10 research outputs found

    Therapeutic angiography for giant bleeding gastro-duodenal artery pseudoaneurysm

    No full text
    We present the case of an 18-year-old female transferred to our center from an outside hospital due to persistent gastrointestinal bleeding. Two weeks prior to her transfer she underwent duodenal omentopexy for a perforated duodenal peptic ulcer. The patient underwent a computed tomography angiogram which identified the source of bleeding as a giant gastro-duodenal artery (GDA) pseudoaneurysm. The patient was taken to interventional radiology where successful microcoil embolization was performed. We present this rare case of a giant GDA pseudoaneurysm together with imaging and a review of the medical literature regarding prevalence, etiology and treatment options for visceral arterial aneurysms

    Assessing the development status of intraoperative fluorescence imaging for perfusion assessments, using the IDEAL framework

    No full text
    Objectives: Intraoperative fluorescence imaging is currently used in a variety of surgical fields for four main purposes: assessing tissue perfusion; identifying/localizing cancer; mapping lymphatic systems; and visualizing anatomy. To establish evidence-based guidance for research and practice, understanding the state of research on fluorescence imaging in different surgical fields is needed. We evaluated the evidence on fluorescence imaging for perfusion assessments using the Idea, Development, Exploration, Assessment, Long Term Study (IDEAL) framework, which was designed for describing the stages of innovation in surgery and other interventional procedures. Design: Narrative literature review with analysis of IDEAL stage of each field of study. Setting: All publications on intraoperative fluorescence imaging for perfusion assessments reported in PubMed through 2019 were identified for six surgical procedures: coronary artery bypass grafting (CABG), upper gastrointestinal (GI) surgery, colorectal surgery, solid organ transplantation, reconstructive surgery, and cerebral aneurysm surgery. Main outcome measures: The IDEAL stage of research evidence was determined for each specialty field using a previously described approach. Results: 196 articles (15 003 cases) were selected for analysis. Current status of research evidence was determined to be IDEAL Stage 2a for upper GI and transplantation surgery, IDEAL 2b for CABG, colorectal and cerebral aneurysm surgery, and IDEAL Stage 3 for reconstructive surgery. Using the technique resulted in a high (up to 50%) rate of revisions among surgical procedures, but its efficacy improving postoperative outcomes has not yet been demonstrated by randomized controlled trials in any discipline. Only one possible adverse reaction to intravenous indocyanine green was reported. Conclusions: Using fluorescence imaging intraoperatively to assess perfusion is feasible and appears useful for surgical decision making across a range of disciplines. Identifying the IDEAL stage of current research knowledge aids in planning further studies to establish the potential for patient benefit

    Use of fluorescence imaging and indocyanine green during colorectal surgery: Results of an intercontinental Delphi survey

    No full text
    BACKGROUND: Fluorescence imaging with indocyanine green is increasingly being used in colorectal surgery to assess anastomotic perfusion, and to detect sentinel lymph nodes. METHODS: In this 2-round, online, Delphi survey, 35 international experts were asked to vote on 69 statements pertaining to patient preparation and contraindications to fluorescence imaging during colorectal surgery, indications, technical aspects, potential advantages/disadvantages, and effectiveness versus limitations, and training and research. Methodological steps were adopted during survey design to minimize risk of bias. RESULTS: More than 70% consensus was reached on 60 of 69 statements, including moderate-strong consensus regarding fluorescence imaging's value assessing anastomotic perfusion and leak risk, but not on its value mapping sentinel nodes. Similarly, although consensus was reached regarding most technical aspects of its use assessing anastomoses, little consensus was achieved for lymph-node assessments. Evaluating anastomoses, experts agreed that the optimum total indocyanine green dose and timing are 5 to 10 mg and 30 to 60 seconds pre-evaluation, indocyanine green should be dosed milligram/kilogram, lines should be flushed with saline, and indocyanine green can be readministered if bright perfusion is not achieved, although how long surgeons should wait remains unknown. The only consensus achieved for lymph-node assessments was that 2 to 4 injection points are needed. Ninety-six percent and 100% consensus were reached that fluorescence imaging will increase in practice and research over the next decade, respectively. CONCLUSION: Although further research remains necessary, fluorescence imaging appears to have value assessing anastomotic perfusion, but its value for lymph-node mapping remains questionable
    corecore