1,398 research outputs found
Voices of Native Hawaiian Women: Perceptions, Responses and Needs Regarding Intimate Partner Violence
Using a community based participatory approach, individual interviews and focus groups were conducted with Native Hawaiian women to understand their cultural perceptions, responses, and needs regarding intimate partner violence (IPV). Semi-structured interview guides were used for both interviews. The overriding theme derived from content analysis is that IPV âstarts in the home,â it is learned in the family and in the community. Visible injuries requiring emergency care is commonly perceived as IPV. The response to IPV included a primary theme of âdefend the collective.â Intimate partner violence is understood to be a âfamily matter,â dealt within the family or by oneself. Native Hawaiian women who participated in this study sought to re-connect or establish relationships with self, others, spirit, natural elements, cultural practices, and community. Responding to IPV requires an understanding of cultural perceptions, responses, and needs of Native Hawaiians, with implications for families and communities. The needs expressed by Native Hawaiian participants reflect what they need to access âhealth.â Implications for health care providers require understanding how best to facilitate an individualâs access to âhealthâ vs. access to âhealth care.
Treatment of Advanced Emphysema with Emphysematous Lung Sealant (AeriSeal (R))
Background: This report summarizes initial tests of an emphysematous lung synthetic polymer sealant (ELS) designed to reduce lung volume in patients with advanced emphysema. Objectives: The primary study objective was to define a therapeutic strategy to optimize treatment safety and effectiveness. Methods: ELS therapy was administered bronchoscopically to 25 patients with heterogeneous emphysema in an open-label, noncontrolled study at 6 centers in Germany. Treatment was performed initially at 2-4 subsegments. After 12 weeks, patients were eligible for repeat therapy to a total of 6 sites. Safety and efficacy were assessed after 6 months. Responses were evaluated in terms of changes from baseline in lung physiology, functional capacity, and health-related quality of life. Follow-up is available for 21 of 25 patients. Results: Treatment was well tolerated. There were no treatment-related deaths (i.e. within 90 days of treatment), and an acceptable short-and long-term safety profile. Physiological and clinical benefits were observed at 24 weeks. Efficacy responses were better among Global Initiative for Chronic Obstructive Lung Disease (GOLD) stage III patients {[}n = 14; change in residual volume/total lung capacity (Delta RV/TLC) = -7.4 +/- 10.3%; Delta forced expiratory volume in 1 s (Delta FEV(1)) = +15.9 +/- 22.6%; change in forced vital capacity (Delta FVC) = +24.1 +/- 22.7%; change in carbon monoxide lung diffusion capacity (Delta DLCO) = +19.3 +/- 34.8%; change in 6-min walk test (Delta 6MWD) = +28.7 +/- 59.6 m; change in Medical Research Council Dyspnea (Delta MRCD) score = -1.0 +/- 1.04 units; change in St. George's Respiratory Questionnaire (Delta SGRQ) score = -9.9 +/- 15.3 units] than for GOLD stage IV patients (n = 7; Delta RV/TLC = -0.5 +/- 6.4%; Delta FEV 1 = +2.3 +/- 12.3%; Delta FVC = +2.6 +/- 21.1%; Delta DLCO = -2.8 +/- 17.2%; Delta 6MWD = +28.3 +/- 58.4 m; Delta MRCD = 0.3 +/- 0.81 units; Delta SGRQ = -6.7 +/- 7.0 units). Conclusions: ELS therapy shows promise for treating patients with advanced heterogeneous emphysema. Additional studies to assess responses in a larger cohort with a longer follow-up are warranted. Copyright (C) 2011 S. Karger AG, Base
Modeling the effects of concentration of solid nanoparticles in liquid feedstock injection on high-velocity suspension flame spray process
This paper presents the eïŹects of the concentration of solid nanoparticles in the liquid feedstock injection on the
high-velocity suspension ïŹame spray (HVSFS) process. Four diïŹerent concentrations of solid nanoparticles in suspension
droplets with various droplet diameters are used to study gas dynamics, vaporization rate, and secondary breakup. Two types of
injections, viz. surface and group, are used. The group-type injection increases the eïŹciency of droplet disintegration and the
evaporation process and reduces the gas cooling. The initiation of the fragmentation process is diïŹcult for small droplets carrying
a high concentration of nanoparticles. Also, smaller droplets undergo rapid vaporization, leaving clogs of nanoparticles in the
middle of the barrel. For larger droplets, severe fragmentation occurs inside the combustion chamber. For a higher concentration
