24 research outputs found

    一般外科手術における術後肺血栓塞栓症予防のための周術期管理

    No full text

    Omental flap transposition for inferior vena cava filter penetration

    No full text
    A 40-year-old woman presented with uterine malignancy, deep vein thrombosis, and nonmassive pulmonary embolism in both lungs. Gunter-tulip filter was inserted, because she had severe genital bleeding, which is one of the contraindications to anticoagulation therapy. Total hysterectomy was conducted and anticoagulation therapy was started afterward. The thrombus worsened perioperatively, and the filter could not be retrieved. Since there was lymph node recurrence, the second time operation was performed. During operation, the struts were found to be penetrating the inferior vena cava. Omental flap was used to cover the struts, and no associated complications occurred after operation

    A case of an atrial tachycardia originating from an occluded coronary sinus ostium with a persistent left superior vena cava

    No full text
    We present a case of a 37-year-old female who complained of frequent palpitations caused by an atrial tachycardia and atrial premature contractions. Angiography revealed that the coronary sinus was occluded at the ostium and connected to a persistent left superior vena cava. An electrophysiological study and three-dimensional mapping revealed that the origin of the atrial tachycardia and atrial premature contractions was at the coronary sinus ostium in the right atrium. After repeat applications of radiofrequency energy at that site, no further atrial tachycardia or atrial premature contractions were induced by atrial burst pacing. To the best of our knowledge, this is the first report of an atrial tachycardia originating from an occluded coronary sinus ostium

    Comparative study of sub-second temporal resolution 4D-MRI and 4D-CT for target motion assessment in a phantom model

    No full text
    Abstract To develop and investigate the feasibility of sub-second temporal resolution volumetric T1-weighted four-dimensional (4D-) MRI in comparison with 4D-CT for respiratory-correlated motion assessment using an MRI/CT-compatible phantom. Sub-second high temporal resolution (0.5 s) gradient-echo T1-weighted 4D-MRI was developed using a volumetric acquisition scheme with compressed sensing. An MRI/CT-compatible motion phantom (simulated liver tumor) with three sinusoidal movements of amplitudes and two respiratory patterns was introduced and imaged with 4D-MRI and 4D-CT to investigate the geometric accuracy of the target movement. The geometric accuracy, including centroid position, volume, similarity index of dice similarity coefficient (DSC), and Hausdorff distance (HD), was systematically evaluated. Proposed 4D-MRI achieved a similar geometric accuracy compared with 4D-CT regarding the centroid position, volume, and similarity index. The observed position differences of the absolute average centroid were within 0.08 cm in 4D-MRI and 0.03 cm in 4D-CT, less than the 1-pixel resolution for each modality. The observed volume difference in 4D-MRI/4D-CT was within 0.73 cm3 (4.5%)/0.29 cm3 (2.1%) for a large target and 0.06 cm3 (11.3%)/0.04 cm3 (11.6%) for a small target. The observed DSC values for 4D-MRI/4D-CT were at least 0.93/0.95 for the large target and 0.83/0.84 for the small target. The maximum HD values were 0.25 cm/0.31 cm for the large target and 0.21 cm/0.15 cm for the small target. Although 4D-CT potentially exhibit superior numerical accuracy in phantom studies, the proposed high temporal resolution 4D-MRI demonstrates sub-millimetre geometric accuracy comparable to that of 4D-CT. These findings suggest that the 4D-MRI technique is a viable option for characterizing motion and generating phase-dependent internal target volumes within the realm of radiotherapy
    corecore