10 research outputs found

    Biomechanical techniques to evaluate tibial rotation: a systematic review

    Get PDF
    Purpose: This article systematically reviewed the biomechanical techniques to quantify tibial rotation, for an overview of how to choose a suitable technique for specific clinical application. Methods: A systematic search was conducted and finally 110 articles were included in this study. The articles were categorized by the conditions of how the knee was examined: external load application, physical examination and dynamic task. Results: The results showed that two-thirds of the included studies measured tibial rotation under external load application, of which over 80% of the experiments employed a cadaveric model. The common techniques used included direct displacement measurement, motion sensor, optical tracking system and universal force moment sensor. Intra-operative navigation system was used to document tibial rotation when the knee was examined by clinical tests. For dynamic assessment of knee rotational stability, motion analysis with skin reflective markers was frequently used although this technique is less accurate due to the skin movement when compared with radiographic measurement. Conclusion: This study reports various biomechanical measurement techniques to quantify tibial rotation in the literatures. To choose a suitable measurement technique for a specific clinical application, it is suggested to quantify the effectiveness of a new designed surgical technique by using a cadaveric model before applying to living human subjects for intra-operative evaluation or long-time functional stability assessment. Attention should also be paid on the study's purpose, whether to employ a cadaveric model and the way of stress applied to the knee. Level of evidence: IV

    Knee stability assessment on anterior cruciate ligament injury: clinical and biomechanical approaches

    Get PDF
    Anterior cruciate ligament (ACL) injury is common in knee joint accounting for 40% of sports injury. ACL injury leads to knee instability, therefore, understanding knee stability assessments would be useful for diagnosis of ACL injury, comparison between operation treatments and establishing return-to-sport standard. This article firstly introduces a management model for ACL injury and the contribution of knee stability assessment to the corresponding stages of the model. Secondly, standard clinical examination, intra-operative stability measurement and motion analysis for functional assessment are reviewed. Orthopaedic surgeons and scientists with related background are encouraged to understand knee biomechanics and stability assessment for ACL injury patients

    A non-invasive biomechanical device to quantify knee rotational laxity: Verification of the device in human cadaveric specimens

    Get PDF
    Background: Biomechanical measurement tools have been developed and widely used to precisely quantify knee anterior-posterior laxity after anterior cruciate ligament (ACL) injury. However, validated objective device to document knee rotational laxity, though being developed by different researchers, are not yet widely used in the daily clinical practice. A new biomechanical device was developed to quantify knee internal and external rotations. Methods: The reliability of the new biomechanical device which measures knee rotations were tested. Different torques (1-10Nm) were applied by the device to internally and externally rotate human cadaveric knees, which were held in a flexion angle of 30 . The rotations were measured by the device in degrees. There were two independent testers, and each tester carried out three trials. Intra-rater and inter-rater reliability were quantified in terms of intraclass correlation (ICC) coefficient among trials and between testers. The device was verified by the comparison with a computer assisted navigation system. ICC was measured. Mean, standard deviation and 95% confident interval of the difference as well as the root mean square difference were calculated. The correlations were deemed to be reliable if the ICC was above 0.75. Results: The intra-rater and inter-rater reliability achieved high correlation for both internal and external rotation, ranged from 0.959 to 0.992. ICC between the proposed meter and the navigation system for both internal and external rotation was 0.78. The mean differences were 2.3 and 2.5 for internal and external rotation respectively. Conclusions: A new knee rotational laxity meter was proposed in this study. Its reliability was verified by showing high correlation among trials. It also showed good correlation to a gold standard of measurement. It might be used to document knee rotational laxity for various purposes, especially after ACL injury, after further validation of the device in human subject

    Effect of medial arch-heel support in inserts on reducing ankle eversion: a biomechanics study

    Get PDF
    Background. Excessive pronation (or eversion) at ankle joint in heel-toe running correlated with lower extremity overuse injuries. Orthotics and inserts are often prescribed to limit the pronation range to tackle the problem. Previous studies revealed that the effect is product-specific. This study investigated the effect of medial arch-heel support in inserts on reducing ankle eversion in standing, walking and running. Methods. Thirteen pronators and 13 normal subjects participated in standing, walking and running trials in each of the following conditions: (1) barefoot, and shod condition with insert with (2) no, (3) low, (4) medium, and (5) high medial arch-heel support. Motions were captured and processed by an eight-camera motion capture system. Maximum ankle eversion was calculated by incorporating the raw coordinates of 15 anatomical positions to a self-compiled Matlab program with kinematics equations. Analysis of variance with repeated measures with post-hoc Tukey pairwise comparisons was performed on the data among the five walking conditions and the five running conditions separately. Results. Results showed that the inserts with medial arch-heel support were effective in dynamics trials but not static trials. In walking, they successfully reduced the maximum eversion by 2.1 degrees in normal subjects and by 2.5-3.0 degrees in pronators. In running, the insert with low medial arch support significantly reduced maximum eversion angle by 3.6 and 3.1 degrees in normal subjects and pronators respectively. Conclusion. Medial arch-heel support in inserts is effective in reducing ankle eversion in walking and running, but not in standing. In walking, there is a trend to bring the over-pronated feet of the pronators back to the normal eversion range. In running, it shows an effect to restore normal eversion range in 84% of the pronators

