48 research outputs found

    Reciprocity relation for the vector radiative transport equation and its application to diffuse optical tomography with polarized light

    Full text link
    We derive a reciprocity relation for vector radiative transport equation (vRTE) that describes propagation of polarized light in multiple-scattering media. We then show how this result, together with translational invariance of a plane-parallel sample, can be used to compute efficiently the sensitivity kernel of diffuse optical tomography (DOT) by Monte Carlo simulations. Numerical examples of polarization-selective sensitivity kernels thus computed are given.Comment: 5 pages, 3 figure

    Efficient inversion strategies for estimating optical properties with Monte Carlo radiative transport models

    Get PDF
    Significance: Indirect imaging problems in biomedical optics generally require repeated evaluation of forward models of radiative transport, for which Monte Carlo is accurate yet computationally costly. We develop an approach to reduce this bottleneck, which has significant implications for quantitative tomographic imaging in a variety of medical and industrial applications.Aim: Our aim is to enable computationally efficient image reconstruction in (hybrid) diffuse optical modalities using stochastic forward models.Approach: Using Monte Carlo, we compute a fully stochastic gradient of an objective function for a given imaging problem. Leveraging techniques from the machine learning community, we then adaptively control the accuracy of this gradient throughout the iterative inversion scheme to substantially reduce computational resources at each step.Results: For example problems of quantitative photoacoustic tomography and ultrasound-modulated optical tomography, we demonstrate that solutions are attainable using a total computational expense that is comparable to (or less than) that which is required for a single high-accuracy forward run of the same Monte Carlo model.Conclusions: This approach demonstrates significant computational savings when approaching the full nonlinear inverse problem of optical property estimation using stochastic methods

    On the inverse problem in optical coherence tomography

    Get PDF
    We examine the inverse problem of retrieving sample refractive index information in the context of optical coherence tomography. Using two separate approaches, we discuss the limitations of the inverse problem which lead to it being ill-posed, primarily as a consequence of the limited viewing angles available in the reflection geometry. This is first considered from the theoretical point of view of diffraction tomography under a weak scattering approximation. We then investigate the full non-linear inverse problem using a variational approach. This presents another illustration of the non-uniqueness of the solution, and shows that even the non-linear (strongly scattering) scenario suffers a similar fate as the linear problem, with the observable spatial Fourier components of the sample occupying a limited support. Through examples we demonstrate how the solutions to the inverse problem compare when using the variational and diffraction-tomography approaches

    Fabrication of High-Aspect Ratio Nanogratings for Phase-based X-ray Imaging

    Get PDF
    Diffractive optical elements such as periodic gratings are fundamental devices in X-ray imaging - a technique that medical, material science and security scans rely upon. Fabrication of such structures with high aspect ratios at the nanoscale creates opportunities to further advance such applications, especially in terms of relaxing X-ray source coherence requirements. This is because typical grating-based X-ray phase imaging techniques (e.g., Talbot self-imaging) require a coherence length of at least one grating period and ideally longer. In this paper, the fabrication challenges in achieving high aspect-ratio nanogratings filled with gold are addressed by a combination of laser interference and nanoimprint lithography, physical vapor deposition, metal assisted chemical etching (MACE), and electroplating. This relatively simple and cost-efficient approach is unlocked by an innovative post-MACE drying step with hexamethyldisilazane, which effectively minimizes the stiction of the nanostructures. The theoretical limits of the approach are discussed and, experimentally, X-ray nanogratings with aspect ratios >40 demonstrated. Finally, their excellent diffractive abilities are shown when exposed to a hard (12.2 keV) monochromatic x-ray beam at a synchrotron facility, and thus potential applicability in phase-based X-ray imaging.Comment: 27 pages, 5 figures in main text, plus supporting informatio

    Faecal immunochemical tests (FIT) can help to rule out colorectal cancer in patients presenting in primary care with lower abdominal symptoms:a systematic review conducted to inform new NICE DG30 diagnostic guidance

    Get PDF
    __Background:__ This study has attempted to assess the effectiveness of quantitative faecal immunochemical tests (FIT) for triage of people presenting with lower abdominal symptoms, where a referral to secondary care for investigation of suspected colorectal cancer (CRC) is being considered, particularly when the 2-week criteria are not met. __Methods:__ We conducted a systematic review following published guidelines for systematic reviews of diagnostic tests. Twenty-one resources were searched up until March 2016. Summary estimates were calculated using a bivariate model or a random-effects logistic regression model. __Results:__ Nine studies are included in this review. One additional study, included in our systematic review, was provided as 'academic in confidence' and cannot be described herein. When FIT was based on a single faecal sample and a cut-off of 10 μg Hb/g faeces, sensitivity estimates indicated that a negative result using either the OC-Sensor or HM-JACKarc may be adequate to rule out nearly all CRC; the summary estimate of sensitivity for the OC-Sensor was 92.1%, based on four studies, and the only study of HM-JACKarc to assess the 10 μg Hb/g faeces cut-off reported a sensitivity of 100%. The corresponding specificity estimates were 85.8% (95% CI 78.3-91.0%) and 76.6%, respectively. When the diagnostic criterion was changed to include lower grades of neoplasia, i.e. the target condition included higher risk adenoma (HRA) as well as CRC, the rule-out performance of both FIT assays was reduced. __Conclusions:__ There is evidence to suggest that triage using FIT at a cut-off around 10 μg Hb/g faeces has the potential to correctly rule out CRC and avoid colonoscopy in 75-80% of symptomatic patients. Systematic review registration: PROSPERO 4201603772

    Factors Associated with Revision Surgery after Internal Fixation of Hip Fractures

    Get PDF
    Background: Femoral neck fractures are associated with high rates of revision surgery after management with internal fixation. Using data from the Fixation using Alternative Implants for the Treatment of Hip fractures (FAITH) trial evaluating methods of internal fixation in patients with femoral neck fractures, we investigated associations between baseline and surgical factors and the need for revision surgery to promote healing, relieve pain, treat infection or improve function over 24 months postsurgery. Additionally, we investigated factors associated with (1) hardware removal and (2) implant exchange from cancellous screws (CS) or sliding hip screw (SHS) to total hip arthroplasty, hemiarthroplasty, or another internal fixation device. Methods: We identified 15 potential factors a priori that may be associated with revision surgery, 7 with hardware removal, and 14 with implant exchange. We used multivariable Cox proportional hazards analyses in our investigation. Results: Factors associated with increased risk of revision surgery included: female sex, [hazard ratio (HR) 1.79, 95% confidence interval (CI) 1.25-2.50; P = 0.001], higher body mass index (fo

    Measurement of the W boson polarisation in ttˉt\bar{t} events from pp collisions at s\sqrt{s} = 8 TeV in the lepton + jets channel with ATLAS

    Get PDF

    Measurement of jet fragmentation in Pb+Pb and pppp collisions at sNN=2.76\sqrt{{s_\mathrm{NN}}} = 2.76 TeV with the ATLAS detector at the LHC

    Get PDF

    Search for new phenomena in events containing a same-flavour opposite-sign dilepton pair, jets, and large missing transverse momentum in s=\sqrt{s}= 13 pppp collisions with the ATLAS detector

    Get PDF
    corecore