81 research outputs found

    KD5170, a novel mercaptoketone-based histone deacetylase inhibitor that exhibits broad spectrum antitumor activity in vitro and in vivo

    Get PDF
    Abstract Histone deacetylase (HDAC) inhibitors have garnered significant attention as cancer drugs. These therapeutic agents have recently been clinically validated with the market approval of vorinostat (SAHA, Zolinza) for treatment of cutaneous T-cell lymphoma. Like vorinostat, most of the small-molecule HDAC inhibitors in clinical development are hydroxamic acids, whose inhibitory activity stems from their ability to coordinate the catalytic Zn 2+ in the active site of HDACs. We sought to identify novel, nonhydroxamate-based HDAC inhibitors with potentially distinct pharmaceutical properties via an ultra-high throughput small molecule biochemical screen against the HDAC activity in a HeLa cell nuclear extract. An A-mercaptoketone series was identified and chemically optimized. The lead compound, KD5170, exhibits HDAC inhibitory activity with an IC 50 of 0.045 Mmol/L in the screening biochemical assay and an EC 50 of 0.025 Mmol/L in HeLa cell -based assays that monitor histone H3 acetylation. KD5170 also exhibits broad spectrum classe

    Integration of optoelectronic components with LTCC (low temperature co-fired ceramic) microfluidic structure

    No full text
    Investigations on integration of optoelectronic components with LTCC (low temperature co-fired ceramics) microfluidic module are presented. Design, fabrication and characterization of the ceramic structure for optical absorbance is described as well. The geometry of the microfluidic channels has been designed according to results of the CFD (computational fluid dynamics) analysis. A fabricated LTCC-based microfluidic module consists of an U-shaped microchannel, two optical fibers and integrated light source (light emitting diode) and photodetector (light-to-voltage converter). Properties of the fabricated microfluidic system have been investigated experimentally. Several concentrations of potassium permanganate (KMnO4) in water were used for absorbance/transmittance measurements. The test has shown a linear detection range for various concentrations of heavy metal ions in distilled water. The fabricated microfluidic structure is found to be a very useful system in chemical analysis

    Selected aspects of developing microwave elements in LTCC modules

    No full text
    Artykuł prezentuje aspekty techniczne, które są istotne podczas wykonywania oraz projektowania zintegrowanych układów mikroprzepływowo-mikrofalowych. Zastosowanie techniki mikrofalowej w układach mikroprzepływowych otwiera nowe możliwości, które stanowią rozwiązanie części problemów występujących w układach mikroprzepływowych, takich jak wykorzystanie i dostarczanie energii cieplnej. Ponadto, mikrofale stanowią atrakcyjną alternatywę dla spotykanych obecnie metod charakteryzacji parametrów substancji umieszczonych w kanale mikroukładu. W związku z tym, przedstawiono typowe obszary zastosowań techniki mikrofalowej w modułach mikroprzepływowych. Opisano typowe podłoża, które są stosowane podczas wytwarzania wspomnianych układów, wraz z wyszczególnieniem ich cech charakterystycznych i porównaniem. Wskazano na korzyści płynące z zastosowania ceramiki LTCC (ang. Low temperature cofired ceramics, niskotemperaturowa ceramika współwypalana), jako materiału podłożowego pod układy mikroprzepływowo-mikrofalowe. Wyszczególniono możliwe do wykonania techniką LTCC typy prowadnic falowych wraz z odpowiednim położeniem mikrokanału w ceramicznym podłożu oraz dokonano krótkiego podsumowania.This paper descries aspects, which are significant during the process of designing and developing of integrated microfluidic-microwave modules. The application of microwaves in microfluidic modules ensures the new possibilities, such as a providing a heat to the selected parts of a microsystem. Furthermore, the microwaves are the alternative solution of characterization of parameters the substance in the microchannel. Therefore, the usual fields of microwave technique in microfluidic modules are presented. The most used substrates in mentioned devices are described and compared. The benefits of using the LTCC as the substrate of microfluidic-microwave devices are indicated. Furthermore, the most common used wave guides integrated with the geometry of microchannels in LTCC modules are presented