of nanoparticles, droplets exit the gun without complete evaporation. The results suggest that, in coating applications involving a
higher concentration of nanoparticles, smaller droplet sizes are preferred
Prognosis and longitudinal changes of physical activity in idiopathic pulmonary fibrosis
Background: Physical activity (PA) is associated with disease severity in idiopathic pulmonary fibrosis (IPF), but longitudinal studies evaluating its prognostic value and changes over time are lacking. Methods: We measured PA (steps per day, SPD) in a cohort of 46 IPF-patients (mean age, 67 years; mean FVC, 76.1%pred.) by accelerometry at baseline, recorded survival status during 3 years follow-up and repeated measurements in survivors. We compared the prognostic value of PA to established mortality predictors including lung function (FVC, DLCO) and 6-min walking-distance (6MWD). Results: During follow-up (median 34 months) 20 patients (43%) died. SPD and FVC best identified non-survivors (AUROC-curve 0.79, p < 0.01). After adjustment for confounders (sex, age, therapy), a standardized increase (i.e. one SD) in SPD, FVC%pred. or DLCO%pred. was associated with a more than halved risk of death (HR < 0.50; p < 0.01). Compared to baseline, SPD, FVC, and 6MWD annually declined in survivors by 973 SPD, 130 ml and 9 m, resulting in relative declines of 48.3% (p < 0.001), 13.3% (p < 0.001) and 7.8% (p = 0.055), respectively. Conclusion: While PA predicts mortality of IPF patients similar to established functional measures, longitudinal decline of PA seems to be disproportionally large. Our data suggest that the clinical impact of disease progression could be underestimated by established functional measures
The Energy Spectrum of TeV Gamma-Rays from the Crab Nebula as measured by the HEGRA system of imaging air Cherenkov telescopes
The Crab Nebula has been observed by the HEGRA (High-Energy Gamma-Ray
Astronomy) stereoscopic system of imaging air Cherenkov telescopes (IACTs) for
a total of about 200 hrs during two observational campaigns: from September
1997 to March 1998 and from August 1998 to April 1999. The recent detailed
studies of system performance give an energy threshold and an energy resolution
for gamma-rays of 500 GeV and ~ 18%, respectively. The Crab energy spectrum was
measured with the HEGRA IACT system in a very broad energy range up to 20 TeV,
using observations at zenith angles up to 65 degrees. The Crab data can be
fitted in the energy range from 1 to 20 TeV by a simple power-law, which yields
dJg/dE = (2.79+/-0.02 +/- 0.5) 10^{-7} E^{-2.59 +/- 0.03 +/- 0.05}, ph m^{-2}
s^{-1} TeV^{-1} The Crab Nebula energy spectrum, as measured with the HEGRA
IACT system, agrees within 15% in the absolute scale and within 0.1 units in
the power law index with the latest measurements by the Whipple, CANGAROO and
CAT groups, consistent within the statistical and systematic errors quoted by
the experiments. The pure power-law spectrum of TeV gamma-rays from the Crab
Nebula constrains the physics parameters of the nebula environment as well as
the models of photon emission.Comment: to appear in ApJ, 29 pages, 6 figure
Rejection of the hypothesis that Markarian 501 TeV photons are pure Bose-Einstein condensates
The energy spectrum of the Blazar type galaxy Markarian 501 (Mrk 501) as
measured by the High-Energy-Gamma-Ray Astronomy (HEGRA) air Cerenkov telescopes
extends beyond 16 TeV and constitutes the most energetic photons observed from
an extragalactic object. A fraction of the emitted spectrum is possibly
absorbed in interactions with low energy photons of the diffuse extragalactic
infrared radiation, which in turn offers the unique possibility to measure the
diffuse infrared radiation density by TeV spectroscopy. The upper limit on the
density of the extragalactic infrared radiation derived from the TeV
observations imposes constraints on models of galaxy formation and stellar
evolution. One of the recently published ideas to overcome severe absorption of
TeV photons is based upon the assumption that sources like Mrk 501 could
produce Bose-Einstein condensates of coherent photons. The condensates would
have a higher survival probability during the transport in the diffuse
radiation field and could mimic TeV air shower events. The powerful
stereoscopic technique of the HEGRA air Cerenkov telescopes allows to test this
hypothesis by reconstructing the penetration depths of TeV air shower events:
Air showers initiated by Bose-Einstein condensates are expected to reach the
maximum of the shower development in the atmosphere earlier than single photon
events. By comparing the energy-dependent penetration depths of TeV photons
from Mrk 501 with those from the TeV standard-candle Crab Nebula and simulated
