5 research outputs found

    Magnetic Field and Radiation Tests of a Programmable Delay Line

    No full text
    Programmable Delay Lines (PDLs) are widely used in trigger systems. We performed tests under radiation and magnetic field for the chip 3D3418-0.25, to be used in the ALICE-TOF trigger system. The tests showed that this chip can comfortably operate in a 0.6 T magnetic field and tolerate a dose larger than 446 G

    Operation of the Multigap Resistive Plate Chamber using a gas mixture free of flammable components

    No full text
    We have investigated the operation of the multigap resistive plate chamber (MRPC) for the ALICE-TOF system with a gas mixture free of flammable components. Two different gas mixtures, with and without iso-C4H10 have been used to measure the performance of the MRPC. The efficiency, time resolution, total charge, and the fast to total charge ratio have been found to be comparabl

    Latest results on the performance of the multigap resistive plate chamber used for the ALICE TOF

    No full text
    For the identification of particles in the momentum range 0.5-2.5GeV/c, the ALICE experiment uses a Time Of Flight array consisting of Multigap Resistive Plate Chambers (MRPC) in the form of long strips. The design of the detector elements is as follows : double stack MRPCs with glass resistive plates and 5 gas gaps of 250 mum per stack. The latest results on the performance of these MRPCs are presented. Typical values of time resolution a are better than 50 ps, with an efficiency of 99.9% and a long, more than 1.5 kV, streamer-free plateau
    corecore