    The possibility to use the low-temperature co-fired ceramics (LTCC) in the mining industry

    No full text
    W artykule opisano technologię LTCC (niskotemperaturowa współwypalana ceramika, ang. Low Temperature Co-fired Ceramic) pod względem możliwości jej wykorzystania w przemyśle górniczym. Wskazano unikalne cechy technologii LTCC, które są istotne w przypadku wytwarzania układów elektronicznych przeznaczonych do pracy w trudnych warunkach środowiskowych, takich jak podwyższona temperatura, ciśnienie oraz wilgotność. Opisano przykładowe rozwiązania bazujące na technice LTCC obecne w literaturze przedmiotu, wskazujące na możliwość ich zastosowania w przemyśle wydobywczym.This article presents LTCC (Low Temperature Co-Fired Ceramic) in terms of using ceramic substrates as base of electronic devices in the mining industry. Technological attributes of substrate material are significant aspects of the perspective of choosing type of electronic systems in harsh environment (such as elevated temperatures, pressures and humidity). Technological process of manufacturing LTCC multilayer was described. Examples of LTCC-based solutions are presented, with particular emphasis on wireless sensor system tested in coalmine

    Neurotransmitters detection using a fluorescence-based sensor with graphene quantum dots

    No full text
    In the paper, the development and performance of an optical sensor for detection of neurotransmitters (dopamine) is presented. The concentration of dopamine is measured basing on fluorescence quenching of graphene quantum dots. In the sensor, the dopamine molecules coat the graphene quantum dots surface – in result, the quenching of fluorescence occurs due to the Förster resonance energy transfer. The changes in fluorescence correspond to specific concentrations of the neurotransmitter in tested samples, so it is possible to accurately determine the concentration of dopamine in the sample

    Badanie właściwości termistorów wykonanych na podłożach LTCC

    No full text
    The work is conducted on NTC (Negative Temperature Coefficient) thermistors. An influence of different type of the substrate (DP 951 and lead free ESL 41020) on basic electrical properties: sheet resistance at a room temperature, R = f(T) dependence, B constant and a long-term stability is analyzed. The resistance values are measured twenty times in the range from 25°C to 125°C at 5°C intervals, while temperature is recorded using Pt-100 resistor. Long-term stability is investigated by annealing at 150°C for 200 h.W pracy przedstawiono wyniki badań związanych z elementami termistorowymi NTC (Negative Temperature Coefficient). Zbadano wpływ rodzaju podłoża (DP 951 i bezołowiowego ESL 41020) oraz konfiguracji elementów (zagrzebane, powierzchniowe) na podstawowe parametry elektryczne: rezystancję na kwadrat, zależność rezystancji od temperatury, stałą termistorową B, stabilność długo terminową. Wartości rezystancji były mierzone 20 razy w zakresie od 25°C do 125°C ze skokiem 5°C temperatura była mierzona za pomocą rezystora PT-100. Stabilność długoterminowa była badana przez wygrzewanie w 150°C przez 200 h

    Influence of tapes\u27 properties on the laser cutting process

    No full text
    Ceramic tapes are used to build 3-dimensional components and microsystems in layer manufacturing. The tapes are individually printed and structured before being stacked and laminated. The structuring process of the tapes affects the maximal resolution of fluidic channels, suspended bridges and beams, which in turn determines the scale of miniaturization of the produced components. The aim of this paper is to investigate if the tape composition can be optimized to improve the cutting resolution of laser cutting, which is a very flexible tool for micromachining. Using the Siemens star pattern, the laser cutting resolution was measured for alumina green tapes of different binder compositions with different laser settings. For all tapes the resolution was better the higher the laser beam velocity. At higher velocity though, a higher number of cutting cycles is necessary to cut the tape. The laser cutting resolution depends on the binder composition, but the laser parameters must also be optimized to achieve high cutting resolution