    Comparison of two surgical techniques for reconstructing posterolateral corner of the knee: a cadaveric study evaluated by navigation system

    Get PDF
    Purpose: This study aimed to evaluate the immediate effect on knee kinematics by 2 different techniques of posterolateral corner (PLC) reconstruction. Methods: Five intact formalin-preserved cadaveric knees were used in this study. A navigation system was used to measure knee kinematics (posterior translation, varus angulation, and external rotation) after application of a constant force and torque to the tibia. Four different conditions of the knee were evaluated during the biomechanical test: intact knee and PLC-sectioned knee and PLC-reconstructed knee by the doublefemoral tunnel technique and singlefemoral tunnel technique. Results: Sectioning of the PLC structures resulted in significant increases in external rotation at 30° of flexion from 11.2° (SD, 2.6) to 24.6° (SD, 6.2), posterior translation at 30° of flexion from 3.4 mm (SD, 1.5) to 7.4 mm (SD, 3.8), and varus angulation at 0° of flexion from 2.3° (SD, 2.1) to 7.9° (SD, 5.1). Both reconstruction techniques significantly restored the varus stability. The external rotation and posterior translation at 30° of flexion after reconstruction with the doublefemoral tunnel technique were 10.2° (SD, 1.3) and 3.4° (SD, 2.7), respectively, which were significantly better than those of the singlefemoral tunnel technique. Conclusions: Both techniques of reconstruction showed improved stability compared with PLC-sectioned knees. The doublefemoral tunnel technique in PLC reconstruction showed better rotational stability and resistance to posterior translation than the singlefemoral tunnel technique without compromising varus stability. Clinical Relevance: PLC reconstruction by a doublefemoral tunnel technique achieves better rotational control and resistance to posterior translation

    Effect of anticipation on knee kinematics during a stop-jump task

    Get PDF
    Knee stability during a functional assessment of the stop-jump task is a key factor to determine if an athlete is adequately rehabilitated after knee ligamentous injury. This study aimed to investigate knee stability due to the effect of anticipation on landing maneuvers during planned and unplanned stop-jump tasks. Knee kinematics of ten healthy male participants were collected using an optical motion analysis system during stop-jump tasks. Stop jumps were performed in four different landing positions either in planned movement or in an unplanned movement on a signal triggered as participants passed through a photocell gate. Kinematic data at the time of foot strike at landing in the stop-jump considered for investigating the anticipation effect during the stop-jump tasks. Two-way multivariate analysis of variance (MANOVA) with repeated measures and stratified paired t-tests were conducted to compare the knee kinematics data between planned and unplanned tasks. Statistical significance was set at the p< 0.05 level. External rotational angle showed a significant decrease in unplanned stop-jump tasks during forward (p< 0.05) and right (p< 0.05) jumps when compared to that of planned tasks. Flexion angle and abduction angle during forward, vertical and right jumps were significantly decreased in the unplanned tasks. Anticipation significantly influenced the landing maneuvers of stop-jump task. The results indicated that both planned and unplanned stop-jump tasks should be considered when monitoring the rehabilitation progress after a ligamentous injury

    Results of walking trial with walking shoe and walking inserts (W series)

    No full text
    <p><b>Copyright information:</b></p><p>Taken from "Effect of medial arch-heel support in inserts on reducing ankle eversion: a biomechanics study"</p><p>http://www.josr-online.com/content/3/1/7</p><p>Journal of Orthopaedic Surgery and Research 2008;3():7-7.</p><p>Published online 20 Feb 2008</p><p>PMCID:PMC2266906.</p><p></p

    Results of static trial with running shoe and running inserts (R series)

    No full text
    <p><b>Copyright information:</b></p><p>Taken from "Effect of medial arch-heel support in inserts on reducing ankle eversion: a biomechanics study"</p><p>http://www.josr-online.com/content/3/1/7</p><p>Journal of Orthopaedic Surgery and Research 2008;3():7-7.</p><p>Published online 20 Feb 2008</p><p>PMCID:PMC2266906.</p><p></p

    Results of running trial with running shoe and running inserts (R series)

    No full text
    <p><b>Copyright information:</b></p><p>Taken from "Effect of medial arch-heel support in inserts on reducing ankle eversion: a biomechanics study"</p><p>http://www.josr-online.com/content/3/1/7</p><p>Journal of Orthopaedic Surgery and Research 2008;3():7-7.</p><p>Published online 20 Feb 2008</p><p>PMCID:PMC2266906.</p><p></p

    Results of static trial with walking shoe and walking inserts (W series)

    No full text
    <p><b>Copyright information:</b></p><p>Taken from "Effect of medial arch-heel support in inserts on reducing ankle eversion: a biomechanics study"</p><p>http://www.josr-online.com/content/3/1/7</p><p>Journal of Orthopaedic Surgery and Research 2008;3():7-7.</p><p>Published online 20 Feb 2008</p><p>PMCID:PMC2266906.</p><p></p
    corecore