28 research outputs found

    Nanostructures in hydrogen peroxide sensing

    Get PDF
    In recent years, several devices have been developed for the direct measurement of hydrogen peroxide (H2O2 ), a key compound in biological processes and an important chemical reagent in industrial applications. Classical enzymatic biosensors for H2O2 have been recently outclassed by electrochemical sensors that take advantage of material properties in the nano range. Electrodes with metal nanoparticles (NPs) such as Pt, Au, Pd and Ag have been widely used, often in combination with organic and inorganic molecules to improve the sensing capabilities. In this review, we present an overview of nanomaterials, molecules, polymers, and transduction methods used in the optimization of electrochemical sensors for H2O2 sensing. The different devices are compared on the basis of the sensitivity values, the limit of detection (LOD) and the linear range of application reported in the literature. The review aims to provide an overview of the advantages associated with different nanostructures to assess which one best suits a target application.Fil: Trujillo, Ricardo Matias. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tucumán. Instituto Superior de Investigaciones Biológicas. Universidad Nacional de Tucumán. Instituto Superior de Investigaciones Biológicas; Argentina. Universidad Nacional de Tucumán. Facultad de Ciencias Exactas y Tecnología. Departamento de Bioingeniería. Laboratorio de Medios e Interfases; ArgentinaFil: Barraza, Daniela Estefanía. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tucumán. Instituto Superior de Investigaciones Biológicas. Universidad Nacional de Tucumán. Instituto Superior de Investigaciones Biológicas; Argentina. Universidad Nacional de Tucumán. Facultad de Ciencias Exactas y Tecnología. Departamento de Bioingeniería. Laboratorio de Medios e Interfases; ArgentinaFil: Zamora, Martín Lucas. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tucumán. Instituto Superior de Investigaciones Biológicas. Universidad Nacional de Tucumán. Instituto Superior de Investigaciones Biológicas; Argentina. Universidad Nacional de Tucumán. Facultad de Ciencias Exactas y Tecnología. Departamento de Bioingeniería. Laboratorio de Medios e Interfases; ArgentinaFil: Cattani Scholz, Anna. Universitat Technical Zu Munich; AlemaniaFil: Madrid, Rossana Elena. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tucumán. Instituto Superior de Investigaciones Biológicas. Universidad Nacional de Tucumán. Instituto Superior de Investigaciones Biológicas; Argentina. Universidad Nacional de Tucumán. Facultad de Ciencias Exactas y Tecnología. Departamento de Bioingeniería. Laboratorio de Medios e Interfases; Argentin

    Staple-based paper electrochemical platform for celiac disease diagnosis

    Get PDF
    A staple-based electrochemical platform is proposed for the first time as a simple and low-cost detection system for paper-based devices. The system, that incorporates small and disposable stainless-steel staples as electrodes (modified with carbon ink in the case of the working electrode) is combined with a paper strip and is carefully optimized with ferrocene carboxylic acid. As a proof-of-concept, it was employed for the enzymatic (HRP-based) immunoelectroanalytical detection of human tissue anti-transglutaminase (anti-tTG), biomarker for celiac disease diagnosis. The intensity of the current due to the electrochemical reduction of TMB (HRP substrate) was recorded chronoamperometrically at -0.2 V in different paper areas. A linear relationship between the current measured at 30 s and the logarithm of the concentration of anti-tTG in the range comprised between 3 and 100 U.mL-1 was obtained. Negative and positive controls produced expected values. Results demonstrated that the paper/staple-combined platform is very convenient for the detection of electroactive analytes and other compounds that can be determined indirectly in bioassays.Fil: Nanni, Paula Inés. Universidad de Oviedo; España. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tucumán. Instituto Superior de Investigaciones Biológicas. Universidad Nacional de Tucumán. Instituto Superior de Investigaciones Biológicas; Argentina. Universidad Nacional de Tucumán. Facultad de Ciencias Exactas y Tecnología. Departamento de Bioingeniería. Laboratorio de Medios e Interfases; ArgentinaFil: Gonzalez Lopez, Andrea. Universidad de Oviedo; EspañaFil: Nuñez Bajo, Estefanía. Universidad de Oviedo; EspañaFil: Madrid, Rossana Elena. Universidad Nacional de Tucumán. Facultad de Ciencias Exactas y Tecnología. Departamento de Bioingeniería. Laboratorio de Medios e Interfases; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tucumán. Instituto Superior de Investigaciones Biológicas. Universidad Nacional de Tucumán. Instituto Superior de Investigaciones Biológicas; ArgentinaFil: Fernandez Abedul, M. Teresa. Universidad de Oviedo; Españ

