1,133 research outputs found

    OPTIMIZATION OF RFID SYSTEM COVERAGE IN A MANUFACTURING ENVIRONMENT

    Get PDF
    This paper compiles existing ideas, theories, and experiments across multiple disciplines to provide guidance for a company looking to implement an optimal RFID system in their production facility. The desire is to maximize the information received by the system while minimizing the cost. Four potential layouts of RFID antennas, two with overlapping antenna coverage and two with non-overlapping layouts, are first analyzed to understand the special coverage and the number of antennas required. The value of information is then quantified to determine whether higher coverage layouts are worth the additional costs associated with the higher number of antennas required. It was found that the non-overlapping network of antennas in a hexagonal lattice formation, which covers 90.7% of the production floor area, provides the highest amount of benefit when considering the system’s implementation costs. However, some companies prefer or even require a system that provides perfect information throughout the production process, so implementing an overlapping network may be considered optimal for some companies, even with the higher up front costs

    Walking in Hypoxia: An Efficient Treatment to Lessen Mechanical Constraints and Improve Health in Obese Individuals?

    Get PDF
    Obesity is defined as a body mass index >30 kg/m2 and is a major health burden in many parts of the world (Finucane et al., 2011)..

    Is altitude training an efficient treatment for obesity?

    Get PDF
    Worldwide, about half the adult population is considered overweight as defined by a body mass index (BMI - calculated by body weight divided by height squared) ratio in excess of 25 kg.m-2. Of these individuals, half are clinically obese (with a BMI in excess of 30) and these numbers are still increasing, notably in developing countries such as those of the Middle East region. Obesity is a disorder characterised by increased mass of adipose tissue (excessive fat accumulation) that is the result of a systemic imbalance between food intake and energy expenditure. Although factors such as family history, sedentary lifestyle, urbanisation, income and family diet patterns determine obesity prevalence, the main underlying causes are poor knowledge about food choice and lack of physical activity3. Current obesity treatments include dietary restriction, pharmacological interventions and ultimately, bariatric surgery. The beneficial effects of physical activity on weight loss through increased energy expenditure and appetite modulation are also firmly established. Another viable option to induce a negative energy balance, is to incorporate hypoxia per se or combine it with exercise in an individual's daily schedule. This article will present recent evidence suggesting that combining hypoxic exposure and exercise training might provide a cost-effective strategy for reducing body weight and improving cardio-metabolic health in obese individuals. The efficacy of this approach is further reinforced by epidemiological studies using large-scale databases, which evidence a negative relationship between altitude of habitation and obesity. In the United States, for instance, obesity prevalence is inversely associated with altitude of residence and urbanisation, after adjusting for temperature, diet, physical activity, smoking and demographic factors

    Modes of extensional faulting controlled by surface processes

    Get PDF
    We investigate the feedbacks between surface processes and tectonics in an extensional setting by coupling a 2-D geodynamical model with a landscape evolution law. Focusing on the evolution of a single normal fault, we show that surface processes significantly enhance the amount of horizontal extension a fault can accommodate before being abandoned in favor of a new fault. In simulations with very slow erosion rates, a 15 km thick brittle layer extends via a succession of crosscutting short-lived faults (heave 10 km). Using simple scaling arguments, we quantify the effect of surface mass removal on the force balance acting on a growing normal fault. This leads us to propose that the major range-bounding normal faults observed in many continental rifts owe their large offsets to erosional and depositional processes

    The Determinants of the Preferred Walking Speed in Individuals with Obesity.

    Get PDF
    The preferred walking speed (PWS), also known as the "spontaneous" or "self-selected" walking speed, is the speed normally used during daily living activities and may represent an appropriate exercise intensity for weight reduction programs aiming to enhance a more negative energy balance. The aim of this study was to examine, simultaneously, the energetics, mechanics, and perceived exertion determinants of PWS in individuals with obesity. Twenty-three adults with obesity (age 32.7 ± 6.8 years, body mass index 33.6 ± 2.6 kg/m2) were recruited. The participants performed 10 min of treadmill familiarization, and PWS was determined. Each subject performed six 5-min walking trials (PWS 0.56, 0.83, 1.11, 1.39, and 1.67 m/s). Gas exchanges were collected and analyzed to obtain the gross energy cost of walking (GCw), rated perceived exertion (RPE) was measured using a 6-20 Borg scale, and the external mechanical work (Wext) and the fraction of mechanical energy recovered by the pendular mechanism (Recovery) were computed using an instrumented treadmill. Second-order least-squares regression was used to calculate the optimal walking speed (OWS) of each variable. No significant difference was found between PWS (1.28 ± 0.13 m/s) and OWS for GCw (1.28 ± 0.10 m/s), RPE cost of walking (1.38 ± 0.14 m/s), and Recovery (1.48 ± 0.27 m/s; p > 0.06 for all), but the PWS was significantly faster than the OWS for Wext (0.98 ± 0.56 m/s; p < 0.02). Multiple regression (r = 0.72; p = 0.003) showed that ∼52% of the variance in PWS was explained by Recovery, Wext, and height. The main finding of this study was that obese adults may select their PWS in function of several competing demands, since this speed simultaneously minimizes pendular energy transduction, energy cost, and perceived exertion during walking. Moreover, recovery of mechanical work, external work, and height seem to be the major determinants of PWS in these individuals

