5.3% to 1.5%), thereby demonstrating noninferiority when used with the ring. There was no difference in safety between the 2 periods.DiscussionConcurrent use of the placebo silicone vaginal ring had no significant effect on male condom functionality or safety outcomes
Recommended from our members
Performance and Acceptability of the FC2 Female Condom When Used With and Without a Silicone Placebo Vaginal Ring-A Randomized, Crossover Trial.
BackgroundThe silicone Dapivirine Vaginal Ring 25 mg, has been developed to provide an additional HIV prevention option for women. If approved for use, women will always be counselled to use condoms when using the vaginal ring for maximum protection. This paper evaluates the compatibility of female condoms with the ring.MethodsThis was a 2-period crossover, randomized noninferiority trial. Couples in 2 sites in the United States of America were randomized to FC2 Female Condom (FC2) with and without a placebo silicone ring and asked to use 4 female condoms in each period. The primary noninferiority endpoint was the clinical failure rate during intercourse or withdrawal (self-reported clinical breakage, slippage, misdirection, and invagination). Frequencies and percentages were calculated for each failure mode and differences in performance of the 2 periods, using the female condom without the ring as reference. Noninferiority was defined using an 8% margin at the 5% significance level. Safety and tolerability were also assessed.ResultsEighty-one couples were enrolled and 79 completed the trial using a total of 596 female condoms (297 and 299 with/without a ring inserted, respectively). Total female condom clinical failure was 14.1% and 15.7% in the presence and absence of a ring, respectively, with a difference of -2.1% (95% confidence interval: -7.8% to 3.6%), thereby demonstrating noninferiority when used with the ring. There were no differences in safety and tolerability between the 2 periods.DiscussionConcurrent use of the placebo silicone vaginal ring had no significant effect on female condom functionality or safety outcomes
Recommended from our members
Performance of Male Condoms When Used With and Without a Silicone Placebo Vaginal Ring-A Randomized, Crossover Trial.
BackgroundThe dapivirine vaginal ring reduced the risk of HIV infection by approximately 30% in Phase III trials. To ensure higher levels of protection against HIV and sexually transmitted infections, women should be counseled to use condoms when using the vaginal ring. This article evaluates the compatibility of male condoms with a placebo vaginal ring.MethodsThis was a 2-period crossover, randomized, noninferiority trial. Couples in 2 sites in the United States were randomized to male condom use, with and without a placebo silicone vaginal ring, and asked to use 4 male condoms in each period. The primary noninferiority end points were total clinical failure and their component failure events (clinical breakage or slippage). Frequencies and percentages were calculated for each failure mode and differences in performance of the 2 periods using the male condom without the ring as reference. Noninferiority was defined using a 3% margin at the 5% significance level. Safety and acceptability were also assessed.ResultsSeventy couples were enrolled, and 68 completed the trial with a total of 275 male condoms used in each period. Total condom clinical failure rates were 2.2% and 4.0% in the presence and absence of the vaginal ring, respectively, with a difference of -1.9% (95% confidence interval: -5.3% to 1.5%), thereby demonstrating noninferiority when used with the ring. There was no difference in safety between the 2 periods.DiscussionConcurrent use of the placebo silicone vaginal ring had no significant effect on male condom functionality or safety outcomes