    Potentiometric textile-based pH sensor

    Get PDF
    Determining the pH of sweat provides valuable information for athletes and patient monitoring. This work presents a textile-based, highly sensitive pH sensor for pH determination. Three conductive fabrics (Argenmesh, Ristop silver and Sstainless steel mesh (SSM)) were modified with a pH sensitive electrodeposited iridium oxide film (EIROF). The three electrodeposited fabrics were characterized by impedance measurements. The stainless steel mesh showed the best sensitivity to pH changes and therefore was selected for further experiments. Two configurations of this fabric were evaluated, looking for improvement in pH sensitivity and temperature dependence. The best result was obtained with the configuration that maximizes the contact surface between the stainless steel fibers, showing an error of 0.15% in the pH measurement of a buffer solution. This configuration was also used to perform in vivo measurements, obtaining an error of 4% when compared to the measurements performed with a commercial pH test strip. The implementation of sensor into textiles brings some advantages such as comfort, biocompatibility and washability, among others; making the future incorporation of a sensor into a garment very possible.Fil: Zamora, Martín Lucas. Universidad Nacional de Tucumán. Facultad de Ciencias Exactas y Tecnología; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tucumán. Instituto Superior de Investigaciones Biológicas. Universidad Nacional de Tucumán. Instituto Superior de Investigaciones Biológicas; ArgentinaFil: Domínguez, Juan Martín. Universidad Nacional de Tucumán. Facultad de Ciencias Exactas y Tecnología; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tucumán. Instituto Superior de Investigaciones Biológicas. Universidad Nacional de Tucumán. Instituto Superior de Investigaciones Biológicas; ArgentinaFil: Trujillo, Ricardo Matias. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tucumán. Instituto Superior de Investigaciones Biológicas. Universidad Nacional de Tucumán. Instituto Superior de Investigaciones Biológicas; Argentina. Universidad Nacional de Tucumán. Facultad de Ciencias Exactas y Tecnología; ArgentinaFil: Goy, Carla Belen. Universidad Nacional de Tucumán. Facultad de Ciencias Exactas y Tecnología; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tucumán. Instituto Superior de Investigaciones Biológicas. Universidad Nacional de Tucumán. Instituto Superior de Investigaciones Biológicas; ArgentinaFil: Sanchez, Maria Alejandra. Universidad Nacional de Tucumán. Facultad de Ciencias Exactas y Tecnología; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tucumán. Instituto Superior de Investigaciones Biológicas. Universidad Nacional de Tucumán. Instituto Superior de Investigaciones Biológicas; ArgentinaFil: Madrid, Rossana Elena. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tucumán. Instituto Superior de Investigaciones Biológicas. Universidad Nacional de Tucumán. Instituto Superior de Investigaciones Biológicas; Argentina. Universidad Nacional de Tucumán. Facultad de Ciencias Exactas y Tecnología; Argentin

    Biochar material evaluation through shock electrodialysis phenomenon for sustainable separation devices

    Get PDF
    The availability of biomass associated with agroindustry residues provides enormous opportunities for new bioproducts applications for sustainable processes. Biochar is a cost-effective carbonaceous material which can serve as raw material to create new separation agents and microdevices for gas purification, water treatment, biomolecule separation, controlled drug delivery, electrochemical reactors, microseparators and many other advanced applications. In this work, we used biochar disks derived from biomass harvest residues as a porous media to study the shock electrodialysis phenomenon. A home-made cell for continuous electrolyte flow including two stainless steel electrodes was used to study this phenomenon. Comparative cyclic voltammetry measurements were performed using the cell in batch mode with 1x10-4 M KCl solution either including or not including the biochar porous media. The difference between both voltammetry profiles showed how the presence of the porous material modified the extension of the plateau zone related to the diffusion-limited current density, which allows to perform shock electrodialysis tests. A set of continuous flow runs considering both distilled water (2.0 ? 6.0 µS/cm) and 1x10-4 M KCl solution (~17 µS/cm) were performed under an applied electric potential previously selected from the voltammetry measurements. The continuous monitoring of the solution ion conductivity in the cell outlet throughout each run provided important insights. The decrease of the outlet ion conductivity when the electric potential was applied to the cell indicated the presence of ion concentration polarization through the biochar porous material. The polarization effect increased when flow velocities and electrolyte concentrations were lower. With a proper engineering design (geometry, thickness and morphology) and considering optimized operating conditions (flow rate, applied voltage and ion concentration), this cost-effective carbonaceous material may play an important role in the development of new separation technologies for water treatment.Fil: Montes, Paula. Universidad Nacional de Tucumán; ArgentinaFil: Antunez, Camila. Universidad Nacional de Tucumán; ArgentinaFil: Trujillo, Matías. Universidad Nacional de Tucumán; ArgentinaFil: Iglesias, Gabriela. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tucumán. Instituto Superior de Investigaciones Biológicas. Universidad Nacional de Tucumán. Instituto Superior de Investigaciones Biológicas; ArgentinaFil: Trejo González, José Adolfo. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tucumán. Instituto de Química del Noroeste. Universidad Nacional de Tucumán. Facultad de Bioquímica, Química y Farmacia. Instituto de Química del Noroeste; ArgentinaFil: Madrid, Rossana Elena. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tucumán. Instituto Superior de Investigaciones Biológicas. Universidad Nacional de Tucumán. Instituto Superior de Investigaciones Biológicas; ArgentinaFil: Avila, Adolfo María. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tucumán. Instituto de Química del Noroeste. Universidad Nacional de Tucumán. Facultad de Bioquímica, Química y Farmacia. Instituto de Química del Noroeste; ArgentinaXXIX Interamerican Congress of Chemical EngineeringTorontoCanadáCanadian Society for Chemical Engineerin