    Spin and Charge Luttinger-Liquid Parameters of the One-Dimensional Electron Gas

    Full text link
    Low-energy properties of the homogeneous electron gas in one dimension are completely described by the group velocities of its charge (plasmon) and spin collective excitations. Because of the long range of the electron-electron interaction, the plasmon velocity is dominated by an electrostatic contribution and can be estimated accurately. In this Letter we report on Quantum Monte Carlo simulations which demonstrate that the spin velocity is substantially decreased by interactions in semiconductor quantum wire realizations of the one-dimensional electron liquid.Comment: 13 pages, figures include

    Jastrow correlation factor for atoms, molecules, and solids

    Get PDF
    A form of Jastrow factor is introduced for use in quantum Monte Carlo simulations of finite and periodic systems. Test data are presented for atoms, molecules, and solids, including both all-electron and pseudopotential atoms. We demonstrate that our Jastrow factor is able to retrieve a large fraction of the correlation energy

    Critical speed estimated by statistically appropriate fitting procedures.

    Get PDF
    Intensity domains are recommended when prescribing exercise. The distinction between heavy and severe domains is made by the critical speed (CS), therefore requiring a mathematically accurate estimation of CS. The different model variants (distance versus time, running speed versus time, time versus running speed, and distance versus running speed) are mathematically equivalent. Nevertheless, error minimization along the correct axis is important to estimate CS and the distance that can be run above CS (d'). We hypothesized that comparing statistically appropriate fitting procedures, which minimize the error along the axis corresponding to the properly identified dependent variable, should provide similar estimations of CS and d' but that different estimations should be obtained when comparing statistically appropriate and inappropriate fitting procedure. Sixteen male runners performed a maximal incremental aerobic test and four exhaustive runs at 90, 100, 110, and 120% of their peak speed on a treadmill. Several fitting procedures (a combination of a two-parameter model variant and regression analysis: weighted least square) were used to estimate CS and d'. Systematic biases (P < 0.001) were observed between each pair of fitting procedures for CS and d', even when comparing two statistically appropriate fitting procedures, though negligible, thus corroborating the hypothesis. The differences suggest that a statistically appropriate fitting procedure should be chosen beforehand by the researcher. This is also important for coaches that need to prescribe training sessions to their athletes based on exercise intensity, and their choice should be maintained over the running seasons

    Both a single sacral marker and the whole-body center of mass accurately estimate peak vertical ground reaction force in running.

    Get PDF
    While running, the human body absorbs repetitive shocks with every step. These shocks can be quantified by the peak vertical ground reaction force (F <sub>v,max</sub> ). To measure so, using a force plate is the gold standard method (GSM), but not always at hand. In this case, a motion capture system might be an alternative if it accurately estimates F <sub>v,max</sub> . The purpose of this study was to estimate F <sub>v,max</sub> based on motion capture data and validate the obtained estimates with force plate-based measures. One hundred and fifteen runners participated at this study and ran at 9, 11, and 13 km/h. Force data (1000 Hz) and whole-body kinematics (200 Hz) were acquired with an instrumented treadmill and an optoelectronic system, respectively. The vertical ground reaction force was reconstructed from either the whole-body center of mass (COM-M) or sacral marker (SACR-M) accelerations, calculated as the second derivative of their respective positions, and further low-pass filtered using several cutoff frequencies (2-20 Hz) and a fourth-order Butterworth filter. The most accurate estimations of F <sub>v,max</sub> were obtained using 5 and 4 Hz cutoff frequencies for the filtering of COM and sacral marker accelerations, respectively. GSM, COM-M, and SACR-M were not significantly different at 11 km/h but were at 9 and 13 km/h. The comparison between GSM and COM-M or SACR-M for each speed depicted root mean square error (RMSE) smaller or equal to 0.17BW (≤6.5 %) and no systematic bias at 11 km/h but small systematic biases at 9 and 13 km/h (≤0.09 BW). COM-M gave systematic biases three times smaller than SACR-M and two times smaller RMSE. The findings of this study support the use of either COM-M or SACR-M using data filtered at 5 and 4 Hz, respectively, to estimate F <sub>v,max</sub> during level treadmill runs at endurance speeds
    corecore