60 research outputs found

    Shifted Excitation Raman Difference Spectroscopy Applied to Extraterrestrial Particles Returned from the Asteroid Itokawa

    Get PDF
    Two extraterrestrial particles from the asteroid Itokawa are investigated applying Shifted Excitation Raman Difference Spectroscopy (SERDS). These particles were returned by the Hayabusa mission of the Japanese Space Agency JAXA. For SERDS a diode laser based microsystem light source at 488 nm is used for excitation. It has been found that fluorescence signals masking the Raman spectral features of interest can be substantially separated by applying SERDS. Therefore, SERDS improves the information obtained from the Raman spectra and enables a reliable analysis for investigations on extraterrestrial samples

    Design of a mode converter for efficient light-atom coupling in free space

    Full text link
    In this article, we describe how to develop a mode converter that transforms a plane electromagnetic wave into an inward moving dipole wave. The latter one is intended to bring a single atom or ion from its ground state to its excited state by absorption of a single photon wave packet with near-100% efficiency.Comment: RevTex4, 3 figures, revised version, accepted for publication at Appl. Phys.

    Effects of Anacetrapib in Patients with Atherosclerotic Vascular Disease

    Get PDF
    BACKGROUND: Patients with atherosclerotic vascular disease remain at high risk for cardiovascular events despite effective statin-based treatment of low-density lipoprotein (LDL) cholesterol levels. The inhibition of cholesteryl ester transfer protein (CETP) by anacetrapib reduces LDL cholesterol levels and increases high-density lipoprotein (HDL) cholesterol levels. However, trials of other CETP inhibitors have shown neutral or adverse effects on cardiovascular outcomes. METHODS: We conducted a randomized, double-blind, placebo-controlled trial involving 30,449 adults with atherosclerotic vascular disease who were receiving intensive atorvastatin therapy and who had a mean LDL cholesterol level of 61 mg per deciliter (1.58 mmol per liter), a mean non-HDL cholesterol level of 92 mg per deciliter (2.38 mmol per liter), and a mean HDL cholesterol level of 40 mg per deciliter (1.03 mmol per liter). The patients were assigned to receive either 100 mg of anacetrapib once daily (15,225 patients) or matching placebo (15,224 patients). The primary outcome was the first major coronary event, a composite of coronary death, myocardial infarction, or coronary revascularization. RESULTS: During the median follow-up period of 4.1 years, the primary outcome occurred in significantly fewer patients in the anacetrapib group than in the placebo group (1640 of 15,225 patients [10.8%] vs. 1803 of 15,224 patients [11.8%]; rate ratio, 0.91; 95% confidence interval, 0.85 to 0.97; P=0.004). The relative difference in risk was similar across multiple prespecified subgroups. At the trial midpoint, the mean level of HDL cholesterol was higher by 43 mg per deciliter (1.12 mmol per liter) in the anacetrapib group than in the placebo group (a relative difference of 104%), and the mean level of non-HDL cholesterol was lower by 17 mg per deciliter (0.44 mmol per liter), a relative difference of -18%. There were no significant between-group differences in the risk of death, cancer, or other serious adverse events. CONCLUSIONS: Among patients with atherosclerotic vascular disease who were receiving intensive statin therapy, the use of anacetrapib resulted in a lower incidence of major coronary events than the use of placebo. (Funded by Merck and others; Current Controlled Trials number, ISRCTN48678192 ; ClinicalTrials.gov number, NCT01252953 ; and EudraCT number, 2010-023467-18 .)

    Low-dose vs high-dose paclitaxel-coated balloons for femoropopliteal lesions: 2-Year results from the COMPARE Trial.

    No full text
    Background: So far only 1-year data have been reported for direct comparisons of paclitaxel-coated balloons (PCBs) using different coating technologies. Objectives: The aim of this study was to report the 24-month results on the efficacy and safety of low-dose vs high-dose PCBs with nominal paclitaxel densities of 2.0 and 3.5 μg/mm2 and different coating technologies for femoropopliteal interventions from the COMPARE (Compare I Pilot Study for the Treatment of Subjects With Symptomatic Femoropopliteal Artery Disease) trial. Procedural characteristics of clinically driven (CD) target lesion revascularization (TLR) were analyzed. Methods: Within a prospective, multicenter, clinical trial, 414 patients with symptomatic femoropopliteal lesions (Rutherford categories 2-4, maximum lesion length 30 cm) were randomly assigned in a 1:1 ratio to endovascular treatment with either a low-dose (Ranger) or a high-dose (IN.PACT) PCB after stratification for lesion length. Two-year follow-up included assessment of primary patency (defined as absence of CD TLR or binary restenosis with a peak systolic velocity ratio >2.4 by duplex ultrasound), safety, and functional and clinical outcomes. Results: At 2 years, the Kaplan-Meier estimates of primary patency were 70.6% and 71.4% for the low-dose and high-dose PCBs (log-rank P = 0.96), respectively. One major amputation occurred in the high-dose group, and rates of all-cause mortality (3.6% vs 2.2%; P = 0.55) and CD TLR (17.3% vs 13.0%; P = 0.31) were similar between the groups. Among a total of 57 CD TLRs, 44.6% were performed for reocclusion and 28.1% for in-stent restenosis. Functional and clinical benefits over baseline were sustained in both groups. Conclusions: The 2-year results of the COMPARE trial demonstrate a sustained treatment benefit of both low-dose and high-dose PCBs for femoropopliteal interventions including a wide range of lesion lengths. (Compare I Pilot Study for the Treatment of Subjects With Symptomatic Femoropopliteal Artery Disease; NCT02701543
    corecore