    Paper-based microfluidic device for electrochemical glucose determination

    Get PDF
    En los últimos años, la microfluídica basada en papel se ha vuelto una poderosa herramienta analítica de bajo costo para la detección de diversos analitos de interés. En este trabajo, desarrollamos una celda electroquímica en papel dibujada con lápiz (PPEC), con el propósito de fabricar un biosensor de glucosa. Se analizan tres configuraciones de electrodo diferentes, según su comportamiento electroquímico. La calibración del biosensor mostró una respuesta lineal y sensible para la determinación de glucosa. El diseño presentado es de bajo costo, fácil fabricación, ligero, portable y una alternativa ecológica para el biosensado de glucosa.In recent years, paper-based microfluidics has turned into a strong and low-cost analytical tool for detection of diverse analytes of interest. In this work, we develop a pencil-drawn paper-based electrochemical cell (PPEC), with the purpose of fabricating a glucose biosensor. Three different electrode configurations are analyzed as regards their electrochemical behaviour. Biosensor calibration showed a linear and sensitive response for glucose determination. The design presented here is a low-cost, easy to fabricate, lightweight, portable and a green alternative for glucose biosensing.Fil: Chaile, Roberto Ezequiel. Universidad Nacional de Tucumán. Facultad de Ciencias Exactas y Tecnología. Departamento de Bioingeniería. Laboratorio de Medios e Interfases; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tucumán. Instituto Superior de Investigaciones Biológicas. Universidad Nacional de Tucumán. Instituto Superior de Investigaciones Biológicas; ArgentinaFil: Nanni, Paula Inés. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tucumán. Instituto Superior de Investigaciones Biológicas. Universidad Nacional de Tucumán. Instituto Superior de Investigaciones Biológicas; Argentina. Universidad Nacional de Tucumán. Facultad de Ciencias Exactas y Tecnología. Departamento de Bioingeniería. Laboratorio de Medios e Interfases; ArgentinaFil: Goy, Carla Belen. Universidad Nacional de Tucumán. Facultad de Ciencias Exactas y Tecnología. Departamento de Bioingeniería. Laboratorio de Medios e Interfases; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tucumán. Instituto Superior de Investigaciones Biológicas. Universidad Nacional de Tucumán. Instituto Superior de Investigaciones Biológicas; ArgentinaFil: Barraza, Daniela Estefanía. Universidad Nacional de Tucumán. Facultad de Ciencias Exactas y Tecnología. Departamento de Bioingeniería. Laboratorio de Medios e Interfases; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tucumán. Instituto Superior de Investigaciones Biológicas. Universidad Nacional de Tucumán. Instituto Superior de Investigaciones Biológicas; ArgentinaFil: Ashur Ramallo, Fernando. Universidad Nacional de Tucumán. Facultad de Ciencias Exactas y Tecnología. Departamento de Bioingeniería. Laboratorio de Medios e Interfases; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tucumán. Instituto Superior de Investigaciones Biológicas. Universidad Nacional de Tucumán. Instituto Superior de Investigaciones Biológicas; ArgentinaFil: Madrid, Rossana Elena. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tucumán. Instituto Superior de Investigaciones Biológicas. Universidad Nacional de Tucumán. Instituto Superior de Investigaciones Biológicas; Argentina. Universidad Nacional de Tucumán. Facultad de Ciencias Exactas y Tecnología. Departamento de Bioingeniería. Laboratorio de Medios e Interfases; Argentin