air shower events, we can reject the hypothesis that TeV photons from Mrk 501
are pure Bose-Einstein condensates.Comment: 9 pages, 2 figures, published by ApJ Letters, revised version
(simulation results added
The TeV Energy Spectrum of Mkn 501 Measured with the Stereoscopic Telescope System of HEGRA during 1998 and 1999
During 1997, the BL Lac object Mkn 501 went into an extraordinary state of
high X-ray and TeV gamma-ray activity, lasting more than 6 months. In this
paper we report on the TeV emission characteristics of the source in the
subsequent years of 1998 and 1999 as measured with the Stereoscopic Cherenkov
Telescope System of HEGRA (La Palma, Canary Islands). Our observations reveal a
1998-1999 mean emission level at 1 TeV of 1/3 of the flux of the Crab Nebula, a
factor of 10 lower than during the year of 1997. A dataset of 122 observations
hours with the HEGRA telescope system makes it possible to assess for the first
time the Mkn 501 TeV energy spectrum for a mean flux level substantially below
that of the Crab Nebula with reasonable statistical accuracy. Excluding the
data of a strong flare, we find evidence that the 1998--1999 low-flux spectrum
is substantially softer (by 0.44+-0.1(stat) in spectral index) than the 1997
time averaged spectrum. The 500 GeV to 10 TeV energy spectrum can well be
described by a power law model with exponential cutoff: dN/dE ~ E^(-alpha)
exp(-E/E0) with alpha=2.31+-0.22(stat), and E0=5.1 (-2.3+7.8)(stat) TeV. Within
statistical accuracy, also a pure power law model gives an acceptable fit to
the data: dN/dE ~ E^(-Gamma) with Gamma=2.76+-0.08(stat). After presenting the
1998-1999 TeV characteristics of the source we discuss the implications of the
results.Comment: Accepted for publication in The Astrophysical Journal, Part 1, on
August 4th, 200
Correlated intense X-ray and TeV activity of Mrk~501 in 1998 June
We present exactly simultaneous X-ray and TeV monitoring with {\it RXTE} and
HEGRA of the TeV blazar Mrk 501 during 15 days in 1998 June. After an initial
period of very low flux at both wavelengths, the source underwent a remarkable
flare in the TeV and X-ray energy bands, lasting for about six days and with a
larger amplitude at TeV energies than in the X-ray band. At the peak of the TeV
flare, rapid TeV flux variability on sub-hour timescales is found. Large
spectral variations are observed at X-rays, with the 3--20 keV photon index of
a pure power law continuum flattening from to on a
timescale of 2--3 days. This implies that during the maximum of the TeV
activity, the synchrotron peak shifted to energies keV, a behavior
similar to that observed during the longer-lasting, more intense flare in 1997
April. The TeV spectrum during the flare is described by a power law with
photon index and an exponential cutoff at 4 TeV; an
indication for spectral softening during the flare decay is observed in the TeV
hardness ratios. Our results generally support a scenario where the TeV photons
are emitted via inverse Compton scattering of ambient seed photons by the same
electron population responsible for the synchrotron X-rays. The simultaneous
spectral energy distributions (SEDs) can be fit with a one-zone
synchrotron-self Compton model assuming a substantial increase of the magnetic
field and the electron energy by a factor of 3 and 10, respectively.Comment: Accepted for publication in ApJ, Part
Simultaneous X-Ray and TeV Gamma-Ray Observations of the TeV Blazar Markarian 421 during February and May 2000
In this paper we present the results of simultaneous observations of the TeV
blazar Markarian 421 (Mrk 421) at X-ray and TeV Gamma-ray energies with the
Rossi X-Ray Timing Explorer (RXTE) and the stereoscopic Cherenkov Telescope
system of the HEGRA (High Energy Gamma Ray Astronomy) experiment, respectively.
The source was monitored from February 2nd to February 16th and from May 3rd to
May 8th, 2000. We discuss in detail the temporal and spectral properties of the
source. Remarkably, the TeV observations of February 7th/8th showed
statistically significant evidence for substantial TeV flux variability on 30
min time scale. We show the results of modeling the data with a time dependent
homogeneous Synchrotron Self-Compton (SSC) model. The X-ray and TeV gamma-ray
emission strengths and energy spectra together with the rapid flux variability
strongly suggest that the emission volume is approaching the observer with a
Doppler factor of 50 or higher. The different flux variability time scales
observed at X-rays and TeV Gamma-rays indicate that a more detailed analysis
will require inhomogeneous models with several emission zones.Comment: Accepted for Publication in ApJ, 21 Pages, 5 Figure
- âŠ