    Microbial biomass estimation

    Get PDF
    The development of a fully automated on-line monitoring and control system is very important in bioprocesses. One of the most important parameters in these processes is biomass. This review discusses different methods for biomass quantification. A general definition of biomass and biovolume are presented. Interesting concepts about active but not culturable cells considerations are included as well as concepts that must be taken into account when selecting biomass quantification technology. Chemical methods have had few applications in biomass measurement to date; however, bioluminescence can selectively enumerate viable cells. Photometric methods including fluorescence and scattered light measurements are presented. Reference methods including dry and wet weight, viable counts and direct counts are discussed, as well as the physical methods of flow cytometry, impedancimetric and dielectric techniques.Fil: Madrid, Rossana Elena. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tucumán. Instituto Superior de Investigaciones Biológicas. Universidad Nacional de Tucumán. Instituto Superior de Investigaciones Biológicas; ArgentinaFil: Felice, Carmelo Jose. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tucumán. Instituto Superior de Investigaciones Biológicas. Universidad Nacional de Tucumán. Instituto Superior de Investigaciones Biológicas; Argentin

    Microfluidics and hydrogel: A powerful combination

    No full text
    Microfluidics is a very useful and promising technology that allowed engineering a huge variety of developments in several fields, such as biology, biomedical engineering, biotechnology, biochemistry, medicine and tissue engineering, among others. Moreover, when microfluidic is combined with hydrogel, the possibilities seem to be limitless. However, it is not found in the bibliography any report that shows the wide range of developments and application fields of this combination. In this review, the bibliography is explored by looking for these new systems that, combining microfluidics and hydrogels, substantially contribute to the state of the art. Seven large application fields are identified -from 649 papers reviewed-: 1) cell culture (out of the scope of this review), 2) biosensors, 3) gradient generator microdevices (GGMD), 4) active elements of hydrogel embedded into microfluidic devices, 5) separation devices, 6) models and 7) other uses. Most of these fields are presented and discussed in detail, the great benefits of the combination are highlighted and perspectives on future directions are exposed.Fil: Goy, Carla Belen. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tucumán. Instituto Superior de Investigaciones Biológicas. Universidad Nacional de Tucumán. Instituto Superior de Investigaciones Biológicas; Argentina. Universidad Nacional de Tucumán. Facultad de Ciencias Exactas y Tecnología. Departamento de Bioingeniería. Laboratorio de Medios e Interfases; Argentina. Universidad Nacional de Tucumán. Facultad de Ciencias Exactas y Tecnología. Departamento de Electricidad, Electrónica y Computación; ArgentinaFil: Chaile, Roberto Ezequiel. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tucumán. Instituto Superior de Investigaciones Biológicas. Universidad Nacional de Tucumán. Instituto Superior de Investigaciones Biológicas; Argentina. Universidad Nacional de Tucumán. Facultad de Ciencias Exactas y Tecnología. Departamento de Bioingeniería. Laboratorio de Medios e Interfases; ArgentinaFil: Madrid, Rossana Elena. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tucumán. Instituto Superior de Investigaciones Biológicas. Universidad Nacional de Tucumán. Instituto Superior de Investigaciones Biológicas; Argentina. Universidad Nacional de Tucumán. Facultad de Ciencias Exactas y Tecnología. Departamento de Bioingeniería. Laboratorio de Medios e Interfases; Argentin

    Enriching and controlling the CO2 concentration level in indoor farming through electroactive 13X-filled biocarbon tubular elements

    No full text
    Electrothermal biocarbon tubes filled up with zeolite 13X were studied as hybrid adsorbents for the CO2 enrichment of greenhouse’s environment through electric swing adsorption (ESA) cycles. These adsorbents captured CO2 from dilute CO2 gas streams with CO2 mole fractions as low as 1.0%. The direct heating of the adsorbent was achieved through the Joule effect by applying electric potential between the tube ends. Due to the rapid increase of the temperature, a CO2 enriched gas phase was released for the supply of CO2 in indoor grow rooms. A conceptual design of the ESA cycle was elaborated by using the equilibrium adsorption isobar curves estimated for these low CO2 levels. The presence of ambient air did not affect the carbonaceous material’s structure at high temperature. However, the CO2 enrichment was reduced by near 30%. The tube-shaped hybrid material demonstrated stability and repeatability for an effective CO2 supplementation in indoor agriculture.Fil: Aráoz, María Emilse. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tucumán. Instituto de Química del Noroeste. Universidad Nacional de Tucumán. Facultad de Bioquímica, Química y Farmacia. Instituto de Química del Noroeste; ArgentinaFil: Madrid, Rossana Elena. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet Noa Sur. Instituto Superior de Investigaciones Biológicas. Grupo de Investigación y Desarrollo del Noroeste Argentino | Universidad Nacional de Tucumán. Instituto Superior de Investigaciones Biológicas. Grupo de Investigación y Desarrollo del Noroeste Argentino; Argentina. Universidad Nacional de Tucumán. Facultad de Ciencias Exactas y Tecnología. Departamento de Bioingeniería. Laboratorio de Medios e Interfases; ArgentinaFil: Avila, Adolfo María. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tucumán. Instituto de Química del Noroeste. Universidad Nacional de Tucumán. Facultad de Bioquímica, Química y Farmacia. Instituto de Química del Noroeste; Argentin

    Zonal selectivity by sensitivity modulation in linear tetrapolar impedance sensors

    Get PDF
    This work investigates the behaviour of a tetrapolar impedance sensor due to sensitivity issues caused by inherent method measurement when inter-electrode spacing is changed. Finite Element Method (FEM) modelling of the sensitivity spectra was computed to analyse maximum sensitivity levels in desired zones of the sample and non-common known and unintuitive phenomenon as negative sensitivity lobes inside the sensitivity distribution field. Sensitivity maps as a function of electrode position were obtained and maximum sensitivity curves were extracted to identify the best configuration for major sensitivity contribution to characterize a specific sample section. A prototype of a linear tetrapolar sensor array of planar microelectrodes for sensing ionic samples was used for the computational modelling and a brief experimental validation was performed to show the vertical stratification process. The analysis shows that it is possible to have zonal selectivity in the impedance measurement and characterize a desired zone of the sample modulating the sensitivity, changing the electrode position by a scale pattern. This manuscript offers a novel approach for designing tetrapolar sensors based on analyzing maximum sensitivity curves obtained by FEM modelling.Fil: Moretti, Fabián N.. Universidad Tecnolócica Nacional.Facultad Regional Avellaneda.; ArgentinaFil: Cabrera, Jorge L.. Universidad Tecnolócica Nacional.Facultad Regional Avellaneda.; ArgentinaFil: Madrid, Rossana Elena. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tucumán. Instituto Superior de Investigaciones Biológicas. Universidad Nacional de Tucumán. Instituto Superior de Investigaciones Biológicas; Argentina. Universidad Nacional de Tucumán. Facultad de Ciencias Exactas y Tecnología. Departamento de Bioingeniería. Laboratorio de Medios e Interfases; Argentin

    Electroactive tube arrays of diatomaceous silica-filled biocarbon for CO2 separation through electric swing adsorption

    No full text
    Electroactive biocarbon tubes filled up with diatomaceous earth pellets were set up in a tube array for the CO2 separation through an Electric Swing Adsorption (ESA) cycle. The tube array was self-heated by applying voltage between its ends. The direct heating of the adsorbent material sped up the desorption step and thus quickly releasing an enriched CO2 gas phase. The dynamics of the tube array’s temperature and the CO2 molar fraction in the gas phase adsorbent showed consistency when consecutive ESA cycles were performed. In order to define the conceptual design of the ESA cycle, the CO2 competitive adsorption capacities were estimated for a set of CO2/N2 gas mixtures (≤10% CO2). The tubular adsorbent array essentially maintained its performance and structure when tested in the presence of air. The hybrid tube array demonstrated repeatability and stability for CO2 separation through consecutive ESA cycles. The tube array configuration is advantageous in terms of the process scale-up and modular chemical process intensification in the agroindustry.Fil: Aráoz, María Emilse. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tucumán. Instituto de Química del Noroeste. Universidad Nacional de Tucumán. Facultad de Bioquímica, Química y Farmacia. Instituto de Química del Noroeste; ArgentinaFil: Madrid, Rossana Elena. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tucumán. Instituto Superior de Investigaciones Biológicas. Universidad Nacional de Tucumán. Instituto Superior de Investigaciones Biológicas; ArgentinaFil: Avila, Adolfo María. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tucumán. Instituto de Química del Noroeste. Universidad Nacional de Tucumán. Facultad de Bioquímica, Química y Farmacia. Instituto de Química del Noroeste; Argentin